Page 2 :
II, , DETAILED CONTENTS, , KERALA PANCHAYAT BUILDING RULES, 2019, TABLES, 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, , NOC/ CLEARANCE/ CONSENT/ CONCURRENCE, COLOUR SCHEME, CLEARANCE FROM OVERHEAD ELECTRIC LINES, DISTANCE BETWEEN PLOT BOUNDARY ABUTTING, THE STREET AND BUILDING, YARDS FOR BUILDINGS UNDER DIFFERENT, OCCUPANCIES, PROJECTIONS PERMISSIBLE, COVERAGE AND FLOOR SPACE INDEX (F.S.I), ACCESS FOR GROUP A1, A2, B, C, E AND F, OCCUPANCIES, ACCESS FOR GROUP D, G1, G2, H, I, AND J, OCCUPANCIES, OFF-STREET PARKING SPACE FOR, APARTMENTS/FLATS UNDER GROUP-A1, OFF-STREET PARKING SPACE FOR OCCUPANCIES, OTHER THAN GROUP-A1, APPROVALS FROM TOWN AND COUNTRY, PLANNING DEPARTMENT, WIDTH OF STREET (LAND SUBDIVISION), OCCUPANT LOAD FOR CALCULATING SANITATION, REQUIREMENTS, SANITATION REQUIREMENTS, SANITATION REQUIREMENTS FOR MEDICAL /, HOSPITAL OCCUPANCY, OCCUPANTS PER UNIT EXIT WIDTH, OCCUPANT LOAD, SIZE OF AIR SHAFT, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 15, 24, 42, 43, 50, 51, 53, 55, 55, 58, 58, 61, 62, 66, 66, 68, 72, 72, 74
Page 3 :
III, Rules, , Contents, , I, 1, 2, 3, , DEFINITIONS, Short title, applicability and commencement, Definitions, Applicability, CHAPTER II, DRAWINGS, PERMITS AND OCCUPANCY, CERTIFICATES, Essentiality of permit, Application for Development / building permit, Plans to be submitted, Certain operational constructions by Government to be, exempted from these rules, Permit not necessary for certain works, Approval of site and plans and issue of permit, Approval of site and plans and issue of permit where, excavations to a depth of more than 1.5 metres is, involved, Grounds on which approval of site or permission to, construct or reconstruct building may be rejected, Period within which approval or disapproval shall be, intimated, Period within which Secretary is to grant or refuse, permission to execute work, Reference to Village Panchayat where the Secretary, delays to grant or refuse or approve permit, Extension and renewal of period of permits, Suspension and Revocation of permit, Duties and responsibilities of the owner or developer, Responsibilities and functions of registered Architects,, etc., Transfer of plots to be intimated, Completion certificate, development certificate and, occupancy certificate, Post Occupancy Audit, , II, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, , CHAPTER I, , Page, No., 2-14, 2, 2, 12, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 1441, 14, 14, 20, 25, 26, 26, 27, 29, 29, 30, 30, 31, 33, 33, 38, 39, 40, 41
Page 4 :
IV, III, 22, 23, 24, IV, 25, 26, 27, 28, 29, 30, 31, V, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, , CHAPTER III, GENERAL PROVISIONS REGARDING SITE AND, BUILDING REQUIREMENTS, General requirements regarding plot, Prohibition for construction abutting public roads, Height of buildings, CHAPTER IV, OCCUPANCY, Occupancy of buildings, Exterior and interior open air spaces, Coverage and Floor Space Index, Access, Parking, loading and unloading spaces, Approval for layout of buildings and usage of plot, Land subdivision and plot development, CHAPTER V, PARTS OF BUILDING, Mezzanine floor, Height of room, Sanitation Facilities, Staircases and fire escape staircases, Travel distance to emergency exit, Exit width, Doorways, Corridor, Verandas and passageways, Lift / Escalator, Lighting and Ventilation, Provisions for Differently-abled, Elderly and Children, Other provisions for Apartment buildings under Group, A1 Residential occupancy, Other provisions for Group D Assembly Occupancy, buildings, Other provisions regarding Group G1 and G2 Industrial, occupancy buildings, , 4144, 41, 43, 44, 4565, 45, 49, 52, 55, 58, 61, 62, 6579, 65, 65, 66, 70, 71, 71, 73, 73, 73, 74, 74, 76, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 77, 78
Page 5 :
V, 46, 47, 48, VI, 49.1, 49.2, 50, VII, 51, VIII, 52, 53, 54, 55, 56, IX, 57, 58, 59, 60, 61, , Other provisions regarding Group H Storage occupancy, buildings, Other provisions regarding Fuel filling stations under, Group I Hazardous occupancy, Certain Buildings exempted, CHAPTER VI, HUTS AND BUILDINGS IN SMALL PLOTS, Special provisions for Huts and certain other, constructions, Special provisions for Tribal colonies, Special provisions for constructions in small plots, CHAPTER VII, ROW BUILDINGS, Special provisions for Row buildings, CHAPTER VIII, BUILDING CONSTRUCTION UNDER APPROVED, SCHEMES, Provision for construction under approved schemes, Area and floor restrictions, Set back provisions, Certain provisions not to apply, Application for permit and its disposal, CHAPTER IX, SPECIAL PROVISIONS FOR LARGE-SCALE, DEVELOPMENT PROJECTS APPROVED BY, GOVERNMENT, Applicability of the Provisions, Constitution and functioning of the committee, Provision for supporting infrastructure, Memorandum of Understanding, Other provisions, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 78, 79, 79, 7981, 79, 80, 81, 82, 82, 8284, 82, 83, 83, 83, 83, 8485, 84, 84, 85, 85, 85
Page 6 :
VI, , XII, , CHAPTER X, CONSTRUCTION IN PLOTS PART OF WHICH, HAVE BEEN SURRENDERED FREE OF COST, FOR ROAD DEVELOPMENT, Provisions to apply as modified for constructions in, certain plots, Usage of plot, Other provisions, Constitution of Special Committees, Buildings part of which has been demolished for the, purposes specified in rule 62, CHAPTER XI, ACCESSORY BUILDINGS AND SHED, Certain buildings and sheds exempted, Temporary hut or shed, CHAPTER XII, WALL AND FENCE, , 69, 70, 71, , Prohibition of commencement of work, Submission and disposal of application, Completion report, , XIII, , SPECIAL PROVISIONS FOR CERTAIN, CONSTRUCTIONS, Special provisions for addition etc. over buildings, existing on the 30th March 2000, Conversion of roof shutters etc. of buildings existing, before the commencement of these rules, Construction of additional sheet/ tiles roof over the, terrace of certain single family residential buildings, CHAPTER XIV, , X, 62, 63, 64, 65, 66, XI, 67, 68, , 72, 73, 74, XIV, 75, 76, , CHAPTER XIII, , WELLS, RAIN WATER HARVESTING, Wells, Rain water Harvesting, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 8589, 85, 87, 87, 88, 89, 90, 90, 90, 9091, 90, 91, 91, 9194, 91, 93, 93, 9497, 94, 95
Page 7 :
VII, CHAPTER XV, , XV, , XVI, , SOLAR ASSISTED WATER HEATING /, LIGHTING SYSTEM, Rooftop Solar Energy Installations, Solar assisted water heating system in buildings, CHAPTER XVI, WASTE DISPOSAL, , 79, , Waste management, , XVII, , CHAPTER XVII, SAFETY PROVISIONS FOR HIGH RISE BUILDINGS, , 9899, 98, , 80, 81, 82, , High rise building, Safety provisions, Display of the details of the permit etc., , 99103, 99, 99, 102, , XVIII, , TELECOMMUNICATION TOWERS, , 83, 84, 85, 86, 87, 88, , Essentiality of permit, Special provisions, Damage and liability, Site approval etc., Submission of application and its disposal, Completion Certificate, CHAPTER XIX, ACTION AGAINST UNAUTHORISED, CONSTRUCTIONS, Deviation during construction and power of Secretary to, require alteration in work, Demolition or alteration of work unlawfully commenced,, carried on or completed, Order of stoppage of building works in certain cases, , 77, 78, , XIX, 89, 90, 91, , CHAPTER XVIII, , 9796, 97, 98, , 103107, 103, 103, 105, 105, 105, 106, 107110, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 107, 108, 109
Page 8 :
VIII, CHAPTER XX, , XX, 92, 93, 94, 95, 96, XXI, 97, 98, 99, 100, 101, 102, XXII, 103, XXIII, 104, 105, 106, 107, 108, 109, I, II, III, , REGULARISATION OF UN PERMITTED, CONSTRUCTIONS AND DEVIATIONS, Power of the Secretary to regularise certain, constructions, Submission of application and procedure for its disposal, Application fee, Decision to be intimated, Demolition of buildings not regularized, CHAPTER XXI, REGISTRATION OF ARCHITECTS, ENGINEERS,, TOWN PLANNERS ETC., Plans and drawings to be prepared and signed by, Architect, etc., Registering authority, Application and procedure for registration, Qualification for registration, Registration in more than one category, Certificate of Professionals for KSECBC, CHAPTER XXII, THE KERALA URBAN ARTS COMMISSION, Constitution of the Commission, CHAPTER XXIII, VIGILANCE, DANGEROUS AND DEFECTIVE WORKS,, APPEAL, ETC., Secretary to submit report, Vigilance, Stoppage of dangerous or defective works, Penalty for unlawful building, Appeal, Removal of doubts, etc., SCHEDULES, Application Fee, Permit Fee, Scrutiny fee for Layout approval, , 110111, 110, 110, 111, 111, 111, 112114, 112, 112, 112, 113, 113, 114, 115, 115, 115118, 115, 116, 116, 116, 117, 118, 174175, 177, 178, 179, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA)
Page 9 :
IX, APPENDICES/ FORMATS, A1, , Application for Permit/ Regularisation, , A2, , Application for construction in plots parts of which have, been surrendered free of cost for Road development, , A3, , [See rules 5(1)(b), 75(1), 87(1), and 93(1)], , 119, , [See rule 62(1)], , 125, , B1, B2, C, D, E1, , Application form for Permit for Development/, Redevelopment of land [See rule 5(1)(a)], Application for Layout approval and usage of plot /, Concurrence [See rule 5(6)(2)], Development permit [See rule 6(17)], Site approval and Building permit [See rules 6(17) & 9(4)], Concurrence/ Usage of plot [See rule 10(7)], Notice regarding the Intention to start work[See rule17(5)(d)], Completion Certificate by the Owner, , E2, , Partial Completion Certificate by the Owner, , E3, , Completion Certificate by Institution, Architect, Engineer,, Etc. [See rules 20(1) & 88(1)], Partial Completion Certificate by Institution, Architect,, Engineer, Etc. [See rule 20(4)], Development Certificate [See rules 17(5)(f) & 20(2)], Occupancy Certificate or Use Certificate, , A4, , [See rules 17(5)(e), 20(1) & 88(1)], , [See rules 17(5)(e), 20(4)], , E4, F1, F2, G1, G2, H1-A, H1-B, H2, H3, I, , 119176, , [See rules 17(5)(f), 20(3) & 88(2)], , Regularisation Order [See rule 95(3)], Register for Regularised construction [See rule 95(3)], Application for registration as Architect/ Engineer/ Town, planner/ Supervisor etc. [See rule 99(1)], Application for registration as Institution (Architecture)/, Institution (Civil Engineering). [See rule 99(1)], Qualification and function of Architect, Engineer etc., [See rules 88(11) & 100], , Certificate of registration [See rule 99(4)], Application for renovation without involving additional, built-up area or structural alterations of existing buildings, for religious purpose or places of worship, [See rule 5(4)(Note ii)], , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 127, 128, 134, 135, 137, 138, 139, 140, 141, 142, 143, 144, 145, 147, 148, 150, 152, 160, 161
Page 10 :
X, J1, J2, (K)(a), (K)(b), , (K)(d), L, M, , Certificate (To be recorded in the drawings) [See rule 6(3)], Certificate (To be recorded in the drawings) [See rule 9(2)}, Approval forms for KSECBC [See rule 5(5)(2)], Form IA. Undertaking by Owner for construction of, ECBC compliant building. [See rule 5(5)(2)], Form II. Certificate from KSECBC licensed engineer/, BEE certified building energy auditor to be enclosed with, the application for building permit for KSECBC compliant, building. [See rule 5(5)(2)], Form III. Notice of completion [See rule 17(19)], Self declaration form [See rule 5(4)], Criteria for considering an application for exemption, , N, , Application for exemption from Building Rules, , (K)(c), , 163, 164, 165, 166, , 167, 168, 169, , [See Rule 3(5)], , 171, , [See Rule 3(5)], , 174, , FEELA, , www.feelaonline.com, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA)
Page 11 :
THE KERALA PANCHAYAT, BUILDING RULES, 2019, , GOVERNMENT OF KERALA, Local Self Government (RD) Department, G.O.(P) No.78/2019/LSGD., , NOTIFICATION, , Dated, Thiruvananthapuram, 2nd November, 2019., 16th Thulam, 1195., , S. R. O. No. 829/2019, , In exercise of the powers conferred by sections 235A, 235B, 235F, 235P, 235W read with, section 254 of the Kerala Panchayat Raj Act, 1994 (13 of 1994) and in supersession of the Kerala, Panchayat Building Rules, 2011 issued under G.O. (Ms.) No 41/2011/LSGD. dated 14th February,, 2011 and published as S.R.O. No. 127/2011 in Kerala Gazette Extraordinary No. 351 dated 14th, February,2011, the Government of Kerala hereby make the following rules, namely:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 1
Page 12 :
2, , KERALA PANCHAYAT BUILDING RULES 2019, CHAPTER I, DEFINITIONS, , 1. Short title, applicability and commencement.- (1) These rules may be called the Kerala, Panchayat Building Rules, 2019., (2), They shall apply to area under all Village Panchayats in the State., (3), , They shall come into force at once., , 2. Definitions - (1) In these rules, unless the context otherwise requires,(a), , (b), (c), , ‘access’ means a clear approach to a plot or a building;, , ‘accessory building’ means a building separated from the main building on a plot, and, containing one or more accessory uses;, , ‘accessory use’ means any use of the premises, subordinate to the principal use, and, customarily incidental to the principal use;, , (d) 'Act' means the Kerala Panchayat Raj Act, 1994 (20 of 1994);, , (e) ‘advertising sign’ means any surface or structure with characters, letters or illustrations, applied thereto and displayed in any manner whatsoever outdoors for the purpose of, advertising or giving information or to attract the public to any place, person, public, performance, article, or merchandise, and which surface or structure is attached to, forms, part of, or is connected with any building, or is fixed to a tree or to the ground or to any, pole, screen, fence or hoarding or displayed in space, or in or over any water body., (f) ‘altération’ means a structural change, such as an addition to the area or height, or, addition of floor / floors or mezzanine floors within any existing floor height or change, of existing floor or changing the roof to concrete slab or reconstruction of existing walls, or construction of concrete beam and columns amounting to structural change or, construction of internal walls for sub dividing the existing rooms with the intention of, changing the use of rooms which amounts to change in occupancy group of the building, under these rules or closing of any required means of ingress or egress to the building;, (g) 'apartment' means a building, accommodating more than two dwelling units for, residential purpose. This word is synonymous to ‘residential flat’., (h) 'appendix' means the appendix to these rules;, , (i) 'approved plan' means the set of drawings and statements submitted under these rules for, obtaining development permit or building permit and duly approved by the Secretary;, , (j) ‘assembly building’ means a building or a floor or part of a floor of a building used for, gathering of persons for the purposes of amusement, deliberation or entertainment but, does not include multiplexes., (k) ‘balcony’ means a horizontal projection, including a hand rail, or balustrade to serve as, passage or sitting out place;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 2
Page 13 :
3, , KERALA PANCHAYAT BUILDING RULES 2019, (l) ‘Basement floor’ means any lower storey of a building partially or fully below the lowest, contiguous proposed ground level provided that, the part of such storey above ground, level shall not exceed 75 centimeters. This word is synonymous with ‘cellar’., (m) 'bathroom' means a room or cubicle for bathing;, , (n) ‘building’ means any structure for whatsoever purpose and of whatsoever materials, constructed and every part thereof whether used for human habitation or not and includes, foundation, plinth, walls, floors, roofs, chimneys, plumbing and building services, fixed, platforms, verandah, balcony, cornice or projection, part of a building or anything affixed, thereto or any wall enclosing or intended to enclose any land or space and signs and, outdoor display structures, tanks constructed or fixed for storage of chemicals in any, form and for storage of water, effluent, swimming pool, ponds etc.,, (o) ‘building line’ means the line up to which the plinth of a building adjoining a street or an, extension of a street or a future street may lawfully extend. It includes the lines, prescribed, if any, in any town planning scheme in force in the area beyond which no, portion of the building may extend except as prescribed in these rules. The building line, may change from time to time as decided by the authority., (p) ‘Built- up area’ means the total area covered by the building at all floor levels. It shall, also include area of mezzanine floor, galleries, barsati and pent house at terrace level;, , (q) Category –I Village Panchayat means a Village Panchayat notified as Category I Village, Panchayat by the Government under sub-rule (5) of rule 3;, Category –II Village Panchayat means a Village Panchayat notified as Category—II, Village Panchayat by the Government under sub-rule (5) of rule 3;, (r) 'ceiling' means the internal roof/lining of any room; in case there is no such lining, the, roof membrane shall constitute the ceiling;, (s) 'Chief Town Planner' means the Chief Town Planner to the Government of Kerala;, (t) 'chimney' means an upright shaft containing and encasing one or more flues;, , (u) ‘cladding’ means those components of a building which are exposed to the outdoor and, indoor environment and are intended to provide protection against wind, vapor and heat;, , (v) ‘connected load’ means sum of the maximum amount of wattage that is allocated to all, applicants or owner of a building or part of a building, who have sought electricity, connection for the completed buildings or part thereof;, (w) ‘contract demand’ means the demand (load in terms of KVA) based on the requirement, between the building owner and power supplier;, , (x) ‘conversion’ means the change from one occupancy to another occupancy or any change, in building structure or part thereof resulting in a change of space and use requiring, additional occupancy certificate., (y) ‘corner plot’ means a plot abutting two or more intersecting streets., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 3
Page 14 :
4, , KERALA PANCHAYAT BUILDING RULES 2019, (z) 'corridor' means an exit serving as a passageway communicating with separate rooms or, with different parts of a building or with different buildings;, , (aa) ‘Covered area’ means the ground area covered by the building and is synonymous to, area of the building foot print. It shall include covered parking. It does not include the, spaces covered by :(i), , Garden, rockery, well and well structures, plant, nursery, water tank, swimming, pool (if uncovered), platform around a tree, tank, fountain bench and like:, (ii) drainage, culvert, conduit, catch pit, gully pit, drainage chamber, gutter and the, like:, (iii) flight of steps and ramps all open to sky, cantilevered car porch, compound, wall, gate, slide, swing, areas covered by sunshade and the like., (iv) storeys fully below the ground level, , (ab) ‘coverage’ means the percentage of covered area with respect to the plot area., , (ac)‘Cul-de-sac’ means a street with dead end having adequate maneuvering space facility, for vehicles., (ad) ‘Developer’ means any individual or group of individuals or any firm (by whatever, name called) who undertakes any building activity including construction,, reconstruction, repairs, additions or alterations of buildings or development or, redevelopment of land on behalf of the owner or by himself who has obtained permit, under the provisions of these rule, through an agreement executed between them., , (ae) 'development of land' means any material change on the use of land other than for, agricultural purpose brought about or intended to be brought about by filling up of the, land or changing from the existing former use of the land, layout of streets and foot, paths, provision of water supply, sewerage, drainage, electrification, landscaping, subdivision of land for residential plots or for other uses including layout of internal streets,, developing parks, play grounds and social amenities of the like, but does not include, legal partitioning of family property among heirs., , (af) ‘Development plan’ means the plan(s)/scheme(s) to any area under Town and Country, Planning legislation in force in the state (This word is synonymous with Town Planning, schemes);, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 4
Page 15 :
5, , KERALA PANCHAYAT BUILDING RULES 2019, (ag) 'double frontage plot ' means plot having a frontage on the two streets other than a corner, plot;, , (ah) 'drain' means a sewer, pipe, ditch, channel and any other device for carrying of sewage,, offensive matter, polluted water, sullage, waste water, rain water or sub-soil water and, any ejectors, compressed air mains, sealed sewage mains and special machinery or, apparatus for raising, collecting, expelling or removing sewage or offensive matter to, the sewage outfall;, (ai) 'drainage' means the removal of any liquid by a system constructed for the purpose;, , (aj) 'dwelling' means a building or a portion thereof which is designed or used wholly or, principally for residential purposes;, , (ak)'dwelling unit' means a room or suites of rooms designed and intended for habitation by, an individual or household in which facilities for cooking may or may not be provided;, (al) ‘escalator’ means a moving staircase consisting of an endlessly circulating belt of steps, driven by a motor which conveys people between floors of a building., , (am) 'exit' means a passage, channel or means of egress from any building, storey or floor to, a street or other open space of safety;, , (an) 'external wall' means an outer wall of a building; it also means a wall abutting on an, interior open space of any building;, (ao) 'factory' means any premises including the precincts thereof used or proposed to be, used for any purpose as defined under the Factories Act, 1948 (Act 63 of 1948) and, which comes under the purview of the said Act;, , (ap) 'family' means a group of individuals normally related in blood or connected by, marriage living together as a single house-keeping unit and having common kitchen, arrangements; customary resident domestic servants shall be considered as adjunct to, the term ‘family';, (aq) 'floor' means the lower surface in a storey on which one normally walks in a building., The general term 'floor' unless otherwise specifically mentioned, shall not refer to a, mezzanine floor;, , Note:-The sequential number of floor shall be determined by its relative position with, respect to the Ground floor. The floors above the ground floor shall be called in, sequence as First floor, Second floor, Third floor etc with number increasing upwards, and the floors below the ground floor shall be called in sequence as Basement floor-1,, Basement floor-2, Basement floor-3 etc with number increasing downwards., (ar) ‘floor space index (F.S.I.)’ means the quotient obtained by dividing the total built up, area by the area of the plot.(This word is synonymous with FAR), F.S.I. = Total built-up area, Plot area, (as) 'flue' means a confined space or a duct for the outflow of smoke and waste gases, produced by a fire, a gas heater, other fuel burning installation any product of, combustion or resulting from the operation of any heat producing appliance or, equipment employing solid, liquid or gaseous fuel, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 5
Page 16 :
6, , KERALA PANCHAYAT BUILDING RULES 2019, (at) ‘frontage’ means side or part of a side of a plot which abuts a street;, , (au) 'front yard' means an open space extending laterally along the front side (main entrance, side of ground floor) of a building and forming part of the plot;, Note: - Where more than one entrances to a building are provided at the ground floor, the, entrance giving access to the major portion of the ground floor shall be considered as, the main entrance;, , (av) 'gallery' means an intermediate floor or platform projecting from a wall of an, auditorium or a hall providing extra floor area, additional seating accommodation, etc.;, (aw) 'garage' means a building or portion thereof, used or intended to be used for the, shelter, storage or repair of any mechanically propelled vehicle;, (ax) 'Government' means the Central or State Government, , (ay) ‘Government Approved Private Information Technology Building’ means any, Information Technology Building constructed in the private sector and approved by the, Information Technology Department of Government of Kerala, which does not fall, under the category of Government Approved Private Information Technology Park and, Government Owned Information Technology Park;, (az) ‘Government Approved Private Information Technology Park’ means any Information, Technology Park promoted by a private entity, which is approved by the Information, Technology Department of Government of Kerala;, , (ba) ‘Government Owned Information Technology Park’ means any Information, Technology Park promoted by an entity of the State Government or Central, Government, which is approved by the Information Technology Department of, Government of Kerala;, , (bb) ‘Green building’ means the one which uses less water, optimises energy efficiency,, conserves natural resources, generate less waste and provide healthier spaces for, occupants, as compared to a conventional building as specified by Indian Green, Building Council;, (bc) ‘Ground floor’ means:, , (i) the lowest floor of a building in the case of the building without basement, floor(s) and;, , (ii) the floor above the uppermost basement floor, in the case of building with, basement floor(s)., (bd)‘habitable room’ means a room occupied or designed for occupancy by one or more, persons for study, prayer, living, sleeping, eating, kitchen if it is used as dining room,, but not including bathrooms, water-closet compartments, laundries, serving and, storage pantries, corridors, attics and spaces that are not used frequently or during, extended periods, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 6
Page 17 :
7, , KERALA PANCHAYAT BUILDING RULES 2019, (be)'head room' means the clear vertical distance measured from the finished floor surface, to the finished ceiling surface; where a finished ceiling is not provided, the underside, of the joists or beams or tie beams shall determine the upper point of measurement;, (bf) ‘height of building’ means the vertical distance measured from the average proposed, ground level contiguous to the building;, (i), , (ii), , in the case of flat roofs, to the highest point of the flat roof;, , in the case of pitched roofs and gabled roofs, to the midpoint between the eves, level and the ridge;, , (iii) in the case of domed roofs, to the highest point of the dome;, , provided that architectural features appurtenant roof structures like staircase tower,, overhead tanks, air-conditioning plant rooms, lift rooms, cellular, telecommunication equipments, tower structures, chimneys, rooftop helipad,, open swimming pools, parapet walls and similar roof structures other than pent, houses shall not be included in the height of the building., Note:- for arriving at the average proposed ground level, the average of the lowest, proposed ground level and the highest proposed ground level contiguous to, the building shall be taken., , (bg) 'height of room' means the vertical distance between the floor and the lowest point, excluding beam and column on the ceiling of the room;, (bh) 'hut' means any building constructed principally of wood, mud, leaves, grass, thatch or, such easily perishable material, , (bi) ‘Information Technology Building’ means a building occupied by industries, any other, business establishments, whose functional activities are in the field of Information, Technology, Information Technology Enabled Services (IT/ITES) and, Communications Technology of the total built up area in such buildings, at least 70%, of the area should be earmarked for this purpose and the remaining may be utilized for, supporting activities like restaurants, food courts, meeting rooms, guest houses,, recreational facilities;, , (bj) ‘Information Technology Park’ means an integrated township, which may contain, Information Technology Buildings, as well as other buildings. The Information, Technology Buildings in the Information Technology Park shall be constructed for the, purpose of carrying out the activities set out in clause (bi) for Information Technology, Buildings and the remaining buildings in the Information Technology Park are meant, to play a complimentary role, supporting the activities in the Information Technology, Buildings. In the Information Technology Park, 70% of the land area is to be set aside, for the construction of Information Technology Buildings and the remaining land area, may be utilised for all the supporting activities. The buildings for the supporting, activities may include residential buildings, recreational facilities, educational, facilities, convention centres, hospitals, hotels and other social infrastructure meant to, support the activities in the Information Technology Buildings and Information, Technology Parks;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 7
Page 18 :
8, , KERALA PANCHAYAT BUILDING RULES 2019, (bk) ‘interior plot’ means a plot, access to which is by a passage from a street whether such, passage forms part of the plot or not;, , (bl) ‘Certified Energy Auditor (Building)’ means a person who fulfills the eligibility, criteria specified in the Energy Conservation (Minimum qualification for Energy, Auditors and Energy Managers) Rules, 2006 and has qualified National Examination, for Energy Conservation Building Codes Compliance;, However, till the conduct of Certification of Certified Energy Auditor (Building), through National Examination for Energy Conservation Building Codes Compliance,, the status quo Stated in Para 3. Initiation of Construction, in the Kerala State ECBC,, 2017 shall be complied with;, , (bm) 'lift well' means the unobstructed space within an enclosure provided for the vertical, movement of the lift car and any counter weight including the lift pit and the space for, top clearance;, , (bn) 'loft' means a residual space in a pitched roof, or any similar residual space, above, normal floor level without any direct staircase leading to it which may be constructed, or adopted for storage purposes;, (bo) ‘mechanised parking’ include, parking and retrieval of vehicles by mechanical means;, , (bp) 'mezzanine floor' means an intermediate floor in any storey overhanging and, overlooking a floor beneath;, (bq) ‘multiple occupancy building’ means any building which accommodates more than, one occupancy other than Group G2, Group I and Group J as per these rules;, (br) ‘Panchayat’ means a village panchayat, a block panchayat, or a district panchayat, constituted under section 4 of the Act., , (bs) 'occupancy group' means the principal occupancy for which a plot, a building or, a part of a building is used or intended to be used; for the purposes of classification of, a plot or building according to occupancy, an occupancy shall be deemed to include, the subsidiary occupancies which are contingent upon it;, (bt) ‘open space’ means an area, forming an integral part of the plot, left open to the sky;, (bu)‘operational construction’ means a construction whether to be temporary or permanent, which is necessary for the operation, maintenance, development or execution of any of, the services essential to the life of the community as declared by the Central or State, Government from time to time;, (bv) 'owner' in respect of land or building, means the person who receives the rent for the, use of the land or building or would be entitled to do so if they were let and includes,(i) an agent or trustee who receives such rent on behalf of the owner or is connected, with any building devoted to religious or charitable purpose;, , (ii) a receiver, executor or administrator or a manager appointed by any court of, competent jurisdiction to have the charge of or to exercise the rights of the owner;, (iii) mortgagee in possession; and, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 8
Page 19 :
9, , KERALA PANCHAYAT BUILDING RULES 2019, (iv) a lessee in possession;, (bw) ‘parapet’ means a low wall not more than 1.2 m in height built along the edge of a, roof or a floor;, , (bx) ‘parking building’ or ‘parking plaza’ means an independent building used exclusively, for off-street car parking;, (by) ‘parking space’ means an area enclosed or unenclosed, sufficient in size to park, vehicles, together with a driveway connecting the parking space with a street and, permitting ingress and egress of vehicles;, (bz) 'passage way' means a means of access;, , (ca) 'pathway' means an approach constructed with materials, such as bricks, concrete,, stone, asphalt or the like;, (cb) 'permit' means a permission or authorisation in writing by the Secretary to carry out, work;, , (cc) ‘Persons with disability’ means, persons with disability as defined in clause (1) of, section 2 of the Persons with Disabilities (Equal Opportunities, Protection of Rights, and Full Participation) Act, 1995 (1of 1996);, (cd) 'plinth' means the portion of a structure between the surface of the surrounding, ground and surface of the floor, first above the ground;, , (ce) 'plinth area' means area of the building at the plinth level, and shall not include the, area of open porch (not enclosed by wall), uncovered staircase;, (cf) ‘plot’ means a parcel or piece of land enclosed by definite boundaries as described in, the document in support of ownership of the plot;, , (cg) ‘plot area’ means the area of the land as per the records of the revenue authorities as, authenticated by a possession certificate, land tax receipt issued by the Village, Officer;, (ch) 'plot depth' means the mean horizontal distance between the front and rear plot, boundaries;, , (ci) 'porch' means a canopy supported on pillars or otherwise and used for the purpose of, pedestrian or vehicular approach to a building;, (cj) ‘rear yard’ means the open space extending laterally along the rear side of the plot and, forming part of the plot; any side yard can be interchanged with rear yard., (ck) 're-development of land' means re-developing an already developed land., , (cl) 'Registered Institution /Architect/Engineer/Town Planner/Supervisor' means an, Institution/Architect/Engineer/Town Planner/Supervisor registered or deemed to, have been registered as such under these rules;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 9
Page 20 :
10, , KERALA PANCHAYAT BUILDING RULES 2019, (cm) ‘road’ means any highway, street, lane, pathway, alley, passageway, footway or, bridge whether a thoroughfare or not, over which the public have a right of passage or, access uninterruptedly for a specified period; whether existing or proposed in a Master, Plan / Detailed Town Planning Scheme / Interim Development Order in force under, the Kerala Town and Country Planning Act, 2016 (9 of 2016);, , (cn) ‘road level’ means the officially established elevation of the centre line of the road, upon which a plot abuts and if there is no officially established elevation, the existing, elevation of the centre line of the road;, (co) ‘road width’ shall be the minimum existing width of the road at any point ., , (cp) ‘row buildings’ means buildings in a row with only front and rear open spaces with or, without interior open spaces., (cq) 'Secretary' means the Secretary of a Panchayat;, (cr) ‘section' means a Section in the Act;, , (cs) ‘Security Zone’ means any area, identified and delineated by the Home Department of, the state government as Security Zone from time to time and notified and published in, government gazette by the Local Self Government Department. For the purpose of, these rules, any area around compounds or sites which accommodate vital or strategic, installations, offices, residences, institutions, landmarks, jail compounds, monuments,, ports, shipyards, scientific and advanced research centres and the like, which in the, opinion of the government, needs special security and necessitates regulations and/or, restrictions for constructions and land developments around, can be delineated as, security zone., (ct) 'service lane' means a lane provided at the rear or side of a plot for service purposes;, , (cu) 'service station' means a place where washing, cleaning and oiling of automobile is, done without any repairing;, (cv) 'set back line' means a prescribed building line drawn with reference to the central, line or boundary of a street, on the street side of which nothing can be erected or reerected except compound wall;, , (cw) 'sewage drain' means a drain used or constructed to be used for conveying solid or, liquid waste matter, excremental or otherwise to a sewer;, (cx) 'shop' means a building or part of a building where articles or goods of any kind are, ordinarily sold. It shall not include a workshop;, (cy) ‘side yard’ means an open space extending laterally between any side of a building, and the boundary of the plot facing that side other than front and rear yard and, forming part of the plot; any side yard can be interchanged with rear yard, (cz) ‘site' means a plot and its surrounding precincts;, , (da) 'stair cover' means cabin - like structure with a covering roof over a staircase and its, landing built to enclose only the stairs for the purpose of providing protection from, weather and not used for human habitation. It is synonymous with stair cabin or, staircase room;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 10
Page 21 :
11, , KERALA PANCHAYAT BUILDING RULES 2019, (db) 'stall' means any structure other than a hut used solely for the display and sale of goods, , (dc) 'storey' means the portion of a building included between the surface of any floor and, the surface of the floor next above it, or if there be no floor above it, then the space, between any floor and the ceiling next above it;, (dd) ‘street’ means a private or a public path giving access to more than one plot or, building;, (de) 'street level' means the level at the centre line of the street, (df) 'street line' means the line defining the side limits of a street;, , (dg) 'structure' means anything that is built or constructed or building of any kind or any, piece of work artificially built up or composed of parts joined together in some, definite manner. The term structure includes ‘building';, (dh) 'sunshade’ or ‘weather shade' means a sloping or horizontal structural overhang, usually provided over openings on external walls to provide protection from sun and, rain;, , (di) 'tenement' means part of a building intended or used or likely to be used as a dwelling, unit;, (dj) 'to erect' means-, , (i) to erect a new building on any site whether previously built up or not;, , (ii) to re-erect any building of which portions above the plinth level have been, pulled down or destroyed; and, (iii) conversion from one occupancy to another;, , (dk) 'travel distance' means the distance an occupant has to travel to reach an exit;, , (dl) 'unconnected latrine' means a latrine not connected to the public sewer system, it may, be connected to a septic tank;, (dm) 'unsafe building' means building which is structurally unsafe, insanitary or not, provided with adequate means of egress or which constitute a fire hazard or are, otherwise dangerous to human life or which in relation to existing use constitute a, hazard to safety or health or public welfare, by reason of inadequate maintenance,, dilapidation or abandonment;, , (dn) 'use group' means the principal use for which a plot, a building or part of a building is, used or intended to be used;, , (do) 'verandah' means a covered area with at least one side open to the outside with the, exception of parapet, trellis, jelly or grill work on the open side;, , (dp) 'warehouse' means a building, the whole or substantial part of which is used or, intended to be used for the storage of goods whether for keeping or for sale or for any, similar purposes but does not include a store room attached and used for the proper, functioning of a shop;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 11
Page 22 :
12, , KERALA PANCHAYAT BUILDING RULES 2019, (dq) 'water closet' or 'WC' means a latrine with arrangement for flushing the pan with, water but does not include a bathroom;, (dr) 'water course' means an artificial or natural drainage canal;, , (ds) ‘width of street‘ means the right of way and includes carriageway, footpath, service, roads, flyovers, medians, road side drains, street furniture, wayside plants/trees and, the like., , (dt) 'yard' means an open space at ground level between a building and the adjoining, boundary lines of the plot unoccupied and unobstructed except by, encroachment of structures specially permitted by these rules on the same plot with a, building. All yard measurements shall be the minimum distance between the front,, rear and side yard plot boundaries, as the case may be, and the nearest point of the, building including enclosed porches; every part of a yard shall be accessible from, every part of the same yard., (2) Words and expressions used, but not defined in these rules, but defined in the, Kerala Panchayat Raj Act, 1994 (20 of 1994) shall have the same meaning, assigned to them in that Act., 3. Applicability:-These rules shall apply to:-, , (1) any public or private building as described below, namely :-, , (a) where a building is newly erected, these rules shall apply to the, designs and construction of the building;, (b) where the building is altered, these rules shall apply to the altered, portion of the building;, , (c) where the occupancy or use of building is changed, these rules shall, apply to all the parts of the building affected by the change;, (d) where addition or extension is made to a building, these rules shall, apply to the addition or extension only,, , Provided that, for calculation of Floor Space Index, coverage, required off street, parking area to be provided and width of access to the plot as well as minimum, width of the street giving access to the plot from the main street, the whole, building existing to be retained and proposed shall be taken into account;, , Provided further that the addition, extension or new building shall be permitted, only if the site and existing buildings are authorised., (2) All lands which are proposed to be developed or redeveloped for, construction of buildings., (3) Provisions in the Master Plan, Detailed Town Planning Scheme etc. shall, prevail:- Notwithstanding anything contained in these rules, provisions or, regulations in any Master Plan / Detailed Town Planning Scheme / Interim, Development Order in force under the Kerala Town and Country Planning, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 12
Page 23 :
13, , KERALA PANCHAYAT BUILDING RULES 2019, Act, 2016 (9 of 2016) shall prevail over the respective provisions of these, rules wherever such Plan/ Scheme/ Order exist., , (4) Power of the Government to relax the provisions of these rules in certain, cases:- The Government may, in conformity with the provisions of the Act, and in consultation with the Chief Town Planner, relax any building from the, provisions of these rules, when construction is made –, (a), , (b), , by Government/Local Self Government Institutions or Government, Institutions for a public purpose,, , by co-operative societies, which were set up and functioning with the, Government share and financial assistance and which come under, Group B Education and/or Group C Medical/Hospital occupancies as, provided in rule 25 of these rules exclusively for a Government, purpose. By any individual or organisation for construction of aidedschools., , (c) by any individual, group of individuals or corporate body in parcels of, land left behind after surrendering to the state government or the local, self government concerned free of cost for a public purpose with prior, approval of the state government., , (5) Power of Government to exempt buildings – The Government may in, confirmity with the provisions of the Act and in consultation with the Chief, Town Planner exempt any building from the operation of all or any of the, provisions of these rules, subject to conditions, if any, to be stipulated in the, order, granting such exemptions;, , Provided that such exemption shall be considered on individual, application as per criteria stipulated in Appendix M. The application form, in Appendix N for exemption shall be forwarded to the Government, through the Chief Town Planner with their remarks., Provided further that such exemption shall be considered only if the, individual application for exemption from these rules is forwarded to the, Government along with a chalan receipt remitting the application fee in, Government Treasury as decided by Government from time to time., , (6) Categorisation of Village Panchayat,-, , (a) The Government may, for the purpose of these Rules, by notification in, , the official Gazette, categorise the Village Panchayats into two, categories such as Category-I and Category- II., , (b) The Village Panchayat,(i), , which in the opinion of the Government has significant potential for, , urbanization and/or special characteristics which necessitate more regulatory intervention; or, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 13
Page 24 :
14, , KERALA PANCHAYAT BUILDING RULES 2019, which is either partly or fully covered by a Development Plan published or sanctioned as per, the provisions contained in the Town Planning Act in force, shall be categorised as CategoryI Village Panchayat., , which do not fall under Category-I Village Panchayat shall be categorised as Category-II, Village Panchayat., , CHAPTER II, , DRAWINGS, PERMITS AND OCCUPANCY CERTIFICATES, 4., , Essentiality of permit - (1), No person shall develop or redevelop any parcel of, land by subdividing into plots or cause the same to be done without first obtaining a, permit for each such development or redevelopment from the Secretary., (2), , (3), 5., , No person shall construct or reconstruct or make addition or extension or, alteration to any building or cause the same to be done without first obtaining a, building permit for each such work from the Secretary., No person shall change the occupancy of an existing building from one group to, another, without first obtaining the permit from the Secretary., , Application for development/building permit.- (1) Every person other than a Central or, State Government Department who intends to:-, , (a), , (b), , develop or redevelop any parcel of land by subdividing into plots shall apply in, writing to the Secretary in the form in Appendix A3 and/or, , construct or reconstruct a building or make alteration or addition or extension or, change in occupancy to a building shall apply in writing to the Secretary in the, form in Appendix - A1; and, , such application shall be accompanied by plans and statements in duplicate as per, these rules along with documents to prove the ownership of the land concerned such, as title deed proving the ownership of the applicant, land tax receipt issued by the, village office and the possession certificate issued by the village office and payment, of application fee as specified in Schedule I, along with a copy of certificate of, registration of the Institution, Architect, Building Designer, Engineer, Town Planner, or Supervisor, as the case may be, who has prepared and signed the plans, drawings, and statements. The applicant shall submit the details of Court cases, if any,, pertaining to the land. In case of a Joint Venture development, the agreement, between the land owner and the developer shall also be produced., (2) Applications may also be submitted through e-filing system, as may be prescribed,, if such system is in force in the Local Self Government institution concerned and,, the Secretary may receive, process and issue necessary orders on the application, through e-filing system., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 14
Page 25 :
15, , KERALA PANCHAYAT BUILDING RULES 2019, (3) In the case of any development or redevelopment of land and/or construction or, reconstruction of a building or alteration or addition or extension or change in, occupancy to a building by Central or State Government Department, the officer, authorized shall, before thirty days of commencement of the work, submit to the, Secretary a set of layout plan or plans of the proposed plot subdivisions and/or, a, set of plans of the proposed building, as the case may be, together with all other, details with a certificate duly signed by the Chief Architect or the Engineer- incharge of the works to the effect that the plans are in conformity with the, provisions of these rules in all respects including conformity to any Master Plan /, Detailed Town Planning Scheme / Interim Development Order in force under the, Kerala Town and Country Planning Act, 2016 (9 of 2016), prepared for the area., In such cases approvals from Chief Town Planner or District Town Planner, as the, case may be, and permit from the Secretary as per these rules are not required., , Sl., no., 1, , 2, 3, 4, 5, 6, 7, , (4) In the following cases the Secretary shall obtain, if not produced by the applicant,, after receiving the application for permit / written information from the applicant,, whether it is Central Government, State Government, autonomous bodies, Quasigovernmental agencies, local self-government institutions, Co-operative Societies,, Devaswom boards, private parties etc., a written consent/ concurrence/ NOC from, the officer/ authority concerned before issuing the permit. The applicant may, directly obtain NOC/Permission, if any required, from organizations and submit, along with the application for permit., Location/ Use of the site and or building, , Officer/ authority, , Proposed building is within 10m from Defence, Establishment, or, Proposed high rise buildings within 500m from Defence, Establishment or Telecommunication towers within 200m, from Defence establishment, or, as per notification issued by Defence establishment from, time to time, Proposed buildings within 30m from Railway track, boundary or Telecommunication towers within 100m, from Railway track boundary., Proposed site/buildings in areas declared, identified or, advised by the Kerala Urban Arts Commission as, possessing heritage value., Proposed buildings within any Security Zone, Proposed buildings/places for religious purpose or, worship, Proposed fuel filling stations, Proposed crematoria or burning and burial grounds, including cemetery and vaults, , Officer in charge of, the Defence, establishment, , Railway Authority, concerned, The Kerala Urban Arts, Commission, District Collector, District Collector, District Collector, District Collector, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 15
Page 26 :
16, , KERALA PANCHAYAT BUILDING RULES 2019, 8, , Proposed site/buildings in any area notified by the Kerala Coastal Zone, Government of India as a coastal regulation zone under Management, the Environment Protection Act, 1986 (Central Act 29 of Authority (KCZMA), 1986) and rules made there under., , 9, , Any activity as specified in the schedule to the, Notification No. S.O. 1533(E) dated the 14th September,, 2006 and as amended from time to time, issued by the, Ministry of Environment and Forests, Government of, India, , 10, , As per prevailing statutes of the Kerala State Pollution, Control Board., Proposed traffic terminal stations like mobility hubs, bus, stands or inter-state bus terminals, i. All buildings under Group A1, A2, B,, C,E,F,G1,G2and H occupancy exceeding 1000 sqm, of built-up area or exceeding 15 m of height, ii. All buildings under Group D, I and J occupancy, irrespective of the number of storeys., , 11, 12, , 13, , All buildings under Group A1, A2, B, C, E, F, G1, G2, and H occupancy exceeding 300 sqm and below 1000, sqm of built-up area, as also in the case of buildings not, exceeding 15 m height., , State Level, Environment Impact, Assessment Authority, (SEIAA) / Ministry of, Environment and, Forests, Kerala State Pollution, Control Board, Chief Town Planner, Director, of, Department of, Fire, and Rescue Services or, an officer authorized, by him in this regard, to the effect that the, construction of the, building conforms to, the fire and safety, norms specified in part, 4 Fire and Life Safety, of National Building, Code of India, 2016, and, subsequent, amendments., A self-declaration in, the form in AppendixL from the applicant, along with a certificate, from, the, architect/engineer,, who had prepared the, plan, to the effect that, the construction of the, building conforms to, the fire and safety, norms specified in part, 4 Fire and Life Safety, of National Building, Code of India, 2016, and, subsequent, amendments., Also, a copy of the self, declaration form and, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 16
Page 27 :
17, , KERALA PANCHAYAT BUILDING RULES 2019, certificate, of, the, architect/, engineer, shall be submitted to, the, nearest, Fire, Station., Proposed buildings within 20km vicinity from Airport Airport Authority of, Reference Point (ARP) and/or as per the colour coded India (AAI), zoning map approved for each airport and/or all buildings, having elevation more than 150m from ground level, Proposed single storeyed buildings below the Electrical Chief Electrical, line and if clearance not available as per rule 22 (5) Table Inspector / an Officer, 2 and for installation of transformers, authorized by him in, this regard, Any activity within 300 metre distance from any Archaeological Survey, protected monument/area notified by the Archaeological of India, Survey of India, District Town Planner/, Buildings of various occupancies as mentioned in Table, Chief Town Planner, 11 of these rules, concerned, if required, , 14, 15, 16, 17, 18, , Proposed site/ building forms part of any Town Planning, Scheme for the area, , District Town Planner/, Chief Town Planner, concerned, if required, , Provided that, the required permission/No Objection Certificate of any other, Departments/Agencies as required under law may also be obtained for any land, developments or constructions., Provided that the Secretary shall issue permit for Single family residential buildings, upto 300 m2 of build up area coming under Coastal Regulation Zone, in accordance with, the provisions of the relevant Coastal Regulation Zone notification in force., Provided further that, such officer/authority concerned shall furnish his reply within, fifteen days from the date of receipt of the consultation letter, if such establishment has any, objection to the proposed work. The objection, if any, raised by the officer within the said, fifteen days shall be duly considered by the Secretary before issuing permit. All these are, subjected to amendments of the relevant Acts from time to time., In cases where final remarks are not received within the said fifteen days from the, Officer or Railway Authority as in sub-rule (4), the Secretary may delay final decision in, the application for permit, if any interim reply is received from the Officer/Railway, Authority concerned. Provided that provisions regarding the height of the building as, specified in the National Building Code of India 2016 shall not apply to multiplexes., , Note:, , (i) In the case of all livestock and poultry farms under group G1 or G2 occupancies, and, vaults and burial grounds under Group I occupancy, certificate of approval from the, Director of Department of Fire and Rescue Services is not necessary., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 17
Page 28 :
18, , KERALA PANCHAYAT BUILDING RULES 2019, (ii) Applications for renovation without involving additional built-up area or structural, alterations of existing buildings for religious purpose or places of worship can be, considered by the Secretary after informing the District Collector in Form in, Appendix-I duly filled by the applicant and verified by the Secretary., (5) (1) Any new building under any of the following occupancies as provided under, rule 25 of these rules, having a connected load of 100 kW or greater, or a contract, demand of 120 kVA or greater, or having air-conditioned area of 500 sqm. or, greater, require the compliance of the provisions of Kerala State Energy, Conservation Building Code:Group A2: Special Residential,, Group B: Educational,, Group C: Medical / Hospital, Group D: Assembly,, Group E: Offices/Business, Group F: Mercantile/Commercial and, Group H: Storage, (2) Along with the application for building permit submitted to the Local Self, Government Institution concerned for issuing building permit, the applicant, shall submit the forms mentioned in the Kerala State Energy Conservation, Building Code Rules, notified by Kerala Government., Provided that a copy of the above said documents, with certification from a, certified Energy Auditor (Building) shall be submitted simultaneously to the, State Designated Agency, who shall scrutinize the same and intimate any noncompliance to the applicant and to the Local Self Government Institution, concerned within thirty days of receipt., If any noncompliance has been pointed out by the State Designated, Agency, the Local Self Government Institution shall get a further certificate of, rectification from the applicant through the certified Energy Auditor (Building), before issuing the building completion certificate as per schedule, section 3 of, Kerala State Energy Conservation Building Code (KSECBC), (6) Layout of buildings and/or usage of plots/ concurrence;-, , (1) While issuing approval for plot sub division lay outs or usage of plot and/or, , layout of buildings, the District Town Planner or Chief Town Planner as the, case may be, shall consider the following aspects., (a) Usage of Plot: Usage of plot shall be governed by the provisions of the, Master Plan / Detailed Town Planning Scheme / Interim Development Order, in force under the Kerala Town and Country Planning Act, 2016 (9 of 2016), prevailing in the area. In the absence of such a plan / scheme / order,, approval for usage of the plot is determined in consideration of the, following:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 18
Page 29 :
19, , KERALA PANCHAYAT BUILDING RULES 2019, (i), , The surrounding developments, , (iii), , Physical aspects of the plot, , (ii), , (b), , (iv), , Availability of infrastructure facilities, Impact on the surrounding area, , Layout of Building: Approval for layout of building(s) is determined in, consideration of the following:, (i), , Access to the plot and building, , (iii), , General setting of the building, , (ii), , (iv), (v), , (vi), , Alignment of the internal roads, Parking arrangements and maneuverability, Aspects related to FAR and Coverage, Different uses within building, , (vii) Provisions of the Master Plan / Detailed Town Planning Scheme/, Interim Development Order, if any, in force under the Kerala Town and, Country Planning, Act, 2016 (9 of 2016)., , (c ) Concurrence : Concurrence shall be governed by the provisions of the Master, Plan / Detailed Town Planning Scheme / Interim Development Order in force, under the Kerala Town and Country Planning Act, 2016 (9 of 2016), prevailing in the area considering the following aspects and suggest, conditions with respect to the following., (i), , (ii), , (iii), (iv), , The surrounding developments, , Availability of infrastructure facilities, Physical aspects of the plot, , Impact on the surrounding area, , (2) Application for Layout approval and Usage of plot/Concurrence shall be, , submitted in the form in Appendix-A4 along with, Schedule III, , scrutiny, , fee, , as, , per, , (3) Such approval from District Town Planner or Chief Town Planner, as the case, , may be, may specify conditions with due consideration to various planning, aspects pertaining to the particular development/construction and local, developments and there may also be additional conditions not specified in these, rules;, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 19
Page 30 :
20, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that these conditions so specified shall not in any form be, interpreted to relax the provisions of these rules;, , Provided further that, before the approval of the site and plans and issue, of permit, the Secretary shall ensure that the application, drawings and, specifications conform to the provisions of these rules and other applicable, statutes and the conditions, if any, stipulated by Chief Town Planner or District, Town Planner, as the case may be., , (4) For any deviation without change in occupancy and upto 5% of the total built up, , area in the plan approved by the District Town Planner / Chief Town Planner for, layout of buildings and usage of plot as per these rules, but limited to 500 sqm., without change in occupancy, revised approval from the District Town Planner/, Chief Town Planner is not necessary. However, if there are serious deviations, from such approved plan, fresh approvals shall be obtained from the Chief, Town Planner or District Town Planner as the case may be., , (5) Approval / Rejection /any other communication of layout and/or usage of plot, , shall be intimated to the applicant in writing within one month in the case of, District Town Planner and within two months in the case of Chief Town, Planner., , 6 Plans to be submitted - (1) An application for a development permit shall be accompanied, by atleast 3 copies of site plan, service plan and key map together with details and, specifications as prescribed in these rules., (2) An application for building permit shall be accompanied by atleast 3 copies of, site plan, service plan, key map, building plan, safety plan in case of high rise, buildings, parking plan wherever the building requires parking space as per these, rules, together with details and specifications as prescribed in these rules., , (3) All plans submitted shall include the name, address and signature of the land, owner, applicant and registered Institution/Architect/ Engineer/ Town Planner/, Supervisor. Also, the plans have to be certified by the registered Architect/, Engineer/ Town Planner/ Supervisor as given in Appendix J1., , (4) Site Plan;- (a) The site plan shall be drawn to a scale of not less than 1:400, fully, dimensioned and shall show:, (i) boundaries of the plot intended for the proposed construction and any, contiguous land belonging to the same owner including the revenue details like, survey number with sub division, block, village, taluk, extent of plot etc., (ii) the number of the nearest building and electric post and the position of the, site in relation to the neighboring street and its main access;, (iii) the name of such street, if any; street levels and its width, which shall be the, width in between the plot boundaries on the opposite sides;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 20
Page 31 :
21, , KERALA PANCHAYAT BUILDING RULES 2019, (iv) shall clearly show the setbacks of all existing and proposed buildings within, the plot and also show all existing and proposed buildings above or below the, ground level with their uses, appurtenant structures, proposed finished ground, levels and authorised building numbers of the existing buildings within the, plot issued by the Panchayat;, (v)consolidated statement of the plot area, covered area and floor wise and use, wise built-up area of both existing and proposed buildings including that of, accessory buildings, Floor Space index and Coverage., , (vi) all existing and proposed streets or foot - paths within the plot with its width, to scale:, , (vii) the area and location of any land within the plot that is undevelopable such as, rocky outcrops, steep terrains, marshes, water bodies, puramboke land etc;, , (viii) the area and location of any land within the plot that is not proposed to be, developed or redeveloped and any land that is proposed to be reclaimed;, , (ix) the area and location of any paddy fields and/or other agricultural land that, are proposed to be reclaimed and /or converted for the said development or, re- development;, (x)the position of external toilets, cattle sheds, stables, wells and other, appurtenant structures; and, , (xi) the north direction, predominant wind direction in relation to the site and any, other relevant information of the plot not specifically mentioned, but may be, required by the Secretary., (xii) topographic contours (with contour intervals not greater than 1.5 metre to, show the features of the plot clearly) of the site if required by the Secretary /, District Town Planning Office., (xiii) All existing natural streams/drains within the plot, if any, , (xiv) World Geodetic System (WGS -84) coordinates (latitude and longitude) of, the site and elevation of the top most point of the building with respect to, mean sea level, if the plot falls within the Colour Coded Zone Map (CCZM), prepared by the Airport Authority of India and/or for buildings with elevation, more than 150m as per Aircraft Act, 1994. (Central Act XXII of 1934), Provided that when circumstances are such as to make a smaller plan, necessary or sufficient, the plan may be drawn to a scale of 1: 800 if, acceptable by the Secretary., , (b) In the case of site plan for plot sub division layouts, in addition to items in (a), above, the following details shall also be furnished:FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 21
Page 32 :
22, , KERALA PANCHAYAT BUILDING RULES 2019, (i), , the layout of cul-de-sac, streets or foot-paths within, adjoining or, terminating at the site, existing and/or proposed to be widened or newly, aligned;, , (ii) the proposed plot subdivision, and the area and use of each sub division, thereof;, (iii) the access to each plot subdivision;, , (iv) the layout of any service road or foot path and public parking spaces, proposed or existing, if any;, , (5) Key map:-The site plan shall be accompanied by a key map giving full details of, the location of the site with reference to north direction, all adjacent streets,, junctions, premises and landmarks., (6), , Service Plan:-The service plan shall be drawn to a scale not less than that of the, site plan, and shall show:(i), , (ii), , the proposed plot sub-division, if any, and the uses of such sub- division;, , the layout of existing and proposed water supply, electricity, drainage and, sewerage main lines from or to which connections are proposed to be given, with dimensions and specifications;, , (iii) the layout of existing and proposed water supply, electricity, drainage and, sewerage lines within the plot, with dimensions, specifications and, description of installation;, (iv) any other relevant information not specifically mentioned but may be, required by the Secretary; and, (v), , the north direction and predominant wind direction in relation to the site., , (7) Building Plan:- The plans, elevations and sectional elevations in the building plan, accompanying the application shall be accurately drawn to a scale of not less than, 1: 100,fully dimensioned and shall,-, , (i), , (ii), , (iii), , (iv), , include floor plans of all floors together with consolidated statement on the plot, area, covered area and floor wise and use wise built-up area, including that of, accessory buildings, if any, and such drawings shall clearly indicate the sizes and, spacing of all framing members, size of rooms, levels of each floor, position of, staircases, travel distance between staircases, ramps and lift wells;, show the use or occupancy of all parts of the buildings;, , show the exact location of essential services like water closets, sink and bath;, , include sectional drawings showing the lowest ground level contiguous to the, building, highest ground level contiguous to the building, levels of each floor,, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 22
Page 33 :
23, , KERALA PANCHAYAT BUILDING RULES 2019, , (v), , (vi), , (vii), , abutting road level, the height of rooms, building and parapet, thickness and, spacing of structural members, floor slabs and roof and details of staircase., show all street elevations;, , give dimensions of the projections, if any;, , include a terrace plan indicating the drainage and the slope of the roof;, , (viii) show the direction of north line relative to the plan of the building; and, (ix), , (x), , specify total and floor wise built up area of the building, , specify, in the case of Group G1 or G2 industrial occupancy and Group I, hazardous occupancy, wherever applicable;, (a) power used in H.P., , (b)number of workers, (c)raw materials used, , (d)flow chart indicating the process, , (e)details of waste generated, , (f)details and methods of disposal of waste, , (8) Parking Plan:-Parking plan shall be drawn to a scale not less than that of the site, plan, in cases where parking is to be provided as per these rules, and shall show, clearly parking spaces, width and slope of drive-ways/ ramps and maneuvering, spaces, parking space for differently abled persons, visitors parking, loading and, unloading spaces etc. along with consolidated statement on calculation of parking, requirements, as per these rules., , (9) Safety Plan: -In the case of high rise buildings, every application for approval shall, be accompanied by a safety plan suitable for the proposed construction duly, certified by the Architect / Licensee/ Engineer that it is in accordance with the, Health and Safety Manual published by the Labour Department., (10) In the case of High rise building the suggestions in the guidelines on use of Glass, in buildings-Human safety, 2015 shall be adhered to wherever glass is extensively, used in building., , (11) Plan showing surrounding developments: -In the case of applications which need, approval of usage of plot and/or layout of building(s) from the District Town, Planner/ Chief Town Planner as per these rules and/or as per the provisions of any, Town Planning Schemes, a sketch shall also be provided showing surrounding, developments approximately within 50 metres from the boundary of the plot, indicating:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 23
Page 34 :
24, , KERALA PANCHAYAT BUILDING RULES 2019, (i), (ii), , distance from plot boundary, use and number of storeys of buildings and, details of other developments, if any;, vacant land, agricultural land, water bodies and other features;, , (iii) any other relevant information not specifically mentioned, but may be, required by the Secretary/ District Town Planner/ Chief Town Planner., , (12) The minimum size of the paper on which all plans are drawn shall not be less than, 297 mm X 420 mm or A3., , (13) The plans accompanying the application shall have the colour scheme as specified, in Table 1 and shall be indicated in the legend in the plans., , TABLE 1, COLOUR SCHEME, Sl.No., , Item, , Notational colouring, , 1, , Plot line, , Thick black line, , Street (proposed), , Brown dotted line, , 2, , Street (existing), , 3, , Brown line, , 4, , Permissible building line, , Thick black dotted line, , 6, , Building (proposed to be demolished), , Yellow hatching, , 8, , Drainage sewerage work, , Red dotted line, , 10, , Electric line, , 5, , Building(Existing), , 7, , Building (proposed), , 9, , Water supply works, , (14), , (15), (16), , Black outline, Red outline, , Black dot and dash line, Green line, , All plans, drawings and specifications shall be certified and signed by a registered, Institution or Architect or Engineer or Town Planner or Supervisor or Building, Designer, registered as provided for in these rules, as well as the applicant., , If the plot is owned by more than one person, the application shall be submitted, jointly and signed by all the persons or by legally authorized representatives of, such persons, if any., If the application is for construction or reconstruction of a single building or, block of buildings in more than one adjoining plots owned by different persons,, or to make addition or extension or alteration to such building, the application, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 24
Page 35 :
25, , KERALA PANCHAYAT BUILDING RULES 2019, , (17), , 7., , shall be submitted jointly and signed by all the persons or by legally authorized, representatives of such persons, if any., , The Secretary shall, after considering the application, plans and drawings and, other documents, issue development permit in the form in Appendix B1 or, building permit in the form in Appendix B2, as the case may be., , Certain operational constructions by Government to be exempted from these rulesThe operational constructions of the Central or State Government, whether temporary, or permanent which is necessary for the operation, maintenance, development or, execution of any of the following services shall be exempted from these rules, namely:(a), , Railway;, , (c), , National Waterways;, , (b), (d), (e), (f), , (g), (h), , (i), (j), , (i), , National Highway;, Major Ports;, , Airways and Aerodromes;, , Posts and telegraph, telephones, wireless, broadcasting and other like forms of, communications;, Roads, bridges, street furniture, toll plazas and wayside amenities by the Central, Government, State Government and/or Local Self Government., , Waterway amenities like boat jetties and other waterside facilities for, transportation by the Central Government, State Government and/or Local Self, Government, Regional grid for electricity, , Any other service which the State Government may, if it is of opinion that the, operation, maintenance, development or execution of such service is essential to, the life of the community, by notification, declare to be a service for the purpose, of this clause:, Provided that the following constructions by the services do not come under, the purview of operational constructions, namely: -, , New residential colonies, new residential buildings (other than temporary shelters, which are used for essential operational quarters for limited essential operational, staff and the like) roads and drains in railway colonies, community halls,, hospitals, clubs, all type of educational institutions and offices, shopping, complexes, railway mail service offices, parcel offices; and, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 25
Page 36 :
26, , KERALA PANCHAYAT BUILDING RULES 2019, (ii), , Post offices, other type of office of Posts and Telegraphs Department, residential, colonies., , 8. Permit not necessary for certain works - Notwithstanding anything contained in these, rules, no building permit shall be necessary for executing the following works which, do not otherwise violate any provisions regarding general building requirements,, structural stability and fire safety requirements of these rules, namely:(i), , (ii), , Providing or removing of windows or doors or ventilators;, Providing inter-communication doors;, , (iii) Providing or removing of partitions without any structural alteration;, (iv) Gardening excluding any permanent structures;, (v), , White or color washing;, , (vi) Painting;, , (vii) Petty repairs to the building and pitched roof;, (viii) Plastering and patch work;, , (ix) Interior decoration without any structural alterations; and, (x), , Changing of the location of the building or construction within the plot;, , (xi) Compound wall not abutting a public street;, , (xii) Huts, except huts adjacent to roads mentioned in section 235P of the Kerala, Panchayat Raj Act, 1994;, , (xiii) Single family residential buildings in Category –II Village Panchayats, under Group A1-Residential occupancy with total built-up area on all floors, upto 100 sq.metres (including existing and proposed within the plot) and the, number of storeys limited to two., , 9., , Provided that the changing of the location under item (x) shall be, incorporated in the completion plan., Provided further that, except in cases as specified in rule 5(6)(3), if the, change in location under item (x) above, is in deviation from any approvals,, concurrences etc. obtained from any of the agencies/authorities concerned, other, than that obtained from the Panchayat, as per these rules or bye laws made under the, Act and any other law, such approval, concurrences etc. shall be obtained afresh., , Approval of site and plans and issue of permit - (1) On receipt of the application, with the supporting documents attached thereto, the Secretary or the officer duly, authorised by the Secretary shall issue an acknowledgement to the applicant on the, same day and inform the applicant whether any No Objection certificate required from, other authorities is /are not attached with the application., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 26
Page 37 :
27, , KERALA PANCHAYAT BUILDING RULES 2019, (2) The Secretary shall, after inspection of the site and verification of the site plan, and documents, if convinced of the bonafides of the ownership of the site, and, that the site plan, drawings and specifications conform to the site and the, provisions of these rules or bylaws made under the Act and any other law,, approve the site and site plan and record a certificate to that effect in the site plan, as given in Appendix J2. The online inspection report shall be submitted within, 48 hours of receipt of application for building permit., (3) The Secretary shall, after approving the site and site plan, verify whether the, building plan, elevation and sectional elevation of the building and specifications, of the work conform to the site and site plan, and is in accordance with these rules, and bye laws made under the Act or any other law, approve the plan and issue, permit to execute the work., , (4) Approval of site and plans shall be intimated to the applicant in writing and the, permit as in Appendix B2 shall be issued on remittance of the permit fee at the, rates specified in Schedule II and submission of revised or modified plans, if, approved with modifications or conditions., (5), , If after inspection of the site and verification of the plans and documents,, Secretary decides to refuse approval, the same shall be communicated in writing, specifying the reasons., , (6) Secretary shall, if modification to any plan, drawing or specification is required or, any further document or plan or information is required or fresh plan is required, under these rules for taking a decision, intimate the same to the applicant in, writing within ten days from the date of receipt of such application or plan or, document or information., (7) Approval of site and plan shall take effect from the date of submission of the, application and rules at the time of issue of permit shall be applicable., , 10. Approval of site and plans and issue of permit where excavations to a depth of more, than 1.5 metres is involved - (1) In the case of constructions/land developments which, involve any earthwork excavation to a depth of more than 1.5 metres, if the depth of, cutting is more than the horizontal distance of such cutting from the plot boundary, the, following provisions shall apply:, Provided that, such provisions are not necessary in cases where such excavation, is carried out for construction of structures such as wells, septic tank, recharge pits,, drainage works, compound walls and the like., , (2) The application for development and/or building permit shall be submitted by the, applicant as per the provisions of these rules, along with a certificate of the, Institution, Architect, Building Designer, Engineer, Town Planner, Supervisor as, the case may be, who has prepared and signed the plans, drawings, statements etc., as to whether permit as envisaged under rule 10 is required., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 27
Page 38 :
28, , KERALA PANCHAYAT BUILDING RULES 2019, (3) The application for permit shall also include sufficient copies of: (i), , (ii), (iii), (iv), , dimensioned plan and sectional drawing showing the abutting road level,, the levels and depths of cutting at all places in respect of excavations for, building construction and land development works;, drawings, specifications and details of temporary and permanent protective, measures proposed;, , drawings, specifications and details of slabs, beams, columns, retaining, walls etc. proposed at the ground floor level and below; and, , details of piles if any, including their drawings, specifications, erection, methods and the like., , (4) The Secretary shall issue permit as laid down in these rules:, , Provided that, if any changes or deviations are to be made, it shall satisfy the, provisions of these rules and the same shall be intimated to the Secretary with, revised drawings, specifications and details as the case may be., , (5) Any written complaint received after the date of issue of the permit from owners or, occupants in the adjoining properties on the actual or possible damages to their life, and property shall be acted upon by the Secretary as per the provisions in this rule:, Provided that the work will not be stopped except under exceptional, circumstances such as violation of approved plans and risk of danger to life and, property., , (6) Once the earthworks and/or constructions upto the ground level are completed as, per the approved plans, the applicant may in writing intimate the same to the, Secretary and request for concurrence for carrying out rest of the works., , (7) The Secretary shall, if convinced that the works are carried out satisfactorily as per, the permit(s) and provisions of this rule and no written complaint is received as in, subrule (5), issue concurrence as in Appendix C for carrying out the remaining, works above the ground level as per approved plans within 7 days after intimating, the completion of works upto ground level:, Provided that, if no objection is raised by the Secretary within the said, period to the construction carried out, the applicant may continue with the work, above ground level as if concurrence has been given., , (8) If any complaint is received as in sub rule (5), the Secretary shall:, (i), , (ii), , refer the matter within 5 days to the Technical Expert Committee, constituted as per subrule (12) and convene a meeting of the Committee;, , intimate the nature of complaints to the applicant and call for details and, explanation if so desired by the Committee;, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 28
Page 39 :
29, , KERALA PANCHAYAT BUILDING RULES 2019, (iii), , (iv), , arrange for site inspections, hearing of the applicants and/or petitioners,, verification of records and arrange for tests if so required by the Committee;, and, take up further action as per the recommendations of the Committee., , (9) The applicant and/or the petitioner shall attend the hearing and shall also produce, any details called for within the time specified, if so required by the Committee or, the Secretary on its behalf, , (10) The Committee shall evaluate the damages and fix the compensation and/or, suggest further protective measures, if any, to be taken by the applicant to solve, the issues raised by the petitioner. The amount of compensation shall include the, actual cost of restoration as decided by the Committee and an additional 30% as, solatium:, Provided that the process of the Committee shall be completed within a total, duration of 3 weeks., , (11) Concurrence shall be issued by the Secretary, after ensuring that the protective, measures are carried out to the satisfaction of the Committee and the compensation, is paid by the applicant as per the decision of the Committee. The actual expenses, of the Committee as intimated by the Secretary shall be paid by the applicant., , 11., , (12) For the purpose of this rule, Government may, constitute Panchayat level, Technical Expert Committee(s) comprising of Secretary (convener), an officer not, below the rank of an Assistant Engineer of the Engineering wing of Local Self, Government Department having jurisdiction over the area and two experts; one, each in Structural Engineering and Geotechnical Engineering (to be nominated by, Government) to assess the damage, suggest protective measures and fix the, compensation. The process of the Committee shall be completed in 3 weeks., , Grounds on which approval of site or permission to construct or reconstruct building, may be rejected - Any application made under these rules shall be rejected by the, Secretary if the application is not in compliance with these rules or any other relevant, statutes in force. The Secretary shall specify the grounds for rejection in the order, rejecting the application., , The grounds on which approval of site for construction or reconstruction of a, building or permission to construct or reconstruct a building shall be refused are the, following; namely:(i), , that the work or use of the site for the work or any particulars comprised in, the site plan, building plan etc., elevations, sectional elevation, or, specifications would contravene provisions of any law or order, rule,, declaration or bye law made under such law;, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 29
Page 40 :
30, , KERALA PANCHAYAT BUILDING RULES 2019, (ii), , (iii), , (iv), , (v), , (vi), , that the application for such permission does not contain the particulars or is, not prepared in the manner required by these rules or bye law made under, the Act;, , that any of the documents required to be signed by a registered Institution,, Architect, Building Designer, Engineer, Town Planner or Supervisor and/or, the owner /applicant as required under the Act or these rules or bye laws, made under the Act has not been signed by such Institution, Architect,, Building Designer, Engineer, Town Planner or Supervisor and/or the, owner/applicant;, , that any information or document or certificate required by the Secretary, under these rules or bye laws made under the Act has not been duly, furnished;, , that the owner of the land has not laid down and made street or streets or, road or roads giving access to the site or sites connecting with an existing, public or private street while utilizing, selling or leasing out or otherwise, disposing of the land or any portion or portions of the same site for, construction of building:, Provided that if the site abuts on any existing public or private street no, such street or road shall be laid down or made;, , that the proposed building would be an encroachment upon a land, belonging to the Government or the Panchayat; and, , (vii) that the land is under acquisition proceedings., , 12. Period within which approval or disapproval shall be intimated - The Secretary shall,, within thirty days from the date of receipt of the application for approval of site plan,, or any information or further information required under these rules or bye laws under, the Act, by written order either approve or refuse to approve the site plan on any of the, grounds mentioned in rule 11 and intimate the same to the applicant., , 13. Period within which Secretary is to grant or refuse permission to execute work- The, Secretary shall within thirty days from the date of receipt of an application for, permission to execute any work or any information or document or further information, or further document required under these rules or bye laws made under the Act, by, written order either grant or refuse to grant such permission on any of the grounds, mentioned in rule 11 and intimate the same to the applicant:, Provided that the said thirty days shall not begin to run until the site has been, approved under rule 12., 14. Reference to Village Panchayat where the Secretary delays to grant or refuse or, approve permit - (1) The Village Panchayat shall, if the Secretary, neither approves, nor disapproves a building site, neither gives nor refuses permission to execute any, work within thirty days from the date of receipt of the application, on the written, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 30
Page 41 :
31, , KERALA PANCHAYAT BUILDING RULES 2019, request of the applicant, be bound to determine whether such approval or permission, should be given or not., , (2) Where the Village Panchayat does not, within thirty days from the date of receipt of, such written request, determine whether such approval or permission should be, given or not, such approval or permission shall be deemed to have been given, and, the applicant may proceed to execute work, but not so as to contravene any, provision of the Act or these rules or bye-laws made there under:, Provided that such execution of work shall be considered as duly permitted, and not one for regularization and permit shall be issued as per rules even if the, work has been commenced, being carried on or completed if it otherwise complies, with rule provisions., , (3) On the expiry of sixty clear days from the date of valid applications the applicant, shall submit a letter stating that he is commencing the work of the, building/structure/telecommunication/mobile tower applied for as provided in the, original applications as per Rules, specifying the date of commencement., All Secretaries of Local Self Government Institutions shall acknowledge the, receipt of the letter stated in the above paragraph with stamp and date on the same, day on the duplicate copy of the letter. This shall be a deemed permission along, with the acknowledgment of original application submitted., , 15. Extension and renewal of period of permits - (1) A development permit or a building, permit issued under these rules shall be valid for five years from the date of issue., , (2) The Secretary shall, on application submitted within the valid period of the permit,, grant extension once, for further period of five years:, , Provided that, in case the permit needs to be extended beyond the period of, tenyears, the applicant shall submit an application in writing to the Committee, constituted under Chapter IXof these Rules and the committee may, after having, satisfied with the genuineness of the application, recommend for extension of period, of the permit once, with or without condition(s) as it deems fit., , (3) The fee for extension of period of permits shall be ten percent of the building permit, fee excluding the fee for additional Floor Space Index, in force at the time of, granting extension:, , Provided that, in case the period of permit is extended beyond a period of ten, years from the date of issue of original permit, the fee for extension of period of, permit shall be twice that of the permit fee excluding the fee for additional Floor, Space Index, in force at the time of granting extension., (4) The Secretary may, if he deems fit, grant renewal for a period of five years on, application submitted after the expiry of the permit, subject to the condition that the, total period of validity of permit from the date of issue of original permit shall not, exceed ten years:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 31
Page 42 :
32, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that, in case the permit needs to be renewed beyond the period of, ten years, the applicant shall submit an application in writing to the Committee, constituted under Chapter IX of these Rules, within three years from the date of, expiry of the permit, and the Committee may, after having satisfied with the, genuineness of the application, recommend for renewal of the permit once, with or, without condition(s) as it deems fit., , (5) The fee for renewal of period of permit shall be fifty percent of the development, permit fee, in force at the time of renewal:, , Provided that, in case the period of permit is renewed beyond a period of ten, years from the date of issue of original permit, the fee for renewal of period of, permit shall be twice that of the permit fee, in force at the time of granting renewal., , (6) The application for extension or renewal of a development permit or a building, permit shall be submitted in white paper, either typed or written in ink, specifying, the name and address of the applicant, the number and date of issue of the permit,, the stage of development or construction, if already commenced, together with, application fee as provided in Schedule I., (7) The application shall be affixed with necessary court fee stamp and shall contain, the original of the permit and approved plan sought to be extended or renewed., (8) The development work or construction work shall be commenced and completed, within the valid period of the permit., , Note: - Non-commencement of any work within the period specified, if any, in a, permit issued before the commencement of these rules shall not be considered as a, ban for extension or renewal of permit., , (9) A development permit or a building permit issued under the Kerala Panchayat, Building Rules, 2011 including that under the orders of Government granting, exemption from rule provisions, shall be extended or renewed, on proper, application, on like terms and for like periods as a permit issued under these rules., (10) In case the period of validity stipulated in permit issued before the commencement, of these rules is different from that stipulated in subrule (1), then the extension or, renewal of the permit shall be granted in such a way that the total valid period of, the permit shall not exceed ten years., , (11) The application for extension or renewal of a development permit or a building, permit shall be signed and submitted by the owner of the permit or his legal heir to, whom the site devolves or legally authorized representative:, Provided that if the plot or a part of the plot concerned has been transferred,, the application for extension or renewal of permit shall not be accepted and acted, upon until provisions of rule 19 has been fully complied with., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 32
Page 43 :
33, , KERALA PANCHAYAT BUILDING RULES 2019, 16. Suspension and Revocation of permit- The Secretary shall suspend or revoke any, permit issued under these rules if it is satisfied that the applicant has violated any, provisions of the Act or rules or any conditions stipulated in the permit or that the, construction is carried out in deviation of the approved plan or Town Planning scheme, or that the permit was happened to be issued on misrepresentation of fact or law or that, the construction, if carried on, will be a threat to life or property:, Provided that before revoking permit, the owner of the permit shall be given an, opportunity to be heard and the same shall be duly considered by the Secretary., Provided further that if the permit issued under these rules is revoked before, the commencement of the building construction, then the additional fee for FAR, remitted by the applicant ,if any, shall be refunded to the applicant on request and the, permit issued shall be canceled henceforth ., , 17. Duties and responsibilities of the owner or developer - (1)The granting of permit or, the approval of the drawings and specifications or inspections made by the Secretary, during the erection of the building or structure or digging of well shall not in any way, relieve the owner of such building of the responsibility for carrying out the work in, accordance with the requirement of these rules., (2) Every owner/developer shall obtain relevant NOC/clearances required for the, construction of building/ development of plot as per the applicable Acts, rules, law, and amendments in force., , (3) Every owner or developer shall be responsible for the correctness of the, measurements of plot shown in the drawings submitted and it shall not include any, encroachment of other land., , (4) Every owner or developer shall submit details of the Court cases (Courts,, Tribunal, Ombudsman etc.) if any pertaining to or of reference to the plot or, constructions therein., (5) Every owner or developer shall, -, , (a) permit the Secretary or any person authorized by the Secretary or by the, Government for this purpose to enter the plot or building or premises at any, time between 7 a.m. and 6 p.m. normally or at any other time as may be, deemed necessary for the purpose of enforcing the rules, (b) submit a proof of ownership of the plot;, , (c) obtain from the Secretary, sanction for any other allied matter connected with, the development or redevelopment of land or construction or, reconstruction or addition or alteration of building or change of occupancy, of any building or part thereof., (d) give notice to the Secretary of the intention to start work in form Appendix D;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 33
Page 44 :
34, , KERALA PANCHAYAT BUILDING RULES 2019, (e) give written notice to the Secretary regarding completion /partial completion, of work(s) in the form in Appendix E1 or Appendix E2, as the case may be;, and, , (f) obtain a development certificate from the Secretary prior to any sale or, transaction of the plots subdivided as per these rules or building construction, in such subdivided plots, as given in Appendix F1 or obtain an occupancy, certificate from the Secretary prior to any occupancy of the building or part, thereof, after construction or reconstruction or addition or alteration of the, building or part thereof, or change of occupancy of any building or part, thereof as given in Appendix F2., , (6) Every owner or developer shall, as soon as any development or redevelopment of, land or construction or reconstruction or addition or alteration of building is, completed, remove all rubbish, refuse or debris of any description from the plot or, plots on which such operation have been carried out or from any adjoining land, which may have been used for depositing of materials and debris., (7) Every owner or developer shall keep in safe custody the permit, approved plans, and drawings and specifications and results of tests, if any on any material used, for construction and shall keep a copy each of the same at the work site and, produce before the Secretary or any officer authorized for inspection on demand., , (8) Every owner or developer shall display the permit number in the site in a visible, place in a visible manner., (9) Every owner or developer shall take adequate safety precautions at all stages of, construction or reconstruction or addition or alteration or repair or demolition or, removal of the various parts of the building for safeguarding the life of workers, and public against hazards consequent on any aspects of the work., (10) Every owner or developer shall ensure that all protective works carried out to, safeguard the adjoining properties, during construction are sufficient and in good, order to ensure safety., (11) In the case of driven piles vibration is set up which may cause damage to, adjoining structures or service lines depending on the nature of soil condition and, the construction standard of such structures and service lines. Possible extent of all, such damages shall be ascertained in advance, and operation and mode of driving, shall be planned with appropriate measures to ensure safety. If, in the vicinity of a, site where bored or driven piling works are to be carried out, there are old, structures which are likely to be damaged, tell-tales shall be fixed on such, structures to watch their behavior and timely precautions shall be taken against, any undesirable effect., (12) If the owner engages any developer(s) at any time for the construction,, reconstruction, repairs, additions or alterations of buildings or development or, redevelopment of land, the same shall be intimated to the Secretary within a week, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 34
Page 45 :
35, , KERALA PANCHAYAT BUILDING RULES 2019, from the date of agreement ( executed between the owner and the developer), along with a copy of such agreement by which the owner authorizes the developer, to undertake construction, reconstruction, repairs, additions or alterations of, building(s) or development or redevelopment of land in that plot, on behalf of the, owner.The clause describing the financial terms between the owner and developer, need not be disclosed., , (13) Every owner and developer shall include the following details as part of all, advertisements through website pertaining to the building and/or land, development:, (a), , name and address of the owner and developer;, , (c), , number and date of the development permit and/or building permit;, , (e), , date till which the building permit is valid;, , (b), number and date of layout approval and/or approval of usage of plot, and layout of building wherever applicable;, (d), (f), , (g), , name of the Local Self Government Institution issuing the permits;, number of floors permitted;, , conditions if any stipulated in the permits;, , (h), following details shall be furnished as against the respective, provisions of the rules;, (i) coverage and F.S.I. of the construction;, , (ii) area of recreational space inside and outside the building in the case, of apartments / flats under Group A1 occupancy;, (iii) number of parking spaces and loading and unloading spaces and, area earmarked for such spaces;, (iv) minimum width of access to the site and building;, , (i) any other occupancy other than Group A1 – Residential in the case of, apartments/flats, with details of floor area of such occupancy;, , (14) In the case of advertisements pertaining to building construction or land, developments through visual – print media and hoardings, the owner or, developer shall include the details mentioned in item (a) to (f) in sub-rule (13), and the address of the website carrying the details under sub-rule (13)., (15) The Secretary may also publish the details of the permits issued in the website, of the Panchayat as required under Section 271B (3) of the Kerala Panchayat, Raj Act, 1994, (13 of 1994)., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 35
Page 46 :
36, , KERALA PANCHAYAT BUILDING RULES 2019, (16) If any such advertisements are made in contravention to sub-rules (13), (14) and, (15) of this rule, the Secretary or the Government may interfere in the matter., , (17) Every owner or developer shall be responsible for the loss or injury caused to, any person or property due to the lapse on his part to provide safety precautions, or protective measures or safeguards., , (18) Sustainable Waste Management: - Every owner shall adhere to the measures to, support Sustainable Waste Management adopted by the Panchayat like waste, collection from house to house, segregation at household level, providing, separate wet and dry bins at the ground level, decentralized waste recycling /, treatment / reuse etc., (19) The owner of ECBC compliant building shall have full obligation and, responsibility of carrying out the work on the commissioning of the said, building in accordance with the requirements of Kerala State Energy, Conservation Building Code (KSECBC). . Every owner shall select the Certified, Energy Auditor (Building) registered with the Bureau of Energy Efficiency, (BEE) for the building compliance check to be submitted to the State, Designated Agency /Local Self Government Institution concerned, in whose, jurisdiction the Kerala State Energy Conservation Building Code (KSECBC), compliant building is proposed to be erected, to help him to develop the building, design, installation of materials and equipments to meet with the requirements, of Kerala Energy Conservation (Building Code)Rules 2017., The owner also shall;-, , (a) engage Empanelled Energy Auditors (Building) in development of building, design, installation of energy conservation measures and equipment to meet, with the requirements of Kerala Energy Conservation (Building Code)Rules, 2017 and ensure following, namely: (i) finalize the compliance approach relevant for his building project based, on the complexity of the building, budget and time constraints;, (ii) finalize the energy conservation measures as per the Kerala State Energy, Conservation Building Code as amended from time to time having, regard to the location of the proposed building;, (iii) to integrate the energy conservation measures in the building design in, accordance with the provisions of Kerala Energy Conservation (Building, Code)Rules 2017;, (iv) that drawings, specifications and compliance forms are prepared and, energy conservation measures are reflected in the building design, documents and submitted to the authority having jurisdiction in, compliance with the requirements of the rules accompanied by a, certificate specifying the energy performance index ratio of the building, by the Empanelled Energy Auditors (Building) that the documents are as, per the requirement of Kerala Energy Conservation (Building, Code)Rules 2017;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 36
Page 47 :
37, , KERALA PANCHAYAT BUILDING RULES 2019, (v) notice is given within the validity of sanction to the authority having, jurisdiction of his intention to start the construction work at the building, site;, (vi) commence the work within the period specified by the authority having, jurisdiction from the date of such notice or seek extension of time for, starting the construction work, wherever necessary;, (vii) ensure that the designed energy conservation measures are deployed in, the construction of the building and installation of its components and, systems., (b) permit the Empanelled Energy Auditors (Building) to enter the building or, premises at any reasonable time for the purpose of inspection to ensure, compliance of building works with rules and regulations under the Act;, (c) give written notice to the authority having jurisdiction intimating the, completion of the construction work along with a certificate from the, Empanelled Energy Auditors (Building) to the effect that(i) the construction of the building has been done in accordance with the, sanction of the building permit;, (ii) all the energy conservation measures have been installed and inspected,, and they meet the requirements of the Code and Kerala Energy, Conservation (Building Code)Rules 2017;, (iii) the building design meet with the provisions of the Code and Kerala, Energy Conservation (Building Code)Rules 2017;, (d) give written notice to the authority having jurisdiction as well as to the State, designated agency in case of termination of the services of Empanelled, Energy Auditors (Building) and appointment of other Empanelled Energy, Auditors (Building) in its place;, (e) obtain an occupancy permit from the authority having jurisdiction prior to, any occupancy of the building or part thereof after completion of the, building;, (f) report the practical difficulties to the Empanelled Energy Auditors, (Building), if any, in carrying out the provisions of Kerala Energy, Conservation (Building Code)Rules 2017, who shall take necessary action, in consultation with State designated agency and State Energy Conservation, Building Code Implementation Committee;, (g) on the receipt of the notice, if any, from the authority having jurisdiction, he, shall discontinue such usage within reasonable time as specified in such, notice and in no case he shall disregard the provisions of Kerala Energy, Conservation (Building Code)Rules 2017;, (h) where he proposes to alter the installation of any system or material or, equipment on account of improving the energy efficiency of the building, contrary to the system, material or equipment as indicated in the sanction, plan he shall use or install such system or material or equipment after, obtaining the necessary approval of the Empanelled Energy Auditors, (Building):, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 37
Page 48 :
38, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that it does not violate the spirit and intent of the provisions, of Kerala Energy Conservation (Building Code)Rules 2017;, Provided further that such change shall not compromise with the, building requirements namely, structural stability, safety, health or, environmental provisions of Central laws and State laws applicable to the, buildings covered under Kerala Energy Conservation (Building Code), Rules 2017., , 18. Responsibilities and functions of registered Architects, etc - (1) Plans and drawings, shall be prepared strictly in conformity with the provisions contained in the Act and the, Rules, any direction issued by Government or Panchayat, all applicable statutes and a, certificate to that effect shall be recorded and signed in the plans and drawings., (2) Every owner/developer shall obtain relevant NOC/clearances required for the, construction of building/ development of plot as per the applicable Acts, rules,, law and amendments in force., (3) A certificate of verification of site shall be recorded and signed in the site plan., , (4) Plans and drawings shall only be prepared after inspecting the site and convinced, of the boundaries., , (5) Every building has to be designed incorporating all safety precautions and, protective measures and shall be responsible for the loss or injury caused to any, person or property due to the lapse on his part., (6) The person issuing the certificate or affixing signature on the plan, drawing or, specification shall be responsible for the correctness or truthfulness of the, recording in the certificate or plan, drawings or specifications., , (7) The person issuing completion certificate shall ensure that building construction/, land development is carried out in accordance with the approved plan., (8) Function shall be restricted to the category on which registration is obtained., , (9) Any person violating the rules under this chapter shall be liable to action under, sub-rules (10), (11) and (15)., , (10) The Registering Authority may, on complaint by any person or on report from any, Panchayat or suomotu take action against any person registered, for violating any, of the provisions under these rules. The Secretary shall sent a monthly report of, all violations along with details to the registering authority., , (11) The Registering Authority may, if convinced on enquiry that the person against, whom action has been taken under sub-rule (9) has violated any rule, provision or, issued false certificate or recorded false information, suspend the registration for a, period not exceeding one year or cancel the registration or disqualify him for, future registration and the matter may be published in the website of the, Government/Department:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 38
Page 49 :
39, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that before finalising the decision, the person concerned shall, be given sufficient opportunity to explain and the explanation, if any, submitted, shall be duly considered by the Registering Authority., , (12) Any person aggrieved by the decision of the Registering Authority under sub-rule, (10) may appeal to Government within 30 days from the date of receipt of the, decision., , (13) The appeal shall be submitted in white paper stating the reasons thereof, typed or, written in ink, affixed with necessary court fee stamp, along with copy of the, order of Registering Authority., , (14) Government shall dispose of the appeal within 60 days, after hearing the appellant, in person or by authorised representative., , (15) The registered Institution/ Architect / Engineer/ Town Planner etc. including the, Developer if any, to whom License has been accorded by the registering authority, concerned, are wholly and severally responsible for ensuring that the building is, constructed as per the approved Building Plan. If any breach or laxity is found, against them in this regard, action shall be taken against the licensed technical, personnel concerned for black-listing and this would entail not only debarring, them from practice in the entire State for 5 years, but also cancellation of their, license besides being prosecuted under the relevant laws / code of conduct by the, registering authority., (16) In case of any firm applying for permit will be equally responsible as that of, registered Institution/ Architect / Engineer/ Town Planner etc., , 19. Transfer of plots to be intimated - (1) Every person holding development permit or, building permit shall, unless the work has been executed in full and development or, occupancy certificate obtained, inform the Secretary, every transfer of the whole or part, of any property involved in the permit together with the name and address of the, transferee and his intention to transfer or otherwise of the permit., (2) Every person, in whose favour any property is transferred along with a, development or building permit by the transferor, shall before commencing or, continuing the work obtain permit of the Secretary in writing., (3), , The request for permission to commence or continue work shall be submitted in, white paper along with documents, together with document regarding the, ownership and possession certificate and fee of Rs100., , (4) The Secretary shall, if convinced that the transfer will not in any way badly affect, the development or construction, issue permission in writing, transferring the, permit and allowing the commencement or continuation of work, within 15 days, from the date of receipt of the request., , (5) Permit issued becomes invalid if part of the plot included in the approved plan is, transferred / sold to any other person., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 39
Page 50 :
40, , KERALA PANCHAYAT BUILDING RULES 2019, 20., , Completion certificate, development certificate and occupancy certificate - (1), Every owner shall, on completion of development or redevelopment of land or, construction or reconstruction or addition or alteration of building, as per the permit, issued to him, submit a completion certificate certified and signed by him to the, Secretary in the form in Appendix E1 together with sufficient copies of plans and, drawings of completed building., Provided that in the case of buildings, other than residential buildings upto two, floors with total built-up area not exceeding 150 sq. metres, the completion certificate, shall be certified and signed by the owner and registered Institution or Architect or, Building Designer or Engineer or Supervisor also as in Appendix E3 together with, sufficient copies of plans and drawings of completed building., , (2) The Secretary shall, on receipt of the completion certificate and on being satisfied, that the development or redevelopment of land has been effected in conformity, with the permit given, issue a development certificate in the form in Appendix F1, along with a copy of the plans duly signed by the Secretary, not later than 15 days, from the date of receipt of the completion certificate:, Provided that if no such development certificate is received within the said, fifteen days, the owner may proceed as if such a development certificate has been, duly issued to him., , On the expiry of fifteen clear days from the date of valid application for, development certificate, the applicant shall submit a letter stating that he is liable, to get development certificate and now it is deemed to have issued by the, authority., All Secretaries of Local Self Government Institutions shall acknowledge the, receipt of the letter stated in the above paragraph with stamp and date on the same, day on the duplicate copy of the letter. This shall be a deemed development, certificate., , (3) The Secretary shall, on receipt of the completion certificate and on being satisfied, that the construction or reconstruction or addition or alteration has been carried, out in conformity with the permit given, issue occupancy certificate in the form in, Appendix F2 not later than fifteen days from the date of receipt of the completion, certificate:, Provided that, in case there is deficiency as per provisions of these Rules, in, minimum width of mandatory open space/yard after completion of the, construction, other than the distance stipulated as per section 220(b) of the Kerala, Panchayat Raj Act, 1994 (13 of 1994) and sub-rule 5 of rule 81 of these rules, the, Secretary may allow a tolerance up to 5% of the minimum mandatory open, space/yard to be provided as per these rules or twenty five centimeters, whichever, is less, for the building constructed:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 40
Page 51 :
41, , KERALA PANCHAYAT BUILDING RULES 2019, Provided further that if no such occupancy certificate is issued within the, said fifteen days, the owner may proceed as if such occupancy certificate has, been duly issued to him., , On the expiry of fifteen clear days from the date of valid application for, occupancy certificate, the applicant shall submit a letter stating that he is liable to, get occupancy certificate and now it is deemed to have issued by the authority., , All Secretaries of Local Self Government Institutions shall acknowledge the, receipt of the letter stated in the above paragraph with stamp and date on the same, day on the duplicate copy of the letter. This shall be a deemed occupancy, certificate., , (4) The owner of a building may, if he intends to occupy the building before its, completion, apply to the Secretary for that purpose together with partial, completion certificate by the owner and registered Institution / Architect /, Building designer /Engineer / Supervisor in Appendix E2 and E4 respectively,, and sufficient copies of plans and drawings of partially completed building, , 21., , (5) Secretary shall ensure the compliance of the provisions of these rules in respect of, the partially completed building and on being satisfied that such occupancy will, not endanger life, issue occupancy certificate in respect of such partially, completed building., Post Occupancy Audit - (1) The Secretary shall carry out Post Occupancy Audit, except for residential buildings upto two storey, commercial buildings upto 50 square, meters, religious buildings and buildings under group G1, G2 and I occupancies,, within two years of issue of Occupancy Certificate., , (2) Post Occupancy Audit can be done at any time after two years after issue of, Occupancy Certificate., CHAPTER III, GENERAL PROVISIONS REGARDING SITE AND BUILDING REQUIREMENTS, 22., , General requirement regarding plot- (1) No land development or redevelopment, shall be made or no building shall be constructed on any plot on any part of which, there is deposited refuse, excreta or other offensive matter which in the opinion of the, Secretary is considered objectionable, until such refuse, excreta or other offensive, matter has been removed there from and the plot has been prepared or left in a manner, suitable for land development or building purpose for the satisfaction of the Secretary., , (2) No land development or redevelopment shall be made or no building shall be, constructed on a plot, which comprises or includes a pit, quarry or other similar, excavation or any part thereof unless such plot has been prepared or left in a, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 41
Page 52 :
42, , KERALA PANCHAYAT BUILDING RULES 2019, manner or condition suitable for land development or redevelopment or building, purposes to the satisfaction of the Secretary., , (3) No land development or redevelopment shall be made or no building shall be, constructed on a plot notified by grama Panchayat which is liable to be flooded or, on a slope forming an angle of more than 45 degrees with horizontal or on soil, unsuitable for percolation or on area shown as floodable area in any Master, Plan / Detailed Town Planning Scheme / Interim Development Order in force, under the Kerala Town and Country Planning Act, 2016 (9 of 2016)or in sandy, beds, unless it is proved by the owner to the satisfaction of the Secretary that, construction of such a building will not be dangerous or injurious to health and the, site will not be subjected to flooding or erosion or cause undue expenditure of, public funds for providing sewers, sanitation, water supply or other public, services., (4) No construction shall be made to obstruct the natural drains and streams in a plot., Failure to comply with this instruction will invite penalization under Section 51 of, the Disaster Management Act, 2005 (Central Act 53 of 2005)., , (5) No building or part of a building shall be constructed or reconstructed or no, addition or alteration shall be made to any existing building in the intervening, spaces between the building and any overhead electric supply line as described in, the Table 2 below and as specified in the Indian Electricity Rules as amended, from time to time., , Provided that single storied buildings shall be allowed even if the above, mentioned clearance is not available,if the applicant produces a no objection, certificate from the Chief Electrical Inspector or an officer authorized by him,, before issue of permit., TABLE 2, , CLEARANCE FROM OVERHEAD ELECTRIC LINES, Sl.No., (1), 1, , Type of Electric Supply Line, (2), Low and medium voltage lines, , 2, , High voltage lines, including 33,000 volts, , upto, , 3, , Extra high voltage lines above, 33,000 volts, , and, , (3), 2.5, , Minimum, Horizontal clearance, in metres., (4), 1.2, , 3.7, , 2, , 3.7, , 2, , Minimum Vertical, , clearance in metres, , plus 0.3m for every plus 0.3m for every, additional, 33,000 additional, 33,000, volts or part thereof, volts or part thereof, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 42
Page 53 :
43, , KERALA PANCHAYAT BUILDING RULES 2019, 23., , Prohibition for constructions abutting public roads- (1) No, person, shall, construct any building other than compound wall or fence or outdoor display structure, within 3 meters, from any plot boundary abutting national highways, state highways,, district roads, other roads notified by Panchayat, other un-notified roads with width 6m, and above:, , Provided that ramps or bridges or steps or similar structures, all open to sky, with, or without parapets or railings shall be permitted as access from the street to the building, only in such cases where the level difference between the street and the plot does not, permit natural access to the building.Cornice roof or weather shade, not exceeding 75, cms shall be permitted to project from the building into such 3 metres. In no case, access, to more than one floor can be provided within this 3 metres., Provided further that the underneath of such flight of steps or ramp shall not be enclosed, or made usable, however pillars may be permitted for its support., , (2) The minimum distance between plot boundary abutting the street and building other, than a compound wall or fence or outdoor display structure shall be provided as in, Table 3., TABLE 3, , DISTANCE BETWEEN PLOT BOUNDARY ABUTTING THE STREET AND BUILDING, , National Highway , State Highway, District, Roads, other roads notified under section 220(b), of the Kerala Panchayat Raj Act 1994, other unnotified roads with width 6m and above, 3m, , Other un-notified roads with width less, m, , than 6, , 2m, , Provided that in the case of Cul –de –sac of whatever width but not, exceeding 250 m length or pedestrian lanes and streets upto average 3 m width or, internal roads with streets of whatever width within or leading to any residential colony it, shall be sufficient if the distance between the plot boundary abutting the street and, building is 2m for buildings upto 7 m height., Provided further that in the case of lanes not exceeding 75 m length leading to, one or more individual plots it shall be sufficient if the distance between the plot, boundary abutting the lane and the building is 1.5 m., (3) Any restriction under street alignment or building line or both, if any, fixed for area, and restriction under any Master Plan / Detailed Town Planning Scheme/ Interim, Development order in force under the Kerala Town and Country Planning Act, 2016, (9 of 2016)or any other rules or bye-laws shall also apply simultaneously to all, buildings in addition to the provisions contained in sub-rule (1) and (2)., (4) Splay at road junctions, including ‘Y’ junctions shall be splayed as provided below., However original plot boundary can be considered for providing the mandatory yards., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 43
Page 54 :
44, , KERALA PANCHAYAT BUILDING RULES 2019, Sl. No., (1), (2), (3), , Road Width (in metres), Less than 12, Above 12 up to 21, Above 21, , Splay / Offset (in metres), 3X3, 4.5 X 4.5, 6X6, , Provided that for roads with width less than 5 metres, this splay will not be, applicable and when roads of different width form a junction, the respective splay of, the corresponding road in this subrule is considered., , (5) The provisions contained in sub-rules 2 and 3 shall apply invariably to all buildings, where the front, rear or side yard abuts a street or gain access through a street., , 24. Height of buildings - (1), The maximum height of any building or part thereof, shall be limited according to the width of the street as follows:(a), , (b), , The maximum height of the building or part thereof shall not exceed twice the, width of the street abutting the plot plus twice the width of the yard from the, building to the abutting street;, , If a building plot abuts on two or more streets of different width, the building plot, shall be deemed to abut the street that has the greater width for the purposes of, this rule and the height of the building shall be regulated by the width of that, street and shall be continued at this height along the narrower street:, Provided that the height restriction as per this rule shall be compulsory only for, buildings or part of building coming within 12 metres of building line:, , (2) For buildings, structures and installations in the vicinity of airports, the stipulations, with regard to height shall be further limited as subject to any notification issued by, the Government of India under the Aircrafts Act, 1934 (Central Act XXII of 1934), and its amendments from time to time or approved zonal map issued for each airport., The permissible height of the building in this case shall be calculated upto the, highest point of the building without any exemptions., (3) In the case of construction or reconstruction of buildings or alteration or addition to, existing buildings within any Security Zone, the overall height of building upto its, topmost point shall not exceed 10 metres or as specified by the District Collector as, per sub-rule (4) of rule 5, whichever is less:, , Provided that if the overall height of any existing building in the Security, Zone is 10 metres or more upto its topmost point, further vertical extension of that, building shall not be permitted:, Provided further that the height of building shall be measured from the, average level of ground contiguous to the building., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 44
Page 55 :
45, , KERALA PANCHAYAT BUILDING RULES 2019, CHAPTER IV, OCCUPANCY, 25. Occupancy of buildings - (1) All buildings existing or herein after proposed shall be, classified, in one of the following occupancies, according to the use or character of occupancy, namely:—, Group A1, Residential, Group A2, Lodging Houses & Special Residential, Group B, Educational, Group C, Medical/Hospital, Group D, Assembly, Group E, Office, Group F, Mercantile/Commercial, Group G1, Industrial - I, Group G2, Industrial - II, Group H, Storage, Group I, Hazardous, Group J, Multiplex Complex, Notes :(i), , (ii), , (iii), , (iv), (v), , (2), , (a), , Any building not specifically covered by any of the occupancies under sub rule, (1), shall be in the group, which most nearly resembles its existing or proposed, use., Any building other than Multiplex Complex (group J occupancy) building which, accommodates more than one use under sub rule (1) shall be included under the, most restrictive occupancy group. However, occupancy shall be deemed to, include the subsidiary uses which are contingent upon it., The classification of buildings into occupancy groups are only for the purpose of, these rules. The ‘Occupancy group’ is not synonymous with that in the zoning, regulations stipulated in Master Plan / Detailed Town Planning Scheme / Interim, Development Order under the Kerala Town and Country Planning Act, 2016 (9 of, 2016), All occupancies other than Group A1-Resdidential shall be treated as Nonresidential for the purpose of these rules., , Minor occupancy incidental to operations in another type of occupancy shall be, considered as part of the main occupancy and shall be classified under the, relevant group for the main occupancy., , The description of occupancies is given below, namely:-, , Group A1 – Residential Building shall include any building in which sleeping, accommodation is provided for normal residential purposes, with or without cooking, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 45
Page 56 :
46, , KERALA PANCHAYAT BUILDING RULES 2019, , (b), , (c), , (d), , (e), , (f), , and/or dining facilities. They shall include one or multifamily dwellings, apartment, buildings or residential flats. Small professional offices, small household business or, spaces for advocates, doctors, engineers, architects, chartered accountants,, beauticians, tailors, photographers, videographers, telephone booth operators,, computer professionals, typists, electrical or electronic equipment service, professionals, not exceeding 50 sq. metres built-up area and used as part of principal, residential occupancy are also included in this group. Crèches, daycare centres,, children’s nurseries, reading rooms, libraries and educational buildings not, exceeding 200 sq. metres of built up area are also included in this group., Group A2 - Lodging Houses & Special Residential shall include all lodging or, rooming houses, seminaries/convents, orphanage, old age homes, dormitories,, tourist homes, tourist resorts (or by whatever name called), hostels, hotels with or, without conference halls, dining halls or assembly rooms., , Group B - Educational Buildings – These shall include any building or part thereof,, exceeding 200 sq. metres of built-up area, used for school, college, day-care, purposes, other institutions for education or research, libraries incidental to, educational buildings, religious educational building such as madrassa, Sunday, schools & the likeand appurtenant assembly buildings having capacity not exceeding, 200 persons., , Group C - Medical or Hospital Building shall include any building or part thereof,, exceeding 200 sq. metres of built up area which is used for purposes such as medical, or other treatment or care of persons suffering from physical or mental illness,, disease or infirmity, care of infants, hospitals, sanatoria, clinics, homes for the, infirm, convalescent homes, mental hospitals etc, are included in this group., , Group D - Assembly building shall include any building or part of a building, exceeding 200 sq. metres of built-up area where people congregate or gather for, amusement, recreation, social, religious, patriotic, political, civil, travel and similar, purposes such as theatres, motion picture houses or cinemas, assembly halls for, educational, dramatic or theatrical presentations, auditoriums, convention centres,, wedding halls, community halls, exhibition halls, art galleries, museums, libraries,, skating rings, gymnasiums, congregation, dance halls, club rooms, passenger, stations or transport terminals, recreation piers, amusement park structures, viewing, stands, grand stands, stadia and circus tents., Provided that it shall not include multiplexes in which each screen has a seating, capacity less than 300 each., , Group E - Office building shall include any building or part of a building having a, total built up area of more than 200 sq. metres which is used for accommodating, offices of public or private agencies or for keeping of records, accounts and similar, purposes. Local, State and Central Government offices, buildings for office purposes, constructed by private sector and quasi government agencies and buildings for the, use of purposes, court houses, public utility buildings, jails and prisons are included, in this group. All Information Technology Buildings are also included in this group., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 46
Page 57 :
47, , KERALA PANCHAYAT BUILDING RULES 2019, , (g), , (h), , Further, in the case of Government Owned Information Technology Parks,, Government Approved Private Information Technology Parks and Government, Approved Private Information Technology Buildings, all buildings or part of, buildings intended for providing ancillary or support services, amenities and utilities, such as offices, residences, social amenities, recreational facilities, commercial, establishments etc. shall also fall under this occupancy group., Group F - Mercantile or Commercial building shall include any building or part, thereof which is used for display and sale of merchandise such as shops, stores,, markets etc., either wholesale or retail. Banking and financial institutions, business, houses and professional establishments of doctors, dentists, engineers, architects,, lawyers, pathological laboratories, tailor shops, video shops, barbershop, beauty, parlors, newsstands, milk booths, restaurants and non-nuisance type of small, establishments using power motor or machine of capacity not exceeding 3 horse, power are included in this group. Further, buildings or part of building used, exclusively for parking of vehicles (parking buildings, parking plazas etc.) are also, included in this group., Note:-Any building with not more than 200 sq. metres built up area accommodating, the uses under Group C, D,E and H shall be included in Group F., Group G1 – Industrial– I building shall include any building or part of a building or, structure in which products or materials of all kinds and properties are fabricated,, assembled, manufactured or processed and the contents are of such comparative low, combustibility and the industrial processes or operations conducted therein are(i), , (ii), , of such a nature that there are hardly any possibilities for any self, propagating fire to occur; or, , liable to give rise to a fire which will burn with moderate rapidity or result, in other hazardous situation and may give off a considerable volume of, smoke, but from which neither toxic fumes nor explosions are to be feared, in the event of fire., , Note :- Building under Group G1 – Industrial – I occupancy, shall generally,, include Engineering work shops, Automobile service stations, Automobile wash, stalls, Electroplating works, Service garages with repairing facilities, poultry, farms with more than 100 birds, livestock farms with more than 6 dogs, 10 cows, or the like, furniture making units, Cashew factories, oil mills, Fish processing, units, Coir factories, Water treatment/Filtration plants and Water pump houses,, Clock and Watch manufacturing units, Bakeries and biscuit factories,, confectionaries, Food processing units, food catering unit, Electric lamps, (incandescent and fluorescent) and T.V. tube manufacturing units, Dry cleaning,, dyeing and laundry units, Flour mills, Manure and fertilizer works (blending,, mixing and granulating only) units, Oxygen plants, Plastic goods manufacturing, and PVC pipe manufacturing units through injection/extrusion moulding,, printing press, rubber goods manufacturing units, manufacture of synthetic, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 47
Page 58 :
48, , KERALA PANCHAYAT BUILDING RULES 2019, , (i), , leather, spray painting units, and textile mills; all up to 700 sq. metres total built, up area., , Group G2– Industrial– II building shall include any building or part of a building or, structure in which products or materials of all kinds and properties are fabricated,, assembled, manufactured or processed in which the contents or industrial processes, or operations conducted therein are liable to give rise to a fire which will burn with, extreme rapidity or result in other hazardous situation or from which poisonous, fumes or explosions are to be feared in the event of a fire., Note (1): - Building under Group G2 - Industrial – II occupancy, shall generally,, include Bituminized paper/ hessian cloth/ tar felt manufacturing, Cinema films and, T.V. production studios, cotton waste factories, modern meat processing unit, /slaughter houses wherein facilities mentioned in the Kerala Panchayat Raj, (slaughter house and meat stalls) Rules, 1996 are provided, Electric and gas, crematoria, distilleries, tyre retreading and resolving factories and petroleum, refineries and LPG bottling plants., , (j), , (k), , Note (2):- For the purpose of these rules, all buildings with total built up area, exceeding 700 sq. metres, under uses mentioned in item (h) above shall be included, in Group G2 - Industrial – II occupancy., , Group H - Storage building shall include any building or part thereof used primarily, for the storage or sheltering (including servicing, processing or repairing incidental, to storage) of goods, wares or merchandise (except those involving highly, combustible or explosive products or materials), vehicles and the like. Warehouses,, freight depots, transit sheds, storehouses, garages, hangars, grain elevators, barns and, silos are included in this group. Minor storage incidental to other occupancies shall, be treated as part of the predominant occupancy., Group I - Hazardous building shall include any building or part of a building which, is used for the storage, handling, manufacturing or processing of highly combustible, or explosive materials or products which are liable to burn with extreme rapidity, and/or which may produce poisonous fumes or explosions; for the storage, handling,, manufacturing or processing which involve highly corrosive, toxic or noxious, alkalis, acids or other liquids or chemicals producing flame, fumes and explosive,, poisonous, irritant or corrosive gases; and for the storage, handling or processing of, any material producing explosive mixtures of dust which result in the division of, matter into fine particles subject to spontaneous ignition., Any process or activity, where raw materials used therein or wastes or effluents, thereof would result in the pollution of the general environment are also included, under this group., , Building under Group I – Hazardous occupancy shall generally include buildings, and yards used for storage under pressure of more than 1Kg/cm2 and in quantities, exceeding 70 m3 of acetylene, hydrogen, ammonia, chlorine, phosgene, sulphur, dioxide, carbon monoxide, methyl oxide and all gases subject to explosion, fumes or, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 48
Page 59 :
49, , KERALA PANCHAYAT BUILDING RULES 2019, toxic hazard; Godowns or warehouses (combustible / hazardous goods), storage and, handling of hazardous and highly inflammable liquids, oil terminals/depots and bulk, storage of flammable liquids, crematoria, burial grounds, vaults, garbage dumping, yards, abattoirs (slaughter houses), sewage treatment plants of capacity more than, 100 KLD, stone crusher units, hot mixing plants of permanent nature (intended to, function for more than six months), ready mix concrete plant (intended to function, for more than six months), automobile fuel filling stations, coal, wood and timber, yards, saw mills., , (l), , Sewage treatment plant of capacity less than 100 KLD and constructed as part of the, main building, shall be treated as an ancillary building of the main use., , Group J: - Multiplex complex shall mean an integrated entertainment and shopping, centre/shopping complex or a shopping mall, having more than one cinema hall, /screens each with seating capacity of 300 or less. Apart from cinema halls, the, entertainment area may have restaurants, cafeteria, fast food outlets, video games, parlours, pubs, bowling alleys, health spa/centres, convention centres, hotels, other, recreational activities and all other permissible uses under Group F. However,, habitable areas like hotels and service apartments shall not be allowed in the same, block where the multiplexes are set up and shall be allowed only as a separate block., Such a complex may spread over the site or be in one or more blocks which may be, high-rise buildings or normal buildings. The total built up area of multiplex complex, shall not be less than 12,000 sq. metres and the height of building shall not exceed 50, metres., , 26. Exterior and Interior open air spaces - (1) Every room intended for human habitation, shall abut on an exterior or interior open space or verandah open to such exterior or interior, open space and such open space shall be maintained for the benefit of the building, exclusively and shall be entirely within the owner's own premises and shall be open to the sky, and is barred from being subdivided, partitioned or legally bifurcated or transacted, in any, manner whatsoever, till such date when the structure itself is demolished and shall be kept, free from any erection thereon other than those specially allowed in these rules., (2) In the case of buildings with multiple occupancy other than multiplex complex, yards for, the most restrictive occupancy shall be provided., (3) The required minimum setbacks shall be provided at the ground level itself for the whole, building., (4) The minimum yards for every building upto 10 metres in height shall be as per the Table, 4:-, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 49
Page 60 :
KERALA PANCHAYAT BUILDING RULES 2019, TABLE 4, , YARDS FOR BUILDINGS UNDER DIFFERENT OCCUPANCIES, Buildings, in Group, A1& A2, of any, built-up, area and, Buildings, Yards, in Group, F with, built up, area not, exceeding, 200 sq., metres, (1), , Front, (in, metre), Rear, (in, metre), Sides, (in, metre), , Buildings, in Small, plots, under, Group A1, and F, (built up, area not, exceeding, 200 sq., metres, and plot, area not, exceeding, 125 sq., metres), , Group, G1, built, up, area Buildings, Group E upto in Group, &F built 200, G1 of, up area, sq., built up, exceeding metres, area, exceeding, 200 – Above 200 sq., metres, 200 sq., 500, 500, metres, sq., sq., metres metres, Buildings in, Group B, C &, D of built-up, area exceeding, 200 sq. metres, , Buildings, in Group, H of built, up area, exceeding, 200 sq., metres, , (3), , (4), , (5), , (6), , (7), , (8), , (9), , (10), , 3, , 2, , 5, , 7.5, , 3, , 3, , 3, , 7.5, , 6, , 7.5, , 10, , 1.5, , 1, , 2, , 3, , 1.5, , 2, , 3, , 5, , 3, , 7.5, , 5, , 1, , 0.6, , 2, , 3 and 5, , 1, , 2, , 3, , 3, , 2, , 7.5, , 5, , (2), , Group I, , Group J, , Group G2, , 50, , (11) (12), , Provided that for single family residential buildings the front yard of plots abutting unnotified roads with less than 6 m , shall not be less than 2 m., Provided further that any one yard other than front yard of a building referred in column(2), and (3) in Table 4 can be reduced upto 50 centimetres if there is no opening on that side., , Provided also that in the case of appurtenant buildings used exclusively for the parking, purpose of the main building and constructed in the same plot, the open yard abutting the street, shall have minimum 3 metres and other sides shall have minimum 1 metre for buildings upto 10, metres in height and additional open space corresponding to height of the building shall be, provided at the rate of 50 centimetres for 3 metres height or part thereof at the ground level itself., Such appurtenant building may abut the main building but the light and ventilation of the main, building shall not be reduced below the required minimum by such abutting., , Provided also that unless otherwise specified in a Master Plan / Detailed Town Planning, Scheme/ Interim Development order in force under the Kerala Town and Country Planning Act,, 2016 (9 of 2016) , side yards may not be provided for buildings under group F mercantile or, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 50
Page 61 :
51, , KERALA PANCHAYAT BUILDING RULES 2019, commercial occupancy, other than high rise buildings, in an area exclusively zoned for, commercial use in such plan / scheme / order, if the owner of the plot abutting the property under, construction voluntarily agrees for the same in writing., Provided also that for Group A1, A2 and F occupancy buildings upto two floors, any one, side yard and/or rear yard can abut the boundary other than that of a street with the written, consent of the adjoining land owner. If one land owner voluntarily agrees to abut the building in, the neighbouring plot to his plot boundary, then the land owner may, also have the right to abut, his building to the same plot boundary without a written consent., (5) In case a group of buildings are to be put up within any plot belonging to the same owner, or by different owners of adjoining lands jointly, the area of the land remaining after, accounting for the mandatory front, rear and side yards from the boundary of the plot shall, be considered as buildable area of the plot, and the minimum distance between any two, buildings up to 10 metres height shall be 2 metres and for building(s) above 10 metres in, height, the distance between two buildings shall be 3 metres., (6) For buildings above 10 metres in height, in addition to the minimum front, rear and side, yards and the minimum width of interior open space required for height upto 10 metres,, there shall be provided increase in such minimum yard at the rate of 0.5 metre per every 3, metres height or fraction thereof exceeding 10 metres at the ground level itself, until the, total width of yard reaches 16 metres and no further additional setback is required for, additional height above this., (7) Any room intended for human habitation and not abutting open air spaces on the front, rear, or side shall abut on an interior open space whose width shall not be less than 2.4 metres:, (8) At least 50% of the total open space in the plot shall be left unpaved or, paved with suitable, materials enabling percolation of rain water., (9) No construction or hanging of any sort shall be permitted to project outside the boundaries, of the site., , (10) Every mandatory open space/yard provided as per these rules, either interior or exterior,, shall be kept free from any erection thereon such as Generators, AC plant room,, recreational space and the like, and shall be open to the sky, and only cornice, roof or, weather shade not more than the width specified in Table 5 below, shall overhang or, project over the said mandatory open space/yard., , Sl.No., , TABLE 5, PROJECTIONS PERMISSIBLE, , Mandatory open space/yard as per these rules., , Width of projection, permissible, , 1, , below 0.60 metres, , No projection, , 3, , 1 metre or more but below 1.50 metres, , 2, 4, , 0.60 metres or more but below 1 metre, , 0.30 metres, , 1.5 metres and above, , 0.75 metres, , 0.60 metres, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 51
Page 62 :
52, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that when the open space /yard actually provided is more than the, , minimum prescribed as per these rules, the width of cornice, roof or weather shade shall be, permitted corresponding to the increase in the open space/yard provided., , Provided further that no door or window shall be permitted if the open space on that, , portion is less than 1 metre. However ventilator opening may be made above a height of, 2.1metres from the corresponding floor level if the open space on that side is at least 0.60, metres., , Provided also that in the case of construction of buildings in small plots and building, , construction as per approved schemes of these rules, windows shall be permitted if the open, space on that side is at least 0.60 metres., , Provided also that flight of steps or ramps, all open to sky, with or without parapets, , or railings meant as access to upper or lower floors shall be permitted in the open space if, such stair, step or ramp has minimum 0.60 metres distance from the boundaries., , Provided also that the underneath of such flight of steps or ramp, shall not be, , enclosed however pillars may be permitted for its support., , (11) The front, rear and side setbacks for constructions below the ground level shall be the same, as that required for a 10 metre high building of the same occupancy group constructed, above ground level., , 27. Coverage and Floor Space Index.(1), , The maximum percentage of coverage permissible for each occupancy shall limit the, foot print of a building. The Floor Space Index value shall limit the maximum buildable, area. Floor Space Index i.e., F.S.I. shall be calculated as shown below:, . . =, , Note: - (1) The area of plot to be taken for the calculation of floor space index and coverage, shall be the total plot area without deducting the area required from the plot for any, proposed road widening stipulated in statutory Town Planning Schemes/Plans under the, Town and Country Planning legislation in force, unless otherwise stipulated specifically, in such schemes., , (2), , The percentage of coverage and the F.S.I value of buildings under different occupancies, shall not exceed the maximum specified as in Table 6 below:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 52
Page 63 :
KERALA PANCHAYAT BUILDING RULES 2019, , 35, , 35, , 4, , Medical/Hospital C, , 50, , 5, 6, 7, 8, 9, , 10, 11, 12, , Others, , Assembly D, Office E, Mercantile/Commercial F, Industrial-I G1, , Industrial-II G2, , Storage H, Hazardous I, Multiplex complex J, , 65, , 5, 3, , 55, , 2.5, , 50, , 45, , 2.5, , 40, 60, 65, , 35, 50, 60, , 1.5, 3, 3, , 60, 40, 70, 45, 65, , 45, , 50, 35, 65, 40, 60, , 2.5, , 2.5, , 3.5, 3, 3, 2, 3, , 4, , 1. 5, , 2.25, , 3, , 1.5, , 1.75, , 2.5, 4, 4, , 0.7, 3, 2.75, , 1.25, , 2.5, , -, , 6, 4, 3, , 3.5, , 4, 3.5, , 7, 2.5, 1.5, , 2.5, , 2.75, 2.75, 2, 2.5, , With additional fee of Rs 5000 per, sq. metre for the additional area, , 4, 60, , Without additional fee, , 3, 65, , 3, , 2, Residential A1, Lodging, Houses&Special, Residential A2, Upto, Higher, Secondary, Educat-ional B, , Category - II, Maximum, permissible F.S.I., , With additional fee of Rs 5000 per, sq. metre for the additional area, , Maximum permissible Coverage – Category II, , 1, 1, 2, , Category - I, Maximum, permissible F.S.I., , Without additional fee, , Sl., No., , Maximum permissible Coverage - Category I, , TABLE 6 : COVERAGE AND FLOOR SPACE INDEX (F.S.I), , Occupancy, , 53, , 8, , 1.75, , 3.5, -, , 3.75, 3, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 53
Page 64 :
54, , KERALA PANCHAYAT BUILDING RULES 2019, (i), , (ii), , (iii), (iv), , (v), , (vi), , (vii), , The value of maximum permissible coverage of a building of a particular occupancy, group shall be limited by the value given under column (3) and shall be the maximum, area covered by the building at any storey, fully or partly above ground level after, accounting for the exterior open spaces (front, sides and rear) and interior open spaces., , For apartments / flats under Group A1 – Residential occupancy by Government or, Quasi Government agencies of Joint venture with Government aimed at housing, economically weaker sections (EWS) and or lower income groups (LIG) and Centrally, Sponsored Housing Schemes for EWS, a maximum F.S.I. of 5 shall be permitted, without additional fee, if built-up area of each and every dwelling unit in it is less than, 100 sq. metres. Classification of income groups and matters related to the same shall be, decided by the Government in consultation with the Committee constituted under the, provisions of Chapter IX of these rules., In the case of buildings used exclusively for worships, the maximum permissible, coverage shall be 50 per cent., , In the case of Government owned Information Technology Parks, Government, approved private Information Technology parks, Government approved private, Information Technology buildings under Group E occupancy, the maximum, permissible F.S.I. shall be 4 and the maximum permissible coverage shall be 60%. The, additional fee prescribed in Table 6 shall not be applicable in such cases., In the case of multiple occupancy buildings, required plot area is calculated for each, floor separately taking in to account each occupancy in the floor based on the, permissible coverage values as per these rules. Coverage shall be considered, satisfactory only if such maximum among the calculated plot area for each floor is less, than or equal to the actual plot area., , In the case of a group of buildings within any plot, required plot area is calculated, individually for each building in the plot based on the permissible coverage values as, per these rules and the sum of the plot area so calculated is compared with the actual, plot area. Coverage shall be considered satisfactory only if the calculated plot area is, less than or equal to the actual plot area., , In the case of a multiple occupancy building as well as a group of buildings within a, plot other than Group G2, I and J occupancies, the maximum permissible Floor Space, Index shall be the weighted average of the Floor Space Index under the respective, occupancies; weightage for each individual occupancy being the built-up area under, each such occupancy and the total weightage being the sum total of built-up area of, such building(s)., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 54
Page 65 :
55, , KERALA PANCHAYAT BUILDING RULES 2019, Weighted F.S.I. = [f1 x A1 + f2 x A2 + f3 x A3 + .................... ] / A, Where:, , f1, f2, f3 . . . . . . . . - denote the maximum permissible F.S.I. of different, occupancies in the building(s) within the plot,, , A1, A2, A3,........ . .- denote the built-up areas under respective occupancies, in the building(s) within the plot; and, , A -, , denotes the total built-up area of the building(s) and is, equal to A1 + A2 + A3 + . . . . . .., , 28 Access - (1) The minimum width of access to a building and plot as well as the minimum, width of the existing street giving access to the plot from the main street shall be as shown in, Table 7 and 8, unless otherwise specifically mentioned elsewhere in these rules. The width of, the main street shall not be less than the minimum width of access to the building and plot as, well as width of street giving access to the plot., TABLE 7, ACCESS FOR GROUP A1, A2, B, C, E AND F OCCUPANCIES, Total built-up area in sq. metres, Minimum access, width in metres, Group A1, Group A2,B,C, E & F, Up to 200, -No minimum, Above 200 upto 400, Upto 200, 1.5, Above 400 upto 4000, Above 200 upto 1500, 3.6, Above 4000 upto 8000, Above 1500 upto 6000, 5, Above 8000 upto 24000, Above 6000 upto 18000, 7, Above 24000, Above 18000, 10, TABLE 8, ACCESS FOR GROUP D, G1, G2, H, I AND J OCCUPANCIES, Sl.No Total Built-up area, in sq. metres, 1, 2, 3, 4, 5, 6, , Upto200, Above 200 upto, 500, Above 500 upto, 700, Above 700 upto, 4000, Above 4000, Multiplex complex, (above 12000), , Minimum access width in metres, Group D and H, , Group G1, , 1.5, 3.6, , 3, 3.6, , 5, , 5, , 7, , 7, 10, , Group, G2 & I, 7, , Group J, , Not, applicable, , 12, , Provided that the access width of any building shall be modified to be in, accordance with the provisions in any Town Planning Scheme for the area:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 55
Page 66 :
56, , KERALA PANCHAYAT BUILDING RULES 2019, Provided further that other than for high rise buildings, in case there is, deficiency as per provisions of these rules, in minimum width of the existing street, giving access to the plot from the main street, at one or two short stretches (the total, length of the street with reduced access width shall not be more than 1/4th of the total, length of the street or 25 metres whichever is less), the Secretary, if convinced that the, movement of vehicles and traffic will not be seriously affected, may allow a tolerance, upto twenty centimetres in the minimum width of street at such stretches, required as, per these rules., Provided also that wherever off-street car parking is required for the, building as per these rules, motorable access of width not less than 3metres shall be, provided to the building and plot., , Provided also that in the case of A1 occupancy, it is necessary that if the, number of units is not more than 8, then the width of such motorable access to off-street, car parking shall not be less than 2.4 metres., Provided also that in the case of automobile service stations, automobile, wash stalls or service garages, all with repairing facilities under Group G1 occupancies,, the access width shall not be less than 7 metres., Provided also that in the case of all livestock and poultry farms, the access, width shall not be less than 1.2 metres if the total built up area is upto 500 sq. metres, 3, metres if the total built up area is above 500 sq. metres but upto 1000 sq. metres and 5, metres if the total built up area is above 1000 sq. metres., Provided also that in the case of vaults, crematoria or burial grounds, the, access width shall not be less than 3 metres., , Provided also that in the case of fuel filling station intended only to fuel, boats and the like, the access width shall not be less than 5 metres., , Provided also that in the case of type C Magazines as per the provisions, containing in the Explosives Rules, 2008, such width shall not be less than 3.6 metres., , Provided also that internal access to an individual building shall be the, mandatory access width required as per Table 7 and 8 above. An internal access can be, through the mandatory open space of a building in any occupancy, in the group of, buildings, provided the minimum distance between the building and the street giving, access to the building shall be 3 metres for high rise buildings and 2 metres for other, buildings., Provided also that such internal street may be permitted in the open spaces, which are not used for other mandatory uses such as off-street parking, recreational, open space, loading/unloading space etc. specified in these rules., Provided also that in the case of Government and aided schools upto higher, Secondary (including Vocational Higher Secondary) level, the existing access and, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 56
Page 67 :
57, , KERALA PANCHAYAT BUILDING RULES 2019, street shall be sufficient for carrying out the following constructions, reconstruction,, addition or alteration of building(s) in the plot, namely:, (i) any addition of toilet blocks and other sanitation arrangements., (ii) other building works without increase in the total built-up area of all the, buildings put together in the plot prior to carrying out such works., , Provided also that in the case of all existing schools upto the level of Higher, Secondary, including Vocational Higher Secondary, if the total built up area of the, construction(s) including existing and proposed does not exceed 5000 sq. metres, 3.6, metres access shall be sufficient., Provided also that in the case of high rise buildings, the minimum width of, access shall be the width as stipulated in Chapter XVII of these rules., , Provided also that in the case of modern meat processing unit /slaughter, houses and Electric and gas crematorium in Group G2 occupancy, 5metres access shall, be sufficient., , (2), , (3), , (4), , (5), , (6), (7), , (8), , In the case of access to the multiple occupancy building, the minimum width of, access to a building and plot as well as the minimum width of existing street giving, access to the plot from the main street shall be the minimum width of access, required for the total built-up area of the building taken together as the most, restrictive occupancy for the purpose of this rule., , In the case of a group of buildings within any plot, the minimum width of access to, the plot as well as the minimum width of existing street giving access to the plot, from the main street shall be the minimum width of access required for the total, built-up area of all the buildings taken together as the most restrictive occupancy, for the purpose of this rule., No person shall at any time construct or cause or permit to construct or reconstruct, any building which in any way encroaches upon or diminishes the area set apart as, access to that building., , No person shall construct a building or undertake construction work on a building, which reduces the access to any building previously existing, below the minimum, width required under these rules., No building shall be constructed so as to deprive any other building of an existing, access., Every access shall be drained and lighted to the satisfaction of the Secretary and, manhole covers or other drainage, water or any other fittings laid in such access, shall be flush with finished surface level so as not to obstruct safe travel over the, same., The clear headroom for motorable access within the plot shall not be less than 5, metres., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 57
Page 68 :
58, , KERALA PANCHAYAT BUILDING RULES 2019, (9), , Waterway other than sea routes will be considered as an access to islands as per, these rules, if the following conditions are satisfied:(a) Waterway which is considered as access to the island shall be navigable., (b) Road access as per these Rules shall be provided upto the public boat, landing/jetty area except for single family residential buildings., , (c) Approval shall be obtained from the Fire and Rescue Services Department., , 29. Parking, loading and unloading spaces - (1) Area of each off-street parking space provided, for parking motor cars shall not be less than 15 sq. metres, length of the parking bay shall not, be less than 5.5 m., (2), (3), , For buildings of different occupancies, off-street parking spaces for motor cars shall be, provided within the plot as specified in Table 9 and 10 as the case be., Parking requirement is calculated based on built-up area. The area provided for parking, inside the building shall not be taken into account while calculating the built-up area for, assessing the parking requirement of the building., , TABLE 9, OFF-STREET PARKING SPACE FOR APARTMENTS/FLATS UNDER GROUP-A1, Built up Area per Dwelling Unit, , Upto 75 sq. metres, Above 75 sq. metres upto 185 sq. metres, Above 185 sq. metres upto 300 sq. metres, Above 300 sq. metres, , Off-street Parking Spaces at the rate of, , 1 for every 3 dwelling units, 1 for every dwelling unit, 1.5 for every dwelling unit, 2 for every dwelling unit, , Note: Fractions if any in the total number of parking worked out shall be rounded off to the next, whole number. In addition to the above, additional car parking space has to be provided inside the, plot if required and on-street parking will not be permitted., TABLE10, OFF-STREET PARKING SPACE FOR OCCUPANCIES OTHER THAN GROUP-A1, Sl. No Occupancy, (1), 1, , One parking space for every or fraction of, (2), , Group A2-Lodging houses & Special, Residential, , (3), , 90 sq. metres of built-up area for buildings, having total built-up area upto 1260 sq. metres, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 58
Page 69 :
59, , KERALA PANCHAYAT BUILDING RULES 2019, and 60 sq. metres of built-up area for the total, built-up area in excess of 1260 sq. metres., 2, , Group B-Educational, (i) High Schools, Higher Secondary (i) 300 sq. metres of built-up area., Schools, Junior Technical Schools,, Industrial Training Institute etc., (ii) 125 sq. metres of built-up area, (ii) Higher educational institutions, , 3, 4, , Group C- Medical/Hospital, Group D- Assembly, , 5, , Group E- Office Building, , 6, , Group F- Mercantile/ Commercial 90 sq. metres of built-up area for buildings, building exceeding 75 sq. metres built- having total built-up area upto 1260 sq. metres, up area, and 60 sq. metres of built-up area for the total, built up area in excess of 1260 sq. metres., , 7, , Group G1- Industrial-I Building, , 250 sq. metres of built-up area, , 8, , Group G2- Industrial– II Building, , 250 sq. metres of built-up area, , 9, , Group H-Storage, , 250 sq. metres of built-up area, , 10, , Group J Multiplex complex, , 60 sq. metres of built-up area, , ., , 90 sq. metres of built-up area, 25 sq. metres of built-up area, Note:(i), In the case of wedding halls and, community halls, for calculating the, built-up area for the purpose of, parking, the built-up area of either, the auditorium or the dining hall,, whichever is higher, alone need be, taken., (ii), In the case of library, for calculating, the built-up area for the purpose of, parking, the area of the stacking, space for books shall be excluded., 90 sq. metres of built-up area for buildings, having total built up area upto 1260 sq. metres, and 60 sq. metres of built-up area for the total, built up area in excess of 1260 sq. metres., , Provided that in the case of a building/building complex accommodating more than one, occupancy, parking as above shall be made available in the same plot itself, earmarking the, occupancy wise parking areas as detailed in Table 9 and 10 for the respective occupancies:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 59
Page 70 :
60, , KERALA PANCHAYAT BUILDING RULES 2019, Provided further that, in the case of Government Owned Information Technology Parks,, Bio Technology buildings / Parks, Government Approved Private Information Technology Parks, and Government Approved Private Information Technology Buildings under Group E, occupancy, the off-street car parking requirement shall be at the rate of one parking space for, every 120 sq. metres of built-up area or fraction thereof., (4) Every off-street parking space shall be provided with adequate vehicular access to a street,, area of drives, aisles and such other provisions required and adequate area for, maneuvering of vehicles in addition. Such drives, ramps, aisles intended for vehicular, movements shall satisfy the following:, (i), , (ii), , (iii), (iv), (v), (vi), , Drive way leading to off-street parking space shall have width not less than 3, metres and shall be motorable. But in the case of A1 occupancy, if the number of, units is not more than 8, then the width of such motorable access to off-street car, parking shall not be less than 2.4 metres., , Width of ramp for driveway for one-way direction shall not be less than 3.5, metres, 5.5 metres for two-way direction and at curves it shall not be less than 4, metres and 6 metres respectively, and slope of such ramps shall not be steeper, than 1: 7., The width of vehicular passage for rows of parking for motor cars shall not be, less than 4.5 metres, The headroom for the drive way, ramps, passage etc. for motor car movement, shall not be less than 2.2 metres at any point., The headroom of floors exclusively used for parking of cars and two wheelers, shall not be less than 2.2metres., Minimum turning radius of 9 metres to be provided for fire tenders., , (5) Wherever any off-street parking space is required under these rules, 25% of that area, shall be provided additionally for parking two wheelers., (6) In the case of apartments/flats, 15% of mandatory off-street parking space as in Table 9, shall be provided additionally, earmarked and maintained exclusively to accommodate, visitors’ parking., , (7) In addition to the parking space as in Table 10, in the case of Group F Mercantile or, Commercial, Group G1- Industrial-I and Group G2- Industrial-II and Group H - storage, occupancies, loading and unloading spaces each 30 sq. metres shall be provided within, the plot, at the rate of one such space for each 1000 sq. metres of built-up area or fraction, thereof, exceeding the first 700 sq. metres of built-up area., , (8) Not exceeding fifty percent of each mandatory open yard shall be taken into account for, calculating the required parking space if such open yard has adequate vehicular access, and area for maneuvering., (9) The minimum mandatory open spaces around any building(s) as well as mandatory, parking spaces as per these rules shall not be sold or let out for parking of vehicles other, than that for the building(s)., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 60
Page 71 :
61, , KERALA PANCHAYAT BUILDING RULES 2019, (10) Of the mandatory off-street car parking requirement as per these Rules, fifty per cent at, the maximum may be provided for by mechanised parking, on condition that the, owner/occupant shall ensure proper safety, structural stability and functioning of such, mechanized parking system at all times. Minimum headroom of parking lot in, mechanized parking shall not be less than 2 metres., (11) In case of exclusive mechanized parking facility the proposed facility may abut building, and/or 1 m from the boundaries irrespective of height of the facility., , 30.Approval for layout of buildings and usage of plot:- Approval of the District Town Planner or, the Chief Town Planner, as the case may be, shall be obtained for the usage of plots and lay, out of buildings with area/dwelling units as stipulated in Table 11., TABLE 11, APPROVALS FROM TOWN AND COUNTRY PLANNING DEPARTMENT, , (a), (b), (c), , (d), , (e), , Buildings requiring approval of, Occupancy, District Town Planner, Chief Town Planner, (1), (2), (3), Apartments (Group A1) Building(s) with number of, dwelling units exceeding 100, Lodging houses &, Building(s) with total built-up, Special Residential, area exceeding 8000 sq., (Group A2), metres., Educational (Group B) , Building(s) with total built-up, Medical/Hospital, area exceeding 1500 sq., (Group C), Assembly, metres., (Group D) & Office, (Group E), Commercial (Group F) Building(s) with total built-up, area exceeding 8000 sq., metres., Group G1 Industrial-I & Building(s) with total built-up, Group G2 Industrial-II area exceeding 1500 sq., metres, , (f), , Storage and, warehousing (Group H), , (g), , Hazardous (Group I), , (h), , Multiplex Complex, (Group J), , Building(s) with total built-up, area exceeding 6000 sq., metres., All Hazardous buildings, --, , All buildings under this, occupancy group, , Note: - In Table 11 above, built-up area includes the area of existing and proposed, buildings., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 61
Page 72 :
62, , KERALA PANCHAYAT BUILDING RULES 2019, Provided further that in the case of Type C Magazines as per the provisions contained in the, Explosives Rules 2008, such approval of the District Town Planner or Chief Town Planner is, not necessary. However, all other mandatory clearances applicable for such constructions, shall be obtained., , 31. Land sub-division and plot development.1. For residential use: -, , All new land subdivisions and plot developments shall be subject to the following, namely:(i), , (ii), , the area of any newly subdivided plot, reconstituted plot or building plot shall be, not less than 125 sq. metres with an average width of 6 metres:, , Provided that for row housing where side open spaces are not required, it is, sufficient if the plot has an average width of 4.5 metres;, every plot shall have a frontage of not less than 4 metres on any abutting street;, , (iii) every street in the layout shall have not less than 7 metres width and shall be, motorable;, , Provided that in the case of cul-de-sacs with length not exceeding 250 metres it is, sufficient if the street (cul-de-sac) has not less than 5 metres width;, Provided further that in residential areas where motorable street cannot be made, due to difficult terrain, the width of any new street shall not be less than 5metres, and where the length of such street does not exceed 250 metre it is sufficient if, the street has not less than 3metres width;, , (iv) the minimum existing width of the street giving access to the land proposed for, subdivision from the main street shall be as given in Table 12:, , S l., No, 1, 2, 3, 4, , TABLE 12, WIDTH OF STREET, , Total extent of land, Upto 0.5 hectares, , More than 0.5 hectares upto 1 hectares, More than 1 hectare upto 2 hectares, More than 2 hectares, , Minimum width required, (in metres), 1.5, 3.6, 5, 6, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 62
Page 73 :
63, , KERALA PANCHAYAT BUILDING RULES 2019, (v), , when the area of the land under development work, layout or subdivision, exceeding ten plots is 0.5 hectares or more, ten percent of the total area shall be, provided for recreational open spaces and shall be suitably located to be, accessible to the residents of the layout;, provided that while considering the area of the land, the area of any contiguous, land belonging to the same owner, though not proposed for immediate, development shall be taken into account;, , (vi) the recreational open space to be provided under item (v) shall have an access as, if it were a separate plot and as far as possible it shall be in one piece and in no, case less than 2 Ares in area with a minimum width of 6 metres;, (vii) the layout or subdivision proposal shall be in conformity with the provisions of, Master Plan / Detailed Town Planning Scheme/ Interim Development Order, if, any, in force under the Kerala Town and Country Planning Act, 2016 (9 of 2016),, and if the land is affected by any reservation for a public purpose, the Secretary, may agree to adjust its exact location to suit the development but not so as to, affect its area;, , (viii) the street junctions shall be splayed or rounded off to give sufficient turning radii, and sight distance for vehicles and the side of the splay shall be a minimum of 4, metres for roads up to 10 metres and shall be a minimum of 10 metres for roads, exceeding 10 metres width as shown in the figure below:, , (ix) in the case of lay out or sub division of land having an area of two hectares or, more a suitable location for an electric transformer shall be provided;, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 63
Page 74 :
64, , KERALA PANCHAYAT BUILDING RULES 2019, (x) in the case of layout for subdivision of land, where the number of residential plots, exceeds 10 and plot area less than 0.5 hectare approval of the Secretary, Local, Self Government Institution shall be obtained as per the provisions of this rule., (xii), , in the case of layout for subdivision of land, where the number of residential plots, exceeds 20 or if the area of the land is above 0.5 hectare approval of the District, Town Planner shall be obtained., , (xiii) if the site forms part of approved layout, copy of sub division layout shall be, enclosed along with the plans for approval;, (xiv) adequate arrangements for surface water drainage shall be provided with suitable, drains etc;, (xv), , for the entire period of land development, the owner shall display the details of, the permit near the entrance to the site in a board of size not less than 100, centimetres x 75 centimetres. The details to be displayed include name and, address of the owner and developer with phone number, details of plots such as, number, area and use, the area and location of recreational open spaces, road, widths, number and date of approval of the District Town Planner/Chief Town, Planner, number and date of the permit and the name of Local Self Government, Institution; and, , (xvi) In the case the number of plot of layout for subdivision exceeds 10, any yard, adjoining internal road/street of building(s) upto 10 metres height can be reduced, to 2 metres., , 2. For industrial use: (i), , (ii), , All new land sub- divisions and plot developments shall be subject to the following:-, , the width of every new street, public or private, intended for use as a motor way, giving access to or through an organized industrial area with not less than six, constituent units, shall be minimum 10 metres;, Provided that in the case of Group G1 Industrial-I units or cul-de-sac not, exceeding 250 metres length, the minimum road width shall be 7 metres., , the minimum size of industrial plot abutting street shall be 400 sq. metres in, extent with a width of not less than 15 metres;, Provided that the minimum plot requirement in item (ii) shall not apply to Group, G1 Industrial-I units;, , (iii) in industrial layouts a place for installation of transformer shall be provided;, , (iv) The approval of the District Town Planner shall be obtained for the layout of, industrial streets and land sub-division exceeding five plots, (v) the usage of plots proposed for development or redevelopment shall be governed, by the provisions contained in the Master Plan / Detailed Town Planning Scheme/, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 64
Page 75 :
65, , KERALA PANCHAYAT BUILDING RULES 2019, Interim Development Order, if any, in force under the Kerala Town and Country, Planning Act, 2016 (9 of 2016)prepared for the locality;, Provided that where no such plan exists, the usage of plots shall be as approved, by the District Town Planner or an officer authorized by him., 3. For mercantile (commercial) use :-, , All new land sub-divisions and plot developments shall be subject to the following: (i), , (ii), , the width of every new street, public or private, intended for use as motor way, giving access to or through a commercial precinct consisting of a continuous, row of shops exceeding ten in number shall not be less than 10 metres except in, the case of cul- de-sac not exceeding 150 metres length, where the minimum, width shall be 7 metres;, , the frontage of every commercial plot abutting the street, shall have a minimum, width of 6 metres;, , (iii) the minimum size of plot within a layout proposed for commercial development, shall not be less than 60 Sq. metres;, , (iv) for every plot within a layout for commercial development, building line from the, street shall not be less than 3 metres;, (v), , (vi), , no plot intended to house a service garage or auto workshop within a layout for, commercial development shall be of an area less than 300 sq. metres and an, average plot width less than 12 metres; and, The approval of the District Town Planner shall be obtained for the layout of all, new Commercial Street and land sub-division exceeding five plots., CHAPTER V, PARTS OF BUILDING, , 32., , 33., , Mezzanine floor.-(1), The built-up area of mezzanine floor shall not exceed one, third area of the main floor or room accommodating the mezzanine floor., (2) The clear headroom beneath and above the mezzanine floor shall not be less than, 2.2 metres., Height of room.-, , The height of room intended for human entry in a building other than residential, occupancy and livestock/poultry farm shall not be less than 3 metres:, , Provided that in the case of air conditioned rooms it shall not be less than 2.4 metres., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 65
Page 76 :
66, , KERALA PANCHAYAT BUILDING RULES 2019, 34., , Sanitation Facilities:-, , (1) Size of bathroom and latrine.-, , (1) The area of bathroom shall not be less than 1.50 sq.metres with either side not less, than1.1m, area of a latrine shall not be less than 1.10 sq. metres with one side not, less than 1.0 metre:, Provided that the area of combined bathroom and latrine shall be not less than 2.2, sq. metres with one side not less than 1. 1 metres:, , (2) The height of bathroom or latrine shall be not less than 2.20, metres., , (2) Water closet.-Every building above 50 square metres of built up area shall be, provided with at least one water closet., (3) Calculation of sanitation facilities, , (1) Sanitation facilities to be provided for occupancies other than Group A1shall be, provided in numbers not less than those stipulated in Table 14 and Table 15, as, the case may be. The occupant load for this purpose shall be computed at the, rate given in Table 13., TABLE 13, , OCCUPANT LOAD FOR CALCULATING SANITATION REQUIREMENTS, Sl.No, , Occupancy, , Built-up area in sq.metres/person, , 1, Group A2, B, C,E and F, 5.9, 2, Group D and J, 1.8, 3, Group G1 , G2 , H and I, 30, Note :- It may be assumed that 2/3 of the number are males and 1/3 are females., TABLE 14, , SANITATION REQUIREMENTS, , Sl. Fitments Assembly occupancy and, No, Multiplex complex,, Theatres, Auditorium, Art, Galleries,, Libraries,, Restaurants, Wedding halls,, Community halls, (1) (2), (3), 1 Water, 1 per 200 males or part, Closet, thereof and 1 per 100 females, or part thereof for the first, 1000 sq.meters of built up, area and 1 per 400 males or, part thereof and 1 per 200, females or part thereof for the, remaining area., , Assembly, , Assembly, , Assembly, , Bus Terminal, , Railway Station Air ports, , (4a), 4 for first 1000, persons and 1, for, every, subsequent, 1000 persons or, part thereof, , (4b), 5 for first 1000, persons and 1, for, every, subsequent, 1000 persons or, part thereof, , (4c), 5 for first 1000, persons and 1 for, every subsequent, 1000 persons or, part thereof, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 66
Page 77 :
67, , KERALA PANCHAYAT BUILDING RULES 2019, 2, , Urinals, , 3, , Wash, Basin, , 4, , Bath, , 1 per 50 persons or part, thereof for the first 1000, sq.meters of built up area and, 1 per 100 persons or part, thereof for the remaining, area., 1 for every 200 males and 1, for every 200 females for the, first 1000 sq.meters of built, up area and 1 per 400 males, and 1 per 400 females or part, thereof for the remainingarea., , Sl. Fitments Hotels, No, , 6 for first 1000, persons and 1, for, every, subsequent, 1000 persons or, part thereof, 4 wash basins, in each male, and, female, toilet stalls, , 6 for first 1000, persons and 1, for, every, subsequent, 1000 persons or, part thereof, 4 wash basins, in each male, and, female, toilet stalls, , 6 for first 1000, persons and 1 for, every subsequent, 1000 persons or, part thereof, 4 wash basins in, each male and, female, toilet, stalls, , Storage, Boarding, occupancy Institutions/Hostels/, Dormitories, , Other, educational, institutions, , Office/, mercantile, occupancies, , Industrial, occupancy, , (5), 1 per, 100, males, and 1, per 100, females, , (6), 1 per 50, males and, 1 per 25, females, , (8), 1 per every 40, boys and 1 per, every 25 girls, , (9), 1 for every, 25 males or, part thereof, and 1 for, every, 15, females or, part thereof, 1 for every, 25 persons, or, part, thereof, , (10), 1, per, every 25, males and, 1 per every, 15 females, , (7), 1 per every 10 boys, and 1 per every 8, girls, , 1, , Water, Closet, , 2, , Urinals, , 1 for, every, 25, persons, or part, thereof, , 1 per 100 1 per every 25 boys, males or, part, thereof, , 3, , Wash, Basin, , 1 for, every, 25, persons, or part, thereof, , 1 per every 10 boys, and 1 per every 10, girls, , 4, , Bath, , 1 per, 100, persons, , 1 per every 10 boys, and 1 per every 10, girls, , 1 per every 50, boys, , 1 per every, 25 persons, or, part, thereof, , 1 per every 40 Preferably, boys and 1 per one on each, every 40 girls, floor, , As, required, for, particular, trades or, occupancy, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 67
Page 78 :
68, , KERALA PANCHAYAT BUILDING RULES 2019, TABLE 15, SANITATION REQUIREMENTS FOR MEDICAL/HOSPITAL OCCUPANCY, with Hospitals, with, Sl.No Fitments Hospitals, Administration Building, indoor patients ward outdoor patients, For, males, and, females, (3), One for every 8 beds, or part thereof, , For, For, males, females, (4), (5), One for Two, for, every, every 100, 100, persons or, persons, part, or, part thereof, thereof, One in each water, closet. One water tap, with, draining, arrangement shall be, provided for every 50, persons or part thereof, in the vicinity of water, closets and urinals, , For, male, personnel, (6), One, for, every, 25, persons or, part thereof, , For female, personnel, (7), One for every, 15 persons or, part thereof, , (1), 1, , (2), Water, Closet, , 2, , Ablution, taps, , One in each water, closet plus one water, tap with draining, arrangement in, the vicinity of water, closets and urinals, for every 50 beds or, part thereof, , 3, , Wash, Basins, , 4, , Baths, with, shower, , Two up to 30 beds; One for every 100 One for every 25 persons or, add one for every persons or part thereof part thereof, additional 30 beds or, part thereof, One, bath, with, One on each floor, shower for every 8, beds or part thereof, , 5, , Bed pan, washing, sink, Cleaners, sink, Kitchen, sink and, dish, washers, (where, kitchen is, provided), Urinals, , 6, 7, , 8, , One in each water closet. One, water tap with draining, arrangement shall be provided, for every 50 persons or part, thereof in, the vicinity of water closets, and urinals, , One in each ward, One in each ward One, per, minimum, minimum, One in each ward, minimum, , floor One per floor minimum, , One for every 50 Nil up to 6 persons, 1 for 7-20, persons or part thereof persons, 2 for 21-45 persons, 3, for 46-70 persons, 4 for 71-100, persons From 101 to 200, persons add at the rate of 3%., For over 200 persons add at the, rate of 2.5%., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 68
Page 79 :
69, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that in the case of Information technology parks / technology parks sanitation, requirements shall be that of 75 % of the office occupancy., (2) The Minimum sanitation facilities to be provided in hazardous buildings shall be as, given below:, (a), , (b), (c), , (d), (e), , at the rate of one water closet for the first 50 males or part thereof and two water, closet for the first 50 females or part thereof and thereafter one water closet for, every additional 70 persons or part thereof, whether male or female;, at the rate of one urinal for every 100 males or part thereof ;, , at the rate of one drinking water fountain for every 100 person or part thereof;, at the rate of one washing facility for 50 persons or part thereof ; and, , In cases where the total number of workers does not exceed 5, at least one water, closet shall be provided., , (3) Segregated sanitation for Visitors in Public Buildings, (a), , In respect of the following new buildings, special segregated sanitation facilities, as separate block shal be provided within the plot, in a conspicuous location,, outside the main building block(s):, (i), (ii), , (iii), (iv), (b), , (c), , (v), , Civil stations, Panchayat offices, Taluk offices, village offices, Any other office in plots owned by Government or Panchayat as, decided by the Government or Panchayat respectively from time to, time;, Hospitals with total built-up area more than 1000 sq.metres;, Bus stations, railway stations, airports and public water transport, terminals., Automobile fuel filling stations, , Such sanitation facility shall be at l---east 10 percent of the sanitation, requirement stipulated in Tables 14 and 15 for water closets, urinals and, wash basins subject to a minimum of one WC, urinal and washbasin each for, male, one WC and washbasin each for female and one WC and washbasin, each for disabled persons. The minimum standards for WC and Washbasin, for disabled shall be as provided in rule 42., , It must be accessible to visitors and general public during the operational, hours of the building., , (4) As far as possible, low water consumption plumbing fixtures shall be provided in all, buildings., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 69
Page 80 :
70, , KERALA PANCHAYAT BUILDING RULES 2019, (5) In the case of Government owned Information Technology Parks, Government approved, Private Information Technology Parks, Government approved private Information, Technology buildings under Group E occupancy, additional sanitation facilities for, visitors need not be provided., , 35. Staircases and fire escape staircases.(1) Staircases.-, , (1) Any building having more than one floor shall be provided with a staircase unless, each such floor is independently accessible from ground., (2) The number and width of stair shall be determined with respect to the occupant, load as table 16 of these rules and maximum travel distance between two stairs, shall not be less than 60m., (3) For such stair:-, , (a) minimum width of stair shall be 120 centimeters,, (b) minimum width of tread shall be 30 centimeters,, (c), , maximum height of riser shall be 15 centimeters, , (d) minimum height of handrail shall be 90 centimeters, , (4) The minimum headroom in a passage under the landing of a staircase and under, the staircase shall be 2.2m., (5) Any building having more than three floors including basement floor(s) shall, have at least two staircases, one of which may be a fire escape staircase:, , (6) Escalators can be provided instead of staircases. The width of such escalators, shall not be less than one metre., , (2)Fire escape staircase:(1), , Fire escape staircase shall be provided for every building under:-, , (a) Residential occupancy exceeding three storeys above ground level;, , (b) Non-residential occupancies exceeding two storeys above ground level, , Note:-Fire escape staircase is one which is connected to public areas and/or common, areas on all floors and leads directly to exterior open space at ground, has at least, one side abutting external wall, this side being provided with openable glass or, break open glass or fully open and has landing areas accessible from the external, side to facilitate rescue operations during an emergency., (2) Width of fire escape staircase shall not be less than one metre, (3) Tread shall not be less than 25 centimetres, (4) Riser shall not exceed 19 centimetres and the number of risers shall not exceed, 16 per flight of stairs, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 70
Page 81 :
71, , KERALA PANCHAYAT BUILDING RULES 2019, (5) Height of handrail of a fire escape staircase shall not be less than 100, centimetres and not more than 120 centimetres., (6) The spacing between the balustrades should be less than 15 centimetres., (7) The use of spiral staircase shall be limited to buildings up to 10 metres in, height. Spiral staircase shall not be less than 150 centimetres in diameter and, shall be designed to give adequate head room., , (8) Fire escape stairs shall have straight flight for building exceeding 10 metres, height, , (9) Entrance to fire escape stair shall be separated and as far as possible remote, from other staircase(s) if any., (10) If the staircase provided for the building upto three storeys satisfies the, provisions of fire escape stair also, no separate fire escape stair is needed., , (3) Ramps.-, , Ramps, if provided as a substitute for stairways, shall be laid with a slope not, exceeding 1 in 10 and such ramp shall comply with all requirements of a stairway, and shall be surfaced with approved non-slippery materials., , 36. Travel distance to emergency exit.- (1) Every building meant for human occupancy, shall be provided with emergency exit sufficient to facilitate safe escape of occupants in, case of fire or other emergency., (2) Emergency exits shall be located in such a way that the travel distance on each floor, shall not exceed 30 metres for every occupant., (3) Emergency exists may be either horizontal or vertical., , (4) Emergency exits in the case of ground floor may be a doorway, corridor or passage, to an internal staircase or external staircase, ramps to the street or to the roof of a, building, which may be horizontal exits leading to the ground or adjoining building, at the same level. In the case of upper or lower floors, emergency exits may be a, staircase leading to the ground., Provided that lifts and escalators shall not be considered as emergency exits., , 37. Exit Width.- (1) The unit of exit width used to measure the capacity of any exit shall, be 50 centimetres, a clear width of 25 centimetres shall be counted as an additional half, unit and clear width less than 25 centimetres shall not be counted for exit width., (2) Occupants per unit exit width shall be as in Table 16., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 71
Page 82 :
72, , KERALA PANCHAYAT BUILDING RULES 2019, TABLE 16, OCCUPANTS PER UNIT EXIT WIDTH, Group of occupancy, , Sl. No., (1), 1, 2, , (2), Group A1 Residential, Group A2 Lodging Houses, Special Residential, Group B Educational, Group C Medical/Hospital, Group D Assembly, Group E Office, GroupFMercantile, (Commercial), Group G1 Industrial-I, Group G2 Industrial-II, Group H Storage (including, Warehousing), Group I Hazardous, Group J Multiplex complex, , 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, , No. of Occupants per, unit exit width of, Stairway, , No. of Occupants per, unit exit width of, Doors, , 25, 25, 60, 50, 50, , 75, 75, 90, 75, 75, , 50, 50, 50, , 75, 75, 75, , 25, 50, , 40, 75, , (3), 25, & 50, , (4), 75, 75, , (3.) For determining the exit width required, the number of persons in any floor or the, occupant load shall be based on the actual number of occupants but in no case less than that, specified in Table 17., TABLE 17, OCCUPANT LOAD, Sl. No., (1), 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, , Group of occupancy, , Occupant Load (built up, area in square metres per, person), (3), 12.5, Special 4.0, , (2), Group A1 Residential, Group A2 Lodging houses &, Residential, Group B Educational, Group C Medical/Hospital, Group D Assembly, Group E Office, Group F Mercantile (Commercial), Group G1 Industrial-I, Group G2 Industrial-II, Group H Storage (including Warehousing), Group I Hazardous, Group J Multiplex complex, , 4.0, 15.0, 1.5, 1.5, 4.5, 10.0, 10.0, 30.0, 10.0, 4.5, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 72
Page 83 :
73, , KERALA PANCHAYAT BUILDING RULES 2019, (4), (5), , Exits shall be either horizontal or vertical type., , An exit may be a doorway corridor or passageway to an internal staircase or an external, staircase (upstairs, downstairs or both), or a ramp which has access to the street or to, the roof of a building;, , Provided that lifts and escalators shall not be considered as exits., , (6) For determining the exit width of staircases the width of one flight of stair is considered., , 38., , Doorways.- (1) Every exit doorway shall open into an enclosed stairway or a, horizontal exit or a corridor or passageway providing continuous and protected means, of egress., (2) No exit doorway shall be less than 75 centimeters in the case of residential and, 1.2metres in the case of all other occupancies., , 39., , 40., , (3) Revolving door shall not be provided as a means of fire exit., , Corridor, verandahs and passageways.- The clear width of any corridor, verandah or, passageway in any building shall be not less than 1.0 metre at any point. The width of, passages giving access to the staircase shall not at any point be less than the width of, the stair., Lift /Escalator - (1) Any building exceeding three storeys in the case of group CHospital/medical occupancy and four storeys in the case of other occupancies shall, have at least one lift., , Provided that additional lift shall be provided at the rate of one lift for every, 2500 sq. metres of the total built up area or part thereof (except parking area provided, inside the building) in excess of the first 4000 square metres, or by adopting the, provisions in the National Building Code for calculating the number of lifts/ escalator,, in which case, the respective registered engineer, architect etc. shall furnish certificate,, design calculation and specifications all duly signed, along with the application for, building permit. The certificate shall be to the effect that the lifts/ escalator provided, conform to the provisions of the National Building Code., (2), (3), , (4), , The planning, design and installation of lifts / escalator shall be in accordance, with Part 8, Volume 2, Section 5 in National Building Code of India, 2016., , Whenever more than one lift is required as per sub-rule (1) or byelaws made, under the Act, at least one lift shall be a higher capacity lift that can carry a, stretcher., , In the case of high rise apartment building having more than 16 dwelling units, at, least one lift capable of carrying a stretcher shall be provided:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 73
Page 84 :
74, , KERALA PANCHAYAT BUILDING RULES 2019, 41., , Lighting and Ventilation.- (1) Every habitable room shall be furnished with, sufficient number of openings such as windows and ventilators affording effectual, means of admission of light and air by direct communication with the external air or, shall be sufficiently lighted and ventilated by artificial means., , (2) No portion of a room shall be assumed to be lighted if it is more than 7.5 metres, away from the opening assumed for lighting that portion unless it is artificially, lighted., , (3) Windows and ventilators which open into a verandah shall be deemed to, communicate with the external air, if such verandah is not more than 3 metres, wide and open throughout its entire length into an open space open to the sky, the, width of such open space being not less than 3.0 metres. Trellising, mesh, grill or, net may, however, be provided on the open side of the verandah;, (4) Every kitchen shall be ventilated according to the standards stipulated for habitable, rooms and shall have suitable flue for the escape of smoke and heated air unless it, is provided with an approved form of smokeless installation., (5) Every bathroom or latrine shall be provided with sufficient light and ventilation.-, , (6) Every bathroom or latrine shall have at least one of its walls abutting on an open, space or open verandah or an air shaft if not centrally air conditioned; the size of, air shaft shall not be less than that specified in Table 18., TABLE 18, SIZE OF AIR SHAFT, Sl. No., , No. of Storeys, , (1), 1, 2, 3, 4, , (2), Upto 3, Upto 6, Upto 10, Above 10, , 42., , Area of the airshaft, in Square metre, (3), 1.08, 2.4, 3.0, 5.0, , Minimum width of, Airshaft in metre, (4), 0.9, 1.2, 1.5, 2.0, , (7) All buildings coming under the purview of sub rule (5) of Rule5 shall also follow, the lighting and ventilation standards mentioned in the KSECBC, , Provisions for Differently-abled, Elderly and Children:- All buildings under, occupancy groups A2, B,C,D, E,F and J which have access to the public and all, apartment buildings/residential flats under occupancy group A1 shall be provided with, the following facilities for the differently-abled, elderly and children:, (1) Every such building shall have easy access to the main entrance through a ramp., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 74
Page 85 :
75, , KERALA PANCHAYAT BUILDING RULES 2019, (2) Every public building exceeding 1000 sq. metres and residential flats exceeding, 2500 sq. metres built-up area shall have lift or separate approach through a ramp, (intended for the differently-abled and elderly) to each floor. The minimum cage, dimensions of such lift shall be as follows:, (i) Clear internal width 110 cm, (ii) Clear internal depth 200 cm, (iii) Entrance door width 90 cm, , (3) The maximum gradient of any ramp approach intended for the differently-abled,, elderly and children shall not exceed 1 in 12 and shall be finished with nonslippery material. The minimum width of ramp shall be 120 cm. and provided with, handrails of 80 cm height on both sides. Minimum gap from the adjacent wall to, the hand rail shall be 50mm. The slope of all such ramps shall be constant within a, building. Entrance landing shall be provided adjacent to ramp with the minimum, dimension 120 cm x 150 cm., (4) Toilets:-, , A minimum of one special water closet shall be provided for the use of the, differently-abled and elderly with essential provision of a wash basin at an easily, accessible location with proper signages:, Provided that in the case of such special toilets:, (a), , (b), (c), , (d), (e), (f), , (g), , These shall be provided at the ground floor for A1, A2,B,C,D,E, F & J, occupancies and at every floor in multiples of three for A2,B,C,D,E, F& J, occupancies., Minimum size of toilet shall be 1.50 m x 1.75 m., , Minimum clear opening of the door shall be 90 cm. wide, the door shall, swing out, or be sliding or folding type., , Suitable arrangements of vertical/horizontal handrails with 5cm. clearance, from the wall shall be provided in the toilet., The water closet seat shall be 50 cm. above from the floor level:, , At least one sink in each floor shall have a knee room of 70cm. high under, the sink; and, Locks of such toilet doors shall be of a type that can be opened from outside, in case of emergency., , (5) Parking facilities, , (a) 3% of the required parking subject to a minimum of one car space, shall be, provided near the entrance, exclusively for use of the differently-abled with, maximum travel distance of 30 metres, from the building entrance., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 75
Page 86 :
76, , KERALA PANCHAYAT BUILDING RULES 2019, (b) The width of such parking bay shall be at least 3.6 metres., , (6) Walks and paths:, , (a) Walks shall be smooth with hard level surface suitable for walking and, wheeling. Avoid grates and manholes in walks. If grates cannot be avoided,, then bearing bar shall be perpendicular to the travel path and opening between, bars shall not be greater than 12mm in width., (b) The walkway shall not cross vehicular traffic., , (7) In Group A2 Lodging Houses & Special Residential, one room for every 25 rooms, or part thereof shall be set apart for the differently-abled., (8) Other Special Treatments, , (a) All obstructions and projections up to a minimum of 2.1 metre height from the, finished floor level shall be avoided., (b) Recoil doors shall be avoided, wherever there is access to the general public;, , (c) Minimum & clear opening of the entrance door shall be 90 cm and it shall not, be provided with a step that obstructs the passage of a wheel chair user., (d) Appropriate signages shall be provided at salient locations for facilitating the, differently-abled., , 43.Other provisions for Apartment buildings under Group A1 Residential occupancy(1)Any residential apartment having more than 12 dwelling units in a single plot or single, building shall be provided with a recreational space of suitable size but minimum, dimension of such recreational open space shall be more than 1.2 m., (2) The recreational open space as per sub rule (1) shall not be less than 6% of the total, , built-up area of all floors taken together. A minimum 35% of such recreational space, shall be provided outside the building on the ground itself. Remaining recreational, space may be provided either inside a building or outside or both. The recreational, space, if provided outside a building on the ground, shall be exclusive of parking areas,, driveways and the like. Recreational open space shall be given in ground level above, utility areas such as underground sump, sewage treatment plants only after providing, adequate safety measures. Recreational space shall not be provided above manholes. If, recreational space is partly provided on any open terrace, the recreational space so, provided shall not be more than 25% of the open terrace area. Such space shall be, enclosed all around either by walls or parapet walls made of stable materials to a height, of not less than 150 centimetres with grill mesh of size not more than 10 centimeters x, 10 centimetres over it up to further height of 150 centimeters. Such recreational space, in open terrace shall be provided with safety measures including exits as per these rules., Note- (1) Spaces like swimming pool, recreation hall or health club shall also be, considered as recreation space for this purpose., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 76
Page 87 :
77, , KERALA PANCHAYAT BUILDING RULES 2019, (2) The recreation space may be provided as a single unit or as different units., (3) The recreational space(s) so provided shall be easily and safely accessible to, differently-abled persons including children with special needs., , 44. Other provisions for Group D Assembly Occupancy buildings- (1), room in Assembly occupancy buildings shall be minimum 4 metres;, , The, , height, , of, , Provided that in the case of air conditioned auditoriums/halls it shall be minimum, 3 metres;, , (2), , The clear head room beneath and above the mezzanine or balcony shall be not less, than 3 metres., , Provided that such headroom shall not be less than 2.4 metres in air conditioned, rooms., , (3), , The height of store room, toilets, lumber, and cellar rooms shall not be less than 2.4, metres, , (4), , Balconies or galleries or mezzanines shall be restricted to 25 per cent of the total, built-up area of assembly hall area., , (5), , The maximum slope of the balcony or gallery or mezzanine shall not exceed 35, degrees., , (6), , The Standard of ventilation in assembly occupancy buildings shall be 28 cu.m fresh, air per seat per hour., , (7), , In the case of Cinema theatres, the location, size and building construction shall, conform to the Provisions in the Kerala Cinema Regulations, 1988 as amended from, time to time and the IS : 4878-1968, Byelaws for construction of Cinema Buildings., , (8), , (i), , (ii), (iii), , In the case of alteration to existing authorised cinema hall(s)/theatre(s) into multiple, screens without increasing the total seating capacity, and if such internal alteration, include only structures relating to fixing of cinema screen(s) and interior, partitioning, Secretary shall permit such internal changes of the building, subject to, the following conditions:-, , in the case of addition, alteration, reconstruction or change in occupancy of the, existing cinema theatres whether having existing valid license or had a valid, license as per Kerala Cinemas (Regulation) Act, 1958 (32 of 1958), building, permit shall be issued only if a cinema theatre having 1/3rd seating capacity of, the existing theatre, is also proposed/retained., the existing coverage, total built-up area on all floors, total seating capacity and, height of building shall not be exceeded;, the available off-street parking spaces and yards or open spaces or setbacks of, existing authorised building(s) shall not be reduced;, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 77
Page 88 :
78, , KERALA PANCHAYAT BUILDING RULES 2019, (iv), , provisions contained in rule 81(9) and 81(10) of these rules shall apply, irrespective of whether the building is a high-rise building or not:, , Provided that works as specified in item (i) to (iv) of rule8 for which permit is not, necessary may also be carried out along with such alteration;, Provided further that the provisions in this sub-rule is applicable to only those, existing authorised cinema halls/buildings which are to be used exclusively for, showing films., , 45.Other provisions regarding Group G1 and G2 industrial occupancy buildings - (1), Location of any industry shall conform to the provisions contained in the Kerala Factories, Rules, 1957 or any other Central or State Act or Rules or Regulations in respect of, industrial location and licensing in force., (2) In areas falling under the purview of the Kerala Industrial Single Window Clearance, Boards and Industrial Township Area Development Act, 1999 (5 of 2000), provisions, as applicable under that Act shall be followed., , (3) All work rooms in buildings under industrial occupancy shall be provided with a builtup area computed at a rate, not less than 4.2 sq. metres. per person employed in such, rooms, exclusive of built-up area occupied by the machinery and breathing space of 15, cubic metres per worker:, Provided that the areas of any work room shall be not less than 9.5 Sq. metres., , (4) The minimum height of work room shall depend upon the type of industry, the, noxious gases which might be produced or the heat generated due to the process, the, specification of room construction, the number of workers employed in any work area, and the comfort conditions available through installation of mechanical ventilation or, air conditioning system :, Provided that the height of any work room shall not be less than 3.6 metres measured, from the floor level to the lowest point in the ceiling., , (5) Height of office, laboratory, entrance hall, canteen, cloakroom etc. shall not be less, than 3 metres., (6) In the case of store rooms, and toilets the height shall not be less than 2.4 metres., , 46.Other provisions regarding Group H Storage occupancy buildings- Every building or part, thereof, designed or intended for the storage of food stuffs shall conform to the, requirements specified below:, (1) every building unless supported on pillars shall have continuous foundation walls, extending from at least 60 centimetres below ground level to at least 15 centimetres, above ground level or shall have a continuous floor of masonry or reinforced concrete, or other quality rat- proof-material., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 78
Page 89 :
79, , KERALA PANCHAYAT BUILDING RULES 2019, (2) all openings in foundations or floors, windows and drains and all junctions between, foundations and walls of the building shall be effectively rat-proofed; windows and, doors shall be securely covered with rat-proof screening or grillage or shall be tightly, closed with metal sheeting, concrete or other equally rat-proof-material., , 47.Other provisions regarding Fuel filling stations under Group I Hazardous occupancy - (1), The location and or construction of fuel tank and vent-pipe shall be governed by the, provisions of the Petroleum Rules, 2002., (2) A clear space of not less than 7.5 metres shall be provided all around the retail, dispensing units of fuel filling station., , Provided that in the case of fuel pumping station intended to fuel boats and the like, the, retail dispensing unit shall be installed at a distance of not less than 3 metres from the, boundary of waterfront., , (3) The kiosk or sales office shall have a minimum open space of 1metre from the plot, boundaries other than that abutting the street., , (4) In the case of canopies with sheet roof attached to automobile fuel filling stations, a, setback of not less than 3metres from road boundaries abutting the plot and not less, than one metre from other plot boundaries shall be provided. Such canopy shall not be, counted for calculation of coverage and F.S.I., , 48.Certain Buildings exempted.- Single family residential buildings, other than apartments, under Group A1 residential occupancy shall be exempted from the provisions in this chapter., CHAPTER VI, , SPECIAL PROVISIONS FOR HUTS AND CERTAIN OTHER CONSTRUCTIONS,, TRIBAL COLONIES AND BUILDINGS IN SMALL PLOTS, 49.1 Special provisions for huts and certain other constructions:- (1.) Provisions in this rule, shall apply to the following constructions or reconstructions or additions or alterations and, development or redevelopment of land pertaining to;, (i) Huts; mentioned in Rule 8 item (xi), (ii) Single family residential buildings in Category –II Village Panchayats under, Group A1 – Residential occupancy with total built-up area on all floors upto 100 sq., metres (including existing and proposed within the plot) and number of storeys, limited to two., All statutory acts and laws will be applicable to the construction of huts., (2) Permit not necessary: - For buildings as stipulated in sub rule (1) of rule 49.1, permit, as per these rules is not necessary., (3) Provisions regarding distance from road, etc: (1), , For huts the following provisions shall apply:-, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 79
Page 90 :
80, , KERALA PANCHAYAT BUILDING RULES 2019, , (i) The minimum distance between the plot boundary abutting any street other than, National Highway, State Highways, or District roads or other roads notified by the, Panchayat and the hut shall be 1.0 metre., (ii) All sides including the front and rear shall have minimum 60 centimetres distance, from all the boundaries other than that abutting a road., , (2)For single family residential buildings in Category –II Village Panchayats under Group, A1 – Residential occupancy with total built-up area on all floors upto 100 sq. metres, (including existing and proposed within the plot) and number of storeys limited to two, the following provisions shall apply:-, , (i) The minimum distance between the plot boundary abutting any street other than, National Highway, State Highways, or District roads or other roads notified by the, Panchayat and the building shall be 1.5 metre., (ii) All sides including the front and rear shall have minimum 90 centimetres distance, from all the boundaries other than that abutting a road., , Provided that, any yard other than that abutting a street can be reduced upto a width of, 60 centimetres and can even abut the boundary with the written consent of the owner of, the land on that side, , Provided further that no openings shall be provided on sides abutting the plot boundary, and only ventilators (above a height of 2.20 metres above the floor level) shall be, provided if the width of yard is less than 60 centimetres:, Provided further that, no construction or hanging of any sort shall project outside the, boundaries of the site:, The projections like cornice roof, sun shade and weather shade shall be so limited that, the width of the remaining open space shall not be less than 30 centimetres:, , (4). If the site is within a distance of 10 metres from any property maintained by Defence, establishment and/or within 30 metres from the railway boundary and/or within any, Security Zone, no work shall be commenced at site, until letter of intimation of the, Secretary with regard to objections if any furnished by the authority or officer concerned, as per sub rule 4 of rule 5 as the case may be, are received by the owner. In such cases,, the Secretary shall carry out actions for obtaining objections if any from the respective, officer/authority and the same shall be intimated to the owner in writing immediately., 49. 2. Special provisions for Tribal colonies.- (1) When the Panchayat in which these rules are, extended comprises Tribal Area Declared/notified by Government, the provisions in this, chapter need only be made applicable to those constructions/developments intended for, Tribal people or made by Tribal people, in Tribal areas., (2) In the case of construction/developments by authorised agencies for the welfare of Tribal, people; the Engineer or Architect in charge of the project/scheme shall prepare layout and, designs suitable for the area and life style of the Tribals, in consultation with their, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 80
Page 91 :
81, , KERALA PANCHAYAT BUILDING RULES 2019, representatives including the "Mooppan" of the area; and get them approved by the, Panchayat., i., , The minimum distance between the plot boundary abutting any street other than, , National Highways, State Highways, District roads and other roads notified by the, , Panchayat and the building other than compound wall or fence or out door display, (ii), , structure shall be 1.0 metres;, , Number of floors shall be limited to two & a stair room;, , (iii) The minimum distance between buildings shall not be less than 1.50 metres;, , (iv) Minimum front open space of 1.50 metres shall be provided exclusively for each, , unit;, , (v) A toilet shall be provided for each unit; with necessary leach pit or septic tank,, which may be common., , 50., , (3) In the case of construction/developments other than huts made by Tribal people in their, land inside or outside a cluster of houses/settlement; the Panchayat may provide, necessary assistance and guide lines so as to conform to the guide lines in sub rule 2 of, rule 49.2, and also give necessary technical and infrastructural support as far as, possible; and number the houses., , Special provisions for construction in small plots.- (1) Applicability: The provisions in the, Kerala Panchayat Building rules, 2019 shall apply to construction of building under Group, A1-Residential and/or Group F- Commercial occupancy, in plots not exceeding 125, sq.metres of area subject to modifications in this chapter:, , Provided that permit shall not be granted under this rule to one and the same person, or with his consent to another person, for constructing different buildings, whether, separately or abutting each other, in plots formed by division of one or more plots, he, remaining as owner of more than one such divided plots or if that person has another plot, abutting the proposed plot, , (2), , Number of floors to be limited.-The number of floors allowed shall be 3 floors, and stair-room with maximum height of building restricted to 10 metres excluding, stairroom., , (3), , Certain provisions not to apply.- Provisions regarding F.S.I., coverage, access, width, height restriction with regard to width of road and the yard abutting the road,, off-street parking, dimension with regard to building parts and light and ventilation, shall not apply to buildings under this Chapter., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 81
Page 92 :
82, , KERALA PANCHAYAT BUILDING RULES 2019, CHAPTER VII, ROW BUILDINGS, 51., , 1, 2, , 3, , 4, 5, 6, , 7, , 8, , Special provisions for row buildings, , Applicability: The provisions in the Kerala Panchayat Building Rules, 2019 shall apply to, construction of row buildings subject to modifications in this chapter:, , Row buildings to be allowed on declared streets.- The Secretary shall permit the, construction or reconstruction of row buildings only on the sides or part of a side or sides, of any street, where the Panchayat has by declaration published, decided to allow row, buildings., Number of units that can be permitted.-The number of dwelling units in a row of, buildings shall not exceed ten., , Note :- A row building with separate entry and exit and separated by common wall from, other row buildings abutting it shall be deemed to be one unit for this purpose., Plot area.- The area of plot for one unit shall not exceed 85 sq. metres., , Maximum floors.- The maximum number of floors permitted shall be two and a staircase, room., , Certain provisions not to apply.- Provisions regarding F.S.I., Coverage, access width,, height restriction with regard to width of road and the yard abutting the road, dimension of, building parts, light and ventilation and off street parking contained in these rules shall not, be applicable to row buildings., Submission of applications etc.-, , Application for permit and other documents required as per these rules may be submitted, either jointly or individually., Reconstruction, etc. of existing row buildings.-, , Notwithstanding anything contained in these rules, in the case of existing row buildings,, under Group A1 – Residential occupancy, reconstruction, repair, alternation or addition,, both horizontal and vertical shall be permitted irrespective of whether it is on the side of a, street where row buildings are permitted or not, and irrespective of the plot area, and, setbacks provided. In such case, the number of floors shall be limited to two., CHAPTER VIII, BUILDING CONSTRUCTION UNDER APPROVED SCHEMES, , 52.Provision for construction under approved Schemes.- Provisions in this chapter shall, apply to construction or reconstruction or addition or alteration of any building in, individual plots under any Government approved Schemes for economically weaker, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 82
Page 93 :
83, , KERALA PANCHAYAT BUILDING RULES 2019, section and financed or built by Government, Panchayat, Housing Board, Scheduled, Castes and Scheduled Tribes Development Corporation, Fishermen Welfare Corporation,, Matsyafed, Harijan Welfare Department, Social Welfare Department or any Government, Department, Quasi Government Agency, or Housing Co-operative Societies. The, provisions in this Chapter shall also apply to buildings financed or built by any Panchayat, at any level to its beneficiaries., , 53. Area and floor restrictions.(1), , Total floor area of each dwelling unit shall not exceed 66 sq. metres., , (2), , Number of floors shall be limited to two and a staircase room., , 54. Setback provisions.(1), , The minimum distance between the plot boundary abutting any street other than, National Highways, State Highways, PWD roads, district roads, other roads notified by, Panchayat, other roads with width 5m and above and the building, other than a, compound wall or fence or outdoor display structure, shall be minimum 1.50 metres., , (2), , Front yard shall have minimum 1.00 metre width., , (3), , In the case of individual developed plots requiring no lay out approval from the District, Town Planner, there shall be average 60 centimetres open space on the sides and the, rear:, Provided that no door shall be allowed on any portion, if that portion does not have, minimum 1 metre open yard., , (4), , In the case of buildings requiring layout approval of District Town Planner, the side, yards and rear yard shall be provided as shown in the building layout:, Provided that no portion of the building shall encroach, project or overhang beyond the, plot boundaries., , 55. Certain provisions not to apply.- Provisions regarding F.S.I., coverage, off-street parking, space, access width, height restriction with regard to width of road and the yard abutting, the road, dimensions with regard to building parts, light and ventilation shall not apply to, building under this chapter., , 56. Application for permit and its disposal.- (1), Where, the, construction, or, reconstruction or addition or alteration is proposed to be done by individuals separately, an, application in white paper, typed, or written in ink and affixed with necessary court fee, stamp shall be submitted by the individual concerned to the Secretary, along with a site, plan showing proposed building footprint and document to prove his ownership. The, number of floors and the area in each floor shall be specified in the application., (2), , Secretary shall, if convinced of the boundaries and bonafides of the ownership and, that the building is in accordance with the rules in this Chapter, issue permit., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 83
Page 94 :
84, , KERALA PANCHAYAT BUILDING RULES 2019, (3), , There shall be no application fee in the case of individual application and the permit, fee in the case of individual application shall be as shown in Schedule-II., , (4), , Where the construction or reconstruction or addition or alteration is proposed to be, done by the Department, Corporation, Board, Agency, Local Self Goverment, Institution or Society themselves, layout for sub-division shall be obtained from the, Secretary and no building permit is necessary., CHAPTER IX, , SPECIAL PROVISIONS FOR LARGE-SCALE DEVELOPMENT, PROJECTS APPROVED BY GOVERNMENT, 57., , 58., , Applicability of the Provisions. - Provisions in this chapter shall apply only to large scale, development projects, expansion projects approved by Government, by order, and for, availing benefit of higher Floor Space Index, the projects shall have an area not less than 1, hectares, an investment exceeding Rs.100 crores including land value and which shall, provide for employment, for not less than 500 persons as per commissioning of the, project., Constitution and functioning of the committee. - (1) The Government may accord, sanction for the project mentioned above, based on the recommendation of a committee, to, be constituted by the government for the purpose, consisting of the following members:, (i), , The Principal Secretary/Secretary to Government,, Local Self Government Department, , - Chairperson, , (ii), , The Director, Department of Urban Affairs, , - Member, , (iii) The Chief Town Planner, Department of, Town and Country Planning, (iv) The District Officer of the Department of, Town and Country Planning having jurisdiction, over the district concerned, (v), , Secretary(s)of the Local Self Government, Institution(s) concerned, , - Convenor, , - Member, - Member(s), , (2) The developer shall submit the project report, detailing the demand, feasibility and, Environmental Impact Assessment aspects of the project, together with the approval,, if necessary, obtained from the Ministry of Environment and Forests, Government of, India to the Convener of the committee and the Convener shall make all arrangements, for convening meeting of the committee at the earliest and the committee shall, consider and dispose of the project report within a period of one month from the date, of receipt of the same., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 84
Page 95 :
85, , KERALA PANCHAYAT BUILDING RULES 2019, (3) The Convener shall fix the venue, date and time of the meeting in consultation with, Chairperson and shall be responsible for safe custody of records and communications, thereof., (4) The meeting shall be presided over by the Chairperson or in his absence by a member, to be authorised by him., (5) The quorum of the meeting shall be majority of the total number of members of the, committee for the project., (6) The developer shall also produce before the committee, all required clearances from, the State and Central Government agencies concerned., , 59. Provision for supporting infrastructure.- (1), Adequate provision shall be made for, supporting infrastructure such as water supply, sewage, solid waste management, power, supply etc., (2), , Separate sewage treatment plant and systems for solid waste management shall be, provided and maintained by the developer at his cost., , 60. Memorandum of Understanding.- There shall be Memorandum of Understanding between, the developer and the Secretary of the Local Self Government Institution concerned with, adequate provisions for bringing the project into effect., 61. Other provisions.(1)., , (2)., (3)., , (4)., , The F.S.I. permissible for the project:- The F.S.I permissible for such projects, shall be 1.25 times the maximum value stipulated in column (6) & (8) of Table 6, under rule 27 (2) and in conformity with the Notes there under subject to a, maximum of 6 and the fee for the additional F.S.I. shall be as stipulated in column, (8)., Minimum width of access:- The minimum width of access shall be 12 metres., , Ceiling for Residential use:- Area for residential uses, if any, included in the, projects shall not exceed 40% of the land area of the project and shall be incidental, to the main use(s)., Period for completion:- The project shall be completed within a period of five, years, if not specified otherwise., CHAPTER X, , CONSTRUCTION IN PLOTS PART OF WHICH HAVE BEEN SURRENDERED FREE, OF COST FOR ROAD DEVELOPMENT, 62. Provisions to apply as modified for constructions in certain plots.- (1) In the case of, buildings newly proposed or alteration or addition proposed on existing buildings in plots, left after part of the same plot has been surrendered free of cost to the Panchayat,, Development Authority, or Government Department or Quasi-Government organization for, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 85
Page 96 :
86, , KERALA PANCHAYAT BUILDING RULES 2019, new road formation or road widening or junction improvement or formation or development, of any facility relating to road structure, other provisions in these rules shall apply subject to, the modifications in this chapter:, Provided that the applicants seeking benefit under this chapter shall apply in writing to, the Secretary in the form in Appendix A2:, Provided further that the provisions under this chapter shall not apply to the road, envisaged in any layout as per these rules:, , Provided also that the benefit under the provisions in this chapter shall not be allowed, to the constructions in such plots, if the land is not surrendered for the implementation, of the scheme in total:, , Provided also that such road formation or road widening or junction improvement or, formation or development of facility relating to road structure shall form part of the, annual plan or five year plan of the implementing agency concerned or shall have a, budgetary allocation and shall form part of and conform to any Master Plan / Detailed, Town Planning Scheme / Interim Development Order in force under the Kerala Town, and Country Planning Act, 2016 (9 of 2016) , if any such plan / scheme/ order exists:, , Provided also that any deviation from the proposals of a Master Plan / Detailed Town, Planning Scheme / Interim Development Order in force under the Kerala Town and, Country Planning Act, 2016 (9 of 2016), in the new road formation or road widening or, junction improvement or formation or development of any facility relating to road, structure, shall be carried out only affecting variation or revision, as the case may be, of, such plan / scheme / order:, , Provided also that in the case of roads which have no widening proposals as per any, Master Plan / Detailed Town Planning Scheme / Interim Development Order in force, under the Kerala Town and Country Planning Act, 2016 (9 of 2016), or which falls in, areas which are not covered by any such plan / scheme / order, it shall be a project, proposed or taken up, with the prior approval of the Local Self Government Department, in consultation with the Chief Town Planner of the state:, (i), , by the local self-government institutions or Development Authority, by resolution;or, , (ii) Sanctioned or undertaken by a Government Department, Quasi- Government, Organization or institution; or, , (iii), , (2), , By registered Residents Association or a Social Welfare Organisation., , Provided also that the surrendered land shall not be used for purposes other than that, envisaged in the scheme., , The surrendering of the land shall be made as per the relinquishing procedure laid out, in the Kerala Land Relinquishment Rules, 1958 and the land shall be demarcated and, taken into possession by the authority concerned. The existing compound wall or, fencing or any structure within the land so surrendered shall be demolished by the, owner at his risk and cost and the new boundary shall be demarcated suitably by, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 86
Page 97 :
87, , KERALA PANCHAYAT BUILDING RULES 2019, , (3), , permanent demarcating structures. The building permit shall be issued only after, completing the above procedure., , The Government may, either suomotu or at the request of the Panchayat concerned,, formulate road widening scheme by free surrender of land with such conditions as it, deems fit for the success of the scheme it shall have overriding effect over other, provisions of these Rules., , 63. Usage of Plot.-The usage of plot proposed for the development or redevelopment of land or, construction of any building shall be governed by the provisions contained in the Master, Plan/Detailed Town Planning Scheme / Interim Development Order in force under the Kerala, Kerala Town and Country Planning Act, 2016 (9 of 2016), for the area., 64. Other provisions, (1) Coverage and Floor Space Index.-, , (a) Maximum coverage permissible by the committee constituted under rule 65 shall, not exceed 80 per cent for residential, special residential, mercantile or, commercial, small industrial and storage occupancy; 60 per cent for assembly,, office and industrial occupancy, 50 per cent for educational, medical or hospital, and 40 percent for hazardous occupancy under Group I., (b) The maximum built-up area permissible based on the F.S.I. values for various, occupancies shall be calculated as follows., , Built-up area based on F.S.I. permissible as per column (5) or (7), as applicable, of, table 6 in rule 27 for the extent of the plot prior to surrendering of the land + an, incentive built-up area of twice the F.S.I. permissible as per column (5) or (7), as, applicable, of Table 6 in rule 27 for the extent of land surrendered free of cost., , Provided that the maximum F.S.I. permissible calculated in the above manner shall, not exceed the F.S.I. as per column (6) or (8), as applicable, of Table 6 for the entire, land., Provided further that F.S.I. of column (6) or (8) as applicable of Table 6 in rule 27, for the entire land shall be permitted on payment of additional fee at the rate, specified in Table 6, for the difference in area if any., , (2) Set back, height, etc.-, , (1) For buildings up to 10 m under various occupancies, the mandatory open, space/setback from the proposed road boundary to the building shall be reduced by, the breadth of the land so surrendered from that side, subject to the minimum of, 3.0m from the boundary of the proposed road:, Provided that, in the case of plots up to 125sq.metres of area left after surrendering, the land for road schemes other than National Highways and State Highways, the, committee constituted under rule 65 may, considering the width of the land,, surrendered and left behind shall permit reductions in the said distance to such, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 87
Page 98 :
88, , KERALA PANCHAYAT BUILDING RULES 2019, extent that, after such reduction, there shall be a minimum of 1.50metre distance, from the abutting new road boundary:, , Provided further that the setbacks on all other sides shall be reduced in proportion, to the percentage of the land surrendered subject to a maximum reduction of, 50% of the mandatory open space required for the respective occupancies for, buildings up to 10m., Provided also that in the case of high rise buildings safety provisions for high rise, buildings as provided in Chapter XVII of these rules shall apply., , (2) In addition to the minimum front, rear and side open spaces required as per(1)above, for height up to 10 metres, proportionate increase in such minimum open spaces at, the rate of 0.5 metres for every 3 metres height exceeding 10 metres shall be, provided., , (3) Not withstanding anything contained in these rules, in the case of buildings, part of, which has been demolished for the purposes specified in rule 62,construction or, reconstruction of wall with or without door(s) or shutter(s) shall be permitted on, the side abutting the road, without structural alteration:, (4), , Provided that the door shutter shall not open outward., , Building lines specified in Master Plan / Detailed Town Planning Scheme / Interim, Development Order in force under the Kerala Town and Country Planning Act,, 2016 (9 of 2016), other than special building lines prescribed considering the, urban design or heritage aspects, and general provisions regarding restriction on, height with respect to width of street and front set back shall not apply to, the constructions under this chapter., , (3) Parking.-, , Parking requirements shall be reduced in proportion to the percentage of land, surrendered to the extent that after such deductions a minimum of 75% of the parking, required as per these rules shall be provided., , 65. Constitution of Special Committees.- (1) The Government may, on receipt of a request, to that effect from any Panchayat or suomotu, if found necessary, by order, constitute a, Special Committee, for the purposes of any or all Panchayats, to consider and decide on the, application for building permits that may be submitted under the provisions of this Chapter., (2) The Special Committee shall consist of the following members, namely:(i), , (ii), , President of the Panchayat, who shall be the Chairperson of the Committee., Chairperson of the Development Authority, if any, constituted for the area, , (iii) Senior Town Planner / Town Planner of the District office of the Town and, Country Planning Department or an officer not below the rank of a Deputy Town, Planner authorized., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 88
Page 99 :
89, , KERALA PANCHAYAT BUILDING RULES 2019, , (iv) Executive Engineer (Roads), Public Works Department having jurisdiction in the, area or an Officer not below the rank of an Assistant Executive Engineer, authorized., (v), , Executive Engineer(Buildings), Public Works Department having jurisdiction in, the area or an Officer not below the rank of Assistant Executive Engineer, authorized., , (vi) Town Planner of the development authority, if any, constituted for the area or an, Officer not below the rank of a Deputy Town Planner authorized., (vii) Secretary of the Panchayat concerned, shall be the convener of the Committee., , (viii) One or two representatives of the Department, Authority, Institution, Association, or organisation in charge of or responsible for carrying out or proposing or, sponsoring the formation or widening of the road or improvement of the junction, or other works envisaged under this chapter, co-opted, if so desired by the, committee., , (3) The quorum for the meeting shall be four including the Convener and the, Chairperson., , (4) The Convener shall, considering the number of applications and urgency of the work, to be executed, convene the meetings of the Committee at such place and time, as may, be fixed in consultation with the Chairperson, by giving at least seven clear days, notice to all the members. Copies of plans pertaining to the applications, required, under these rules, along with the agenda notes containing technical report on all the, applications shall be forwarded to the members along with the notice., (5) The convener shall place before the Committee only such applications included in the, agenda notes circulated, which otherwise comply with all the provisions of these, rules, Master Plan / Detailed Town Planning Scheme / Interim Development Order in, force under the Kerala Town and Country Planning Act, 2016 (9 of 2016) , if any, for, that area and other relevant statutes, and shall issue permit as decided by the, Committee. The Convener shall also maintain detailed registers for the minutes and, for the land so surrendered., , (6) The Committee shall initiate and take actions to promote and monitor implementation, of the road scheme in total. The Committee may also promote land-pooling scheme, wherever feasible to enable the implementation of the scheme in total., , 66. Buildings part of which has been demolished for the purposes specified in rule 62.Notwithstanding anything contained in these rules, in the case of buildings part of which has, been demolished for the purposes specified in rule 62,even if the land is not freely, surrendered, Secretary shall permit construction or reconstruction of wall with or without, door(s), shutter(s) on the side abutting such road, without structural alteration., Provided that this rule is limited for the purpose of construction or reconstruction of such, wall on the side abutting the road affected by the widening/ development of the road., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 89
Page 100 :
90, , KERALA PANCHAYAT BUILDING RULES 2019, , 67., , CHAPTER XI, ACCESSORY BUILDINGS AND SHED, , Certain buildings and sheds exempted.-Permit, as per these rules, is not necessary for the, construction of any building used or intended to be used exclusively for the purposes of a, plant house or metre house, bathrooms or toilets or cabin for watch and ward or sheds for, keeping fuel or firewood for the domestic use of its owner or for keeping agricultural, implements, tools, rubbish or other materials or for watching crops or kennel for keeping, not more than six dogs or cattle shed for keeping not more than six cattle and their calves, or cage/aviary for keeping not more than twenty hens or ducks, all incidental to Group A1, residential occupancy building:, , Provided that area of such structures shall be limited to fifteen per cent of the open space., Provided further that the height of such structure(s) shall be limited to 2.5 metres., , Provided also that the distance from the boundary abutting the road to the accessory, building shall be equal to that necessary for a single storeyed residential building., , 68., , Provided also that the accessory building shall have minimum 1metre distance from the, boundaries and other building(s)., , Temporary hut or shed.- (1), The Secretary may grant permission to a person to, erect for a specified period or huts or sheds of a purely temporary nature for stabling or, similar purposes or hot mix plant or concrete mix plant, on general conditions as may be, fixed by the Council., (2), , The Secretary may, on the failure of the person to demolish or dismantle the shed or, hut or hot mix plant or concrete mix plant at the expiry of the period specified, cause, it to be demolished or dismantled and the cost thereof shall be recovered from such, person as if it were an arrear of property tax due under the Act, , (3) Application for permission to erect temporary hut or shed or hot mix plant or concrete, mix plant shall be submitted in white paper typed or written in ink, affixed with, necessary court fee stamp and accompanied by document to prove ownership or, consent of the owner, if the land is not owned by the applicant., (4) The Secretary shall, if convinced of the ownership, issue permit with or without, condition and specifying the period beyond which the hut or shed or hot mix plant or, concrete mix plant shall not be retained., CHAPTER XII, WALL AND FENCE, 69., , Prohibition of commencement of work. - The construction or reconstruction of any wall or, fence of whatever height bounding or abutting on any public street or public property or, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 90
Page 101 :
91, , KERALA PANCHAYAT BUILDING RULES 2019, public water course shall not be begun unless and until the Secretary has granted permission, for the execution of the work:, , 70., , Provided that any gate or grill or door or other structure shall not open or project into the, adjacent property or street., , Submission and disposal of application. -(1) An application to construct or reconstruct a, wall or fence shall be submitted in white paper, typed or written in ink and affixed with, necessary court fee stamp., (2) Application shall contain site plan and documents to prove ownership., , (3) The site plan shall clearly show all the streets, paths, lanes abutting or leading to the, plot and also contain a description of the materials used for the work., (4) Application fee shall be as in Schedule – I, , (5) The Secretary shall, if convinced of the plan and genuineness of the ownership, issue, permit not later than 15 days from the date of receipt of the application., , (6) A wall or fence abutting a street junction shall be sufficiently splayed as in rule 23(4)., 71., , (7) The permit fee shall be as in Schedule - II., , Completion report: - The owner shall on completion of the work submit a completion report, to the Secretary, in white paper typed or written in ink, specifying the date of completion., CHAPTER XIII, , SPECIAL PROVISIONS FOR CERTAIN CONSTRUCTIONS, 72., , Special provisions for addition etc. over buildings existing on the 30th March 2000.- (1), Notwithstanding anything contained in these rules, alteration or addition or extension of the, first floor or the second floor or both and or conversion or erection of roof, shutter or door, shall be permitted to buildings existing on the 30th May 1994 subject to sub - rules (2) to, (10)of this rule, even though the existing building and proposed floor(s) or work does not, satisfy the provisions under rules 23,26,28 and the provisions under Chapter V., Provided that alteration of existing building shall be permitted for the limited purpose, of constructing staircase or ramp or flight of steps for use as access to the proposed, floors, if such alteration satisfies the provisions under rule 23(2)., Provided further that the owner shall have no right to claim cost or compensation for, both the existing building and the proposed floor(s) or any portion thereof if the same is, required to be demolished in future for any road widening or development under any, scheme approved by Government or an authority under them:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 91
Page 102 :
92, , KERALA PANCHAYAT BUILDING RULES 2019, Provided also that the owner shall be responsible for the structural stability and other, safety of the building, both the existing and the proposed:, , (2), , (3), , (4), , (5), , (6), , (7), , (8), , Provided also that the alteration or addition (extension) or other works mentioned in, this rule above shall be permitted even if the existing building has one basement floor., , The proposed alteration or addition (extension) shall satisfy the provisions regarding, clearance from overhead electric lines specified under Table 2 of rule 22(5) and if such, clearance is not available, no objection certificate issued by the Chief Electrical, Inspector or an Officer authorised by him shall be produced for issuing permit., , The distance from the boundary abutting road to the proposed second floor over the, existing building having ground floor and first shall be that of the first floor, if the said, distance is less than that required under rule 23., The distance from the boundary abutting a road to the proposed first floor or first and, second floors over the existing building having ground floor, shall be that of the ground, floor, if the said distance is less than that required under rule 23., , In the case of residential or lodging houses and special residential or mercantile/, commercial buildings alteration or addition (extension) of floor(s) or conversion of roof, shall be permitted only if the existing building and the proposed floor(s) have average, 60centimetres open space from the boundaries of all the plots on its sides including, rear:, Provided that if any portion or side of the building abuts the plot boundary or have, an open space less than that specified above, a consent document issued by the, owner of the plot on the abutting portion/side shall be produced along with the, application for permit:, Provided further that not more than two sides shall be permitted to abut the boundary, even with such consent document., , In the case of occupancies other than that mentioned under sub-rule(5), alteration or, addition (extension) of floor(s) or conversion of roof shall be permitted only if the, existing building and the proposed floor(s) have average 1.00 metre open space from all, the plots on its sides including rear:, Provided that no industrial occupancy building under Group G2 and, hazardous occupancy building under Group I shall be permitted under this rule., , The maximum coverage permissible shall, if the proposed is for first and second floors,, be that of the ground floor over which such floors are proposed and if the proposal is, for second floor, be that of the first floor over which such floor is proposed:, , Provided that the proposed floor(s) shall not extend beyond the limits of the existing, building., , The maximum floor space index permissible under this rule shall be as in Table 6 under, rule 27(2) and for calculating the maximum floor space index, the built-up area of the, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 92
Page 103 :
93, , KERALA PANCHAYAT BUILDING RULES 2019, , (9), , proposed construction and built-up area of the existing building shall be taken into, account., , Off street parking shall be provided as in Table9&10 under rule 29 for the proposed, floor(s) irrespective of whether off street parking is available for the existing building, or not:, , (10) In the proposed alteration or addition (extension) of first and second floor(s) door shall, be permitted only on the side or portion having 1metre open space, window shall be, permitted only on the side or portion having minimum 60 centimetres open space and, no opening shall be permitted on the side or portion having less than 60 centimetres, open space., , 73., , Conversion of roof, shutters etc. of buildings existing before the commencement of these, rules:- (1) Conversion of roof with the same or a different material shall be permitted to, any building, irrespective of whether such building conforms to the provision in these, rules or not:, Provided that the clear distance of the roof edges from the plot boundaries shall not be, reduced from the existing distance, but however where sufficient distance is available,, it can be reduced to such extent that the provisions regarding projections permissible, into open space as provided in rule 26 is observed., , Provided further that no portion of the roof shall encroach or project into the street or, the neighboring plots and water from the roof shall not be allowed to fall into the street, or the neighboring plots or the plot boundaries:, , (2), , 74., , Provided also that no permission shall be necessary for conversion of roof with grass,, leaf or thatch:, , Conversion of shutters or doors with the same or a different material shall be permitted, in any building irrespective of whether such building conforms to the provisions in, these rules or not:, Provided that the area or height of the building shall not be increased., , Construction of additional sheet/tiled roof over the terrace of certain single family, residential buildings - (1) In the case of single family residential buildings upto three, storeys and height not exceeding 10 metres, Secretary may permit construction of, additional sheet/tiled sloping roof, over the terrace floor of such building for a maximum, height of 1.8m, if he is satisfied that:, (a), , (b), , such additional construction over the terrace is done for extra protection of such, terrace from rain, and not for any habitable use;, , such additional roofed terrace area is kept open on all sides and not enclosed fully, or even partly with wall/ grill / Window/ shutter/ any type of partition or the like,, other than:(i) parapet wall of height upto 1.20 metres,, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 93
Page 104 :
94, , KERALA PANCHAYAT BUILDING RULES 2019, (ii), , columns to support such additional roof,, , (iii) portion of such building, including the stair cabin leading to the terrace if, any,, , (iv) other structures such as water tank, rainwater harvesting arrangements and, the like, complementary to the terrace area;, (c), (d), , any projection of such additional roof into the mandatory yard is in accordance, with the provisions contained in these rules; and, the building, including such additional roof structure also comply with the, provisions of the Act and any other law applicable., , (2) Such terrace area covered with additional roof as in sub rule (1) shall not be reckoned to, calculate built-up area as per these rules, except for calculation of permit fee., , (3) The application fee and permit fee shall respectively be as stipulated in Schedule I and, Schedule II as for a pucca building., , (4) Under no circumstance, the height of building including the height of such additional, roof, shall qualify that for a high-rise building., , (5) Mandatory clearances, certificates of approval, NOC, concurrences etc. as per these, rules or bye laws made under the Act and any other law shall be obtained wherever, applicable., (6) Construction of additional sheet/tiled roof over the terrace of buildings for all, occupancies other than single family residential buildings upto three storeys and height, not exceeding 10 metres, shall be considered as another floor and shall be taken for the, calculation of all mandatory requirements as per these rules., , CHAPTER XIV, , WELLS, RAINWATER HARVESTING, , 75. WELLS (1) Essentially of permit.(i), , (ii), , No new well shall be dug without the permission of the Secretary., , Where any person intends to dig an open well /tube well/bore well, he shall submit an, application in the form in Appendix A1 to the Secretary, together with site plan and, documents to prove the ownership., , (iii) The site plan shall show the position and dimension of the well and all existing and, proposed buildings and structures in the site and within 7.5 metres radius from that, well., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 94
Page 105 :
95, , KERALA PANCHAYAT BUILDING RULES 2019, (2), , Setback.(i), , (ii), , The set back from any street shall be as that required for a building., , There shall be minimum 1.20 metres set back from other boundaries., , (iii) The well may be located within or abutting or away from the building in the plot., , (3), (4), (5), , (6), , (iv) No leech pit, sock pit, refuse pit, earth closet or septic tank shall be allowed or made, within a distance of 7.5 metres radius from any existing well used for supply of water, for human consumption or domestic purpose or within 1.2 m distance from the plot, boundaries., , Wall and surrounding: - The well shall be protected with brick wall with minimum 1 metre, height., , Fees: - The application fee and permit fee shall be as in Schedule I and Schedule II, respectively., , Approval of plan and issue of permit: -The Secretary shall, if convinced of the boundaries, and plan and bonafides of the ownership approve the plan with or without modification and, issue permit. In the case of tube wells, once the clearance from Ground Water Department is, obtained by the applicant and furnished, the Secretary shall issue the permit on the same day, of receipt of application along with prescribed fee., Validity and extension:(1), , The permit once issued shall be valid for three years and cannot be extended., , (7). Completion report: - The applicant shall submit a completion report to the Secretary, in white, paper typed or written in ink, specifying the date of completion., 76. RAINWATER HARVESTING, , 1. Groundwater recharging arrangements: -, , (1), Unless otherwise stipulated specifically in a Master Plan / Detailed Town Planning, Scheme / Interim Development Order in force under the Kerala Town and Country Planning, Act, 2016 (9 of 2016), workable ground water recharging arrangements shall be provided as, an integral part of all new building constructions through collection of roof top rainwater., (2), , The components of workable groundwater recharging arrangements, as stipulated in, sub rule(1) above, shall include:, (i), , (ii), , Roof gutters, Down pipe, , (iii) Filter unit, , (iv) Recharge well or recharge pond or percolation pit, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 95
Page 106 :
96, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that, open well or pond within the plot can be used as recharge components as, mentioned in item (iv) above., , (3), , (4), , 2., , Provided further that, filter unit as mentioned in item (iii) shall be mandatory only in, situations where rainwater is recharged directly to the groundwater through open wells,, pond and the like., , In exceptional cases such as water logging or impermeable subsoil conditions to, considerable depths, the ground water recharging arrangements for building, constructions need not be made mandatory., The owner(s)/occupier(s) shall maintain the roof tops and the groundwater recharging, arrangements in healthy/working conditions., , Rainwater storage arrangements: -, , (1), Unless otherwise stipulated specifically in a Master Plan / Detailed Town Planning, Scheme / Interim Development Order in force under the Kerala Town and Country Planning, Act, 2016 (9 of 2016), workable rainwater storage arrangements shall be provided as an, integral part of all new building constructions through the collection of roof top rain water for, all occupancies, except hazardous occupancy buildings and huts., (2), , The components of a workable rainwater storage arrangement, as stipulated in sub rule, (1) above, shall include: -, , (i), , (ii), , Roof gutters, , Down pipe and first flush pipe arrangement, , (iii) Filter unit and, (3), , (iv), , Storage tank with provisions for drawing water and spill over., , The minimum capacity of the storage tank, as stipulated in sub-rule(2)(iv) of the rain, water storage arrangement shall be at the rate given below:, Group A1, , 25 litres/sq.metre of Covered area, , Group B, , 50 litres/sq.metre of Covered area, , Group A2, Group C, , Group D, Group E, Group F, , 25 litres/sq.metre of Covered area, 50 litres/sq.metre of Covered area, , 50 litres/sq.metre of Covered area, , 50 litres/sq.metre of Covered area, , 25 litres/sq.metre of Covered area, , Group G1 & Group G2 50 litres/sq.metre of Covered area, Group J, , 25 litres/sq.metre of Covered area, , Note: - Covered area means the area mentioned in item (aa) of sub-rule (1) of rule 2., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 96
Page 107 :
97, , KERALA PANCHAYAT BUILDING RULES 2019, (4), (5), , 3, , The owner(s)/occupier(s) shall maintain the roof tops and the rain water storage, arrangements in healthy working conditions., , If both ground water recharging arrangements and rain water storage arrangements are, required to be provided as laid out in this chapter, in addition to rain water storage, arrangements, arrangements for carrying the spill over water from storage tank to, recharge well or recharge pond or percolation pit need only be provided., , Urban Forestry: - As per section 4 of The Kerala Promotion of Tree Growth in Non–Forest, Areas Act, 2005 (46 of 2005);, (1), , (2), , (3), , (4), , Every owner or occupant of a land other than single family residential building shall,, within a period of one year from the date of issue of occupancy certificate, plant trees, so as to conform to the standards prescribed by Secretary from time to time., Planting of trees shall be made at the rate of minimum of one tree per 450 sqm of plot, area for plots exceeding 450 sq. metres of area. Total number of trees would include the, existing trees in the plot also., A space of minimum 1 m X 1.5 m has to be provided for planting trees., , It shall be the duty of the owner or occupier of the land who is required to plant a tree or, trees to ensure that they grow properly., CHAPTER XV, SOLAR ASSISTED WATER HEATING/LIGHTING SYSTEM, , 77. Rooftop Solar Energy Installations. (1)The following categories of new buildings with, total built-up area exceeding 500 sq. metres shall be provided with Rooftop Solar Energy, Installations (Rooftop photovoltaic power station, or rooftop PV system) so as to generate, minimum 5% of the connected load: Group A1, , Apartment houses or residential flats, , Group C, , Medical or hospital buildings (with inpatients), , Group A2, Group D, , All buildings under Lodging houses and, special residential, , Community halls, Auditorium, wedding halls, , Provided that, there shall be provision for Rooftop Solar Energy Installations in the case, of single family residential building having built-up area for more than 400 sq.metres., , (2) Such buildings shall have open area on the roof top, which receives direct sunlight, where the Rooftop Solar Energy Installations can be installed., , (3) The Secretary shall, before issuing occupancy certificate, ensure that all new buildings, mentioned in sub rule (1) have completed installation of Rooftop Solar Energy, Installations., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 97
Page 108 :
98, , KERALA PANCHAYAT BUILDING RULES 2019, 78. Solar assisted water heating system in buildings - (1) All new buildings with total built-up, area exceeding 500 sq. metres in the following categories in which there is a system of, installation for supplying hot water shall also have an auxiliary solar assisted water heating, system:Group A1, Group A2, Group C, , Group D, , Apartment houses or residential flats, , All buildings under Lodging houses and, special residential, , Medical or hospital buildings (with inpatients), , Community halls, Auditorium, wedding halls, , Provided that, there shall be provision for solar water heater system in the case of single, family residential building having built-up area for more than 400 sq.metres., , (2) Such buildings shall have open area on the rooftop, which receives direct sun light, where the solar water heating system can be installed. There shall be provisions for, continuous water supply to the solar water heating system and for distribution of hot, water from the solar water heating system to various distribution points where hot water, is required through insulated pipe lines., (3) The water storage capacity requirements of the solar water heating system shall be, decided on each case by the registered Institution/Architect/Engineer/Building, Designer/Supervisor, as the case may be. The recommended minimum capacity shall, not be less than 25 litres per day for each bathroom and kitchen, subject to the condition, that maximum of 50% of the total roof area is provided with the system., (4) Specifications: Installation of Solar Assisted Water Heating Systems shall conform to, BIS specification IS 12933. The solar collectors used in the system shall have the BIS, certification mark., (5) The Secretary shall, before issuing occupancy certificate, ensure that all new buildings, mentioned in sub-rule (1) have completed installation of solar assisted water heating, system., , (6) Buildings under the purview of sub rule (5) of rule 5 shall follow Kerala State Energy, Conservation Building Code (KSECBC) Standards. Residential facilities, hotels and, hospitals with a centralized system (other than Systems that use heat recovery for at, least 1/5 of the design capacity) shall have solar water heating for at least 1/5 of the, design capacity., CHAPTER XVI, WASTE DISPOSAL, , 79. Waste management. - (1) Every new building shall be provided with provisions for, segregation of waste wherever applicable and safe disposal of waste., (2), , Every new building of built-up area exceeding 100 sq.metres shall be provided with, septic tank of suitable size unless it is connected to a public sewerage system or, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 98
Page 109 :
99, , KERALA PANCHAYAT BUILDING RULES 2019, , (3), , (4), (5), , (6), , (7), , sewage treatment plant. The design criteria and construction shall be as per the Code, of Practice for the septic tanks – IS 2470., , Every new residential building of built-up area exceeding 300 sq.metres shall be, provided with suitable systems such as bio gas plants etc. for the disposal of bio, degradable waste, unless there exist organized system for collection and disposal of, such waste. For all other occupancies waste management system as stipulated by, Pollution Control Board shall be provided., Leech pit, sock pit, refuse pit or septic tank shall have a minimum distance of 1.20, metres from the plot boundaries., In wedding halls where cooking and dining facilities are provided, proper and, adequate arrangements for collection and hygienic disposal of solid and liquid waste, shall be ensured to the satisfaction of the Secretary., , Water Re-use and Recycling: All buildings under Group A1 (Residential apartments, only) and A2 occupancy having total built-up area more than 2000 sq. metres shall, incorporate in-situ liquid waste management treatment plant and special provision, for recycling and reusing of waste water generated out of the use of water ., Water Re-use and Recycling: All buildings under B, C, D, E, F and J occupancies, having total built-up area more than 5000 sq. metres and all buildings under G1, G2, and I occupancy shall incorporate in-situ waste liquid waste management treatment, plant and special provision for recycling and reusing of waste water generated out of, the use of water., CHAPTER XVII, SAFETY PROVISIONS FOR HIGHRISE BUILDINGS, , 80., , (1), , 81., , High rise building - For the purposes of this Chapter, ‘high rise building” means a, building having a height of 16 metres or more, or with more than 4 floors (excluding, basement floor(s)), other than telecommunication towers /poles., In the case of high rise buildings, the provisions in these rules elsewhere shall apply, subject to modification in this chapter., , Safety provisions.-, , Staircase.(1), (2), , Every high rise building shall have at least two staircases, including fire escape, staircases., The height of the handrail in the staircase shall not be less than 90 centimetres and if, balusters are provided no gap in the balusters shall be more than 10 centimetres wide., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 99
Page 110 :
100, , KERALA PANCHAYAT BUILDING RULES 2019, (2), , Guard rails or parapets: (i), , Every balcony overlooking any exterior or interior open space shall be provided with, parapet walls or guard rails of height not less than 1.50 metres and such guard rails, shall be firmly fixed to the walls and slabs and may also be of blank walls, metal grills, or a combination of both., Provided that if metal grills are used they shall not be made of continuous horizontal, members to prevent climbing on them:, , (ii), (3)., , (4), , The spacing between the grills/ rails should be less than 10 centimetres., Fire escape staircase.-, , Every highrise building shall be provided with a fire escape stairway and shall be as, specified in rule 35., , Ducts: (i), , (ii), , (iii), , (iv), , (5), , Provided further that guard rails shall not be made of glass or any similar material, which are not reinforced to prevent breaking., , Every opening to interior or exterior duct shall be provided with protective covering, consisting of strong parapet wall having not less than 90 centimetres height from every, floor level and the portion above such parapet wall shall be provided with openable and, lockable shutters fixed with opaque or translucent glass which do not cause splinters, when broken; the shutters shall be provided with opaque metal sheets or with metal, grills or bars either in the front or on the rear., Parapet walls of 1.2metres height should also be provided around duct openings at the, terrace level. At the top of the duct, metal grills or bars may be provided either above or, below the top cover of the duct so as to reinforce the protection. The spacing between, the members shall not be more than10centimetres., , All windows at a height of not less than 2metres from ground level which can be, opened to an open space either interior or exterior shall be fitted with sufficiently strong, metal grills or bars in such a way that the spacing between the members is not more, than 10centimetres., All Openings at various floor levels to vertical duct, provided for the purpose of, lighting and ventilation shall be at a height of not less than 1.5metres from the, respective floor level. The openings shall be fitted with grill mesh of size not more than, 10centimetres x10centimetres, , Access: - The minimum width of access to a high rise building and plot as well as the, minimum existing width of the street giving access to the plot from the main street shall, be 5 metres or as prescribed elsewhere in these rules, whichever is higher., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 100
Page 111 :
101, , KERALA PANCHAYAT BUILDING RULES 2019, (6) Open spaces: (i), , (ii), , (iii), , (7), , (8), , (9), , Clear motorable open spaces of minimum 5 metres width to facilitate fire-fighting shall, be provided for the building at any two adjacent sides, of which, one is contiguous to, the street/access. Such motorable open spaces shall be kept free of vehicle parking or, any other erections or projections thereon other than projections of roof or weather, shade or cornices of not more than 75 centimeters width. However, ramp provided as, access to the basement floor can be given in this open space if through movement of, fire engine is not obstructed in any way., In case a group of buildings are to be constructed within any plot belonging to the same, owner or by different owners of adjoining lands jointly, the area of the land remaining, after accounting for the mandatory front, rear and side yards from the boundary of the, plot shall be considered as buildable area of the plot where the buildings may be, constructed subject to the conditions regarding floor space index, coverage, access,, light & ventilation etc. for the whole plot, distance between the various blocks within, this area shall be a minimum of 5 metres., , Adequate passage way and clearances required for fire fighting vehicles to enter the, premises shall be provided at the main entrance; the width of such entrance shall be not, less than 5 metres or as stipulated elsewhere in these rules, whichever is higher. If an, arch or covered gate is constructed, it shall have a clear headroom of not less than 5, metres., , Lift for residential apartments.-, , Every high rise apartment building having more than 16 dwelling units shall be provided with, at least one lift capable of carrying a stretcher:, , Provided that if only one lift is required for the building as per the rule 40, that lift shall be, one capable of carrying a stretcher., Parapets of terrace floor.-, , Where access is provided over the terrace floor or to the terrace floor, the edges of the terrace, floor shall be provided with parapet walls made of stable materials to a height of not less than, 120 centimetres., Structural design.-, , Application for construction or reconstruction or addition or alteration of any high rise, building shall be accompanied by one set of structural design, including that regarding, seismic forces as per the provisions contained in the National Building Code of India as, amended from time to time and certified drawings and a structural stability certificate, prepared and issued by a Structural Engineer., Provided that the provisions regarding the height of building as specified in the National, Building code of India, 2016 shall not apply to multiplexes., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 101
Page 112 :
102, , KERALA PANCHAYAT BUILDING RULES 2019, (10) Safety Plan:-, , In the case of High rise buildings, every application for approval shall be accompanied by, safety plan suitable for the proposed construction in accordance with the Health and Safety, Manual published by the Labour Department., , (11) Site supervision: (1), , (2), , (3), , The owner shall appoint a person, registered or deemed to have been registered under, the provisions of Chapter XXI, competent to supervise such works as per Appendix H2, of these rules, as full time supervising professional at the site, from the commencement, to the completion of the work. Such person shall have a minimum of 3 years of, experience in supervising works of similar nature., , Provided that, no activities shall be undertaken at the site in the absence of such site, supervising professional., , The owner shall intimate the Secretary, the details of the appointed supervising, professional including his/her date of appointment, photo identity proof and proof of, experience along with a copy of the acceptance of appointment duly signed by the, supervising professional. The owner shall also intimate the Secretary in writing about, replacement, if any, of such supervising professional together with all details specified, above without any delay., Provided that if the work is executed through any person/persons or agency/agencies, like developer, the responsibility of appointment of site supervising professional as, stipulated in this rule shall be vested with such person/persons or agency/agencies., The supervising professional shall: (i), , (ii), , (iii), (iv), (v), 82., , Ensure that the construction is carried out as per the approved plans,, specifications and structural design., , Take adequate safety precautions at all stages of construction or reconstruction or, addition or alteration or repair or demolition or removal of the various parts of the, building for safe guarding the life of workers and public against hazards, consequent on any aspect of the work., Ensure that all protective works carried out to safe guard the adjoining properties, during construction are sufficient and in good order to ensure safety., , Ensure at every stage of construction, that the quality of construction and/or, materials used for construction is as per the specifications for that work., , Ensure that the debris, construction wastes or materials are safely and clearly, disposed., , Display of the details of the permit etc.(1) For the entire period of construction, the owner, shall display the details of the building permit near the entrance to the site in a board of size, not less than 100 centimetres X 75 centimetres. The details to be displayed include the date, and the number of building permit, name and address of the owner and developer with phone, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 102
Page 113 :
103, , KERALA PANCHAYAT BUILDING RULES 2019, number, the occupancy group of the building, the number of floors, coverage, F.S.I., area, earmarked for parking in sq.metres and the use in each floor., , (2) Prior to commencement of the construction, all sides of the plot shall be covered, with protective fencing and screen to ensure safety and convenience of the adjoining, properties. Such protective fencing and screen shall be retained throughout the, construction period., , (3) Adequate safety measures shall be ensured by the owner and the developer for, protection against damage to health, life, buildings and property of the inhabitants, around, during and after building construction and land development. The owner and, developer shall be solely responsible for any such damages., CHAPTER XVIII, , TELECOMMUNICATION TOWERS, , 83., , Essentiality of permit. - No person shall erect or re-erect any non-Governmental, telecommunication tower or telecommunication pole structures or accessory rooms or, make alteration or cause the same to be done without first obtaining a separate permit for, each such tower or telecommunication pole structures from the Secretary., , 84., , Special Provisions.-, , 1. Distance from road and boundaries.(i), , (ii), , (iii), , The base of the tower or poles shall have minimum 3 metres distance from the plot, boundary abutting the road, whether it is proposed on land or over a building, even if, the building is having less than 3 metres distance:, Provided that the distance from road boundary of the accessory rooms such as, equipment rooms, shelters, or generator rooms proposed over a building shall be that of, the building., , In addition to the distance specified under sub rule (1)(i), set back required for road, widening proposed in any Master Plan / Detailed Town Planning Scheme / Interim, Development Order in force under the Kerala Town and Country Planning Act, 2016 (9, of 2016), shall also be provided., , Distance from other boundaries of the plot to the base of the telecommunication tower, or pole or structure or accessory rooms shall be minimum 1.20 metres:, , Provided that if the telecommunication tower or pole structures or accessory rooms are, proposed over a building, the distance from the boundaries other than that abutting a, road, shall be that of the existing building;, Provided further that if the building abuts any plot boundary and the telecommunication, tower or pole structures or accessory rooms are also proposed to abut that boundary, then consent of the owner of the plot on the abutting side shall be obtained and, produced along with the application for permit:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 103
Page 114 :
104, , KERALA PANCHAYAT BUILDING RULES 2019, , (2), , Provided also that no portion of the telecommunication tower, pole structure or, accessory room shall project or over hang into the neighboring plots., , Provisions regarding F.S.I. and height.-, , The provisions regarding F.S.I., coverage, height restriction with regard to width of road and, distance from the boundary abutting road and dimension of parts of building shall not apply, to telecommunication towers or pole structures or accessory rooms such as equipment rooms,, shelters or generator rooms., , Provided that the height of the telecommunication towers or pole structure or accessory, rooms, including the height of the building if they are proposed over a building, shall be, restricted as in sub rule(2)and (3) of rule 24., Provided further that additional distance from boundary abutting the road and other, boundaries of the plot proportionate to increase in height of the tower shall not be necessary, for the telecommunication tower or pole structures or accessory rooms or for the building, over which they are proposed., , (3). Accessory rooms. (i), Accessory rooms such as equipment rooms, shelters or generator rooms essential for, the service shall be permitted along with a telecommunication tower or, telecommunication pole structure or separately, if a request is made in the application, and plans/drawings of the rooms are attached either along with the application for, permit or separately., (ii), , (iii), , (iv), , The cabin may be made with any material but the area of such cabin shall not exceed 15, sq.metres and the installation of electricity generator is allowed with insulated soundproof cabin only., , Every construction or installation, ancillary or necessary for the telecommunication, system shall conform to the relevant rules applicable to such construction or installation, and license or permit required under such rules shall also be obtained., The telecommunication tower or ancillary structures shall not prevent or block the, access, exit or entry or reduce the width of such access, exit or entry of building or in, no way badly affect the safety measures or amenities provided in the building in which, it is erected., , (4) Electrical line clearance. - Every tower or ancillary construction shall satisfy the minimum, vertical and horizontal clearance from electrical lines as stipulated in the Indian, Electricity Act, 1910 and Indian Electricity Rules, 1956 as amended from time to time, and also any regulation issued by the State Electricity Board., (5) Protective Wall.(i), , Every tower erected on the ground and through which electric power is transmitted or, passed shall be provided with protective wall or grill at a distance of one metre from, any point of the base., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 104
Page 115 :
105, , KERALA PANCHAYAT BUILDING RULES 2019, (ii), , The wall or grill shall have a minimum of 1.20 metres height and shall be kept under, lock and key, if provided with door., , (6) Protection from lightning. - Every telecommunication tower shall be provided with sufficient, protection against lightning, conforming to I.S. 2303-1969-Code of Practice, as, amended from time to time., (7) Warning lights and colour specifications.-, , (i) Every telecommunication tower shall be provided with two Aviation Warning Lights, (ANL) each at 40 metres and 70 metres height from the ground level and one at the top,, the two lights at 40 metres height shall be fixed in one set of opposite and that at 70, metres height shall be fixed at the other set of opposite corners., , (ii), , 85., , 86., , 87., , Every telecommunication tower shall be painted with international orange and, international white colors alternatively each with 5 metre band, starting with, international orange at the top., , Damage and liability.- (1) The applicant/owner shall be responsible for the structural, stability of the telecommunication tower and the building in which it is erected and for any, damage caused due to inadequate safety measures., (2) Erection of any telecommunication tower or pole structures or accessory rooms, shall be permitted only over authorised buildings which are structurally safe., , Site approval etc.-, , (1) No site approval shall be necessary for the construction of telecommunication, towers, telecommunication pole structures or accessory rooms essential for such, service., (2) Telecommunication towers or pole structures or accessory rooms shall be permitted, in any zone of Master Plan / Detailed Town Planning Scheme / Interim Development, Order in force under the Kerala Town and Country Planning Act, 2016 (9 of 2016),, if any, or over any building irrespective of its occupancy., , Submission of application and its disposal.- (1) Application for permit shall be, submitted to the Secretary in the form in Appendix A1along with two copies of site plan,, location, elevation, sectional elevation, structural stability certificate if required as per, these rules, copy of agreement executed with department of Telecommunications or, license or permit issued by an authority approved by Government of India from time to, time and document to prove ownership., , Note. - (1) Ownership document may be a sale deed or mortgage deed or deed of agreement, or license or consent document, etc., (2), , No structural stability certificate shall be necessary in the case of telecommunication, pole structures and accessory rooms., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 105
Page 116 :
106, , KERALA PANCHAYAT BUILDING RULES 2019, (3), (4), , (5), , (6), , In case the telecommunication tower is proposed above any building, structural, stability certificate shall be submitted in respect of that building also., The site plan shall show plot dimensions, access street width, details of existing, structures within the plot with their uses, height, number of floors, set back from the, plot boundaries and between them; proposed tower and ancillary structures., , The structural stability certificate shall be prepared and issued by a Structural, Engineer registered as per these rules. In the case of towers erected by Central or, State Government or Quasi- Government Organisation, the structural stability, certificate may be prepared and issued by a competent engineer employed in such, firms. The drawings submitted shall also be duly certified for the structural stability., Application fee shall be Rupees one thousand and permit fee shall be: (a) For towers of any height, rupees ten thousand;, , (b) For pole structures (one unit with any number of poles) rupees two thousand and, five hundred., , (7), (8), , (9), , (c) No separate application fee shall be necessary for the accessory rooms essential, for the use of telecommunication tower or pole structures but permit fee shall be, remitted corresponding to their area as in the case of a pucca building., , For the purpose of levying fee, the height of the tower shall be taken from the base, of the tower and not from the base of the building., , The Secretary shall, if convinced of the boundaries and ownership of the plot, plan, and drawings and genuineness of the certificates, issue permit, not later than 15 days, from the date of receipt of the application., The permit issued under sub rule(8)shall be a work permit and the construction or, erection of telecommunication tower or telecommunication pole structures or, accessory rooms essential for the use of such tower or pole structures shall be, completed within one year from the date of issue of the permit., , (10) The period of the permit shall be extended for a further period of one year if an, application for the same is submitted to the Secretary, within the valid period of the, permit., , (11) The application for extension of the period of permit shall be submitted in white, paper, typed or written in ink, affixed with necessary court fee stamp; original permit, shall also be attached., (12) No application fee shall be necessary for extension of period of permit but fee for, extension shall be equal to fifty per cent of the fee for original permit in force at the, time of extension., , 88. Completion Certificate.- (1) After completion of the work of the telecommunication tower, or pole structures and accessory rooms as per permit, the applicant and the engineer, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 106
Page 117 :
107, , KERALA PANCHAYAT BUILDING RULES 2019, shall submit to the Secretary completion certificate as in Appendix E1 and Appendix E3, respectively, along with a certificate of structural safety/stability of the tower and the, building, if the tower or pole is constructed over a building., , (2) The Secretary shall, if satisfied that the work has been completed as per permit, issue, use certificate as in Appendix F2 not later than 15 days from the date of receipt of, the completion certificate allotting a number, included in a different series from that, allotted to buildings, on the basis of which the authorities concerned may allow, power connection, etc. for use of the service., Provided that if no such use certificate is issued within the said 15 days, the, applicant/owner may proceed as if such use certificate has been duly issued to him., CHAPTER XIX, , 89., , ACTION AGAINST UNAUTHORIZED CONSTRUCTIONS, , Deviation during construction and power of Secretary to require alteration in work.- (1), The applicant shall, if he intends to make any deviation from the approved plan or, specification, submit revised plans and drawings and obtain permit afresh, against the, previous permit., Provided that in such cases the permit fee in excess of the original permit fee already, remitted need only be paid and the date of expiry of the permit shall be that of such, previous permit;, , Provided further that no permit is necessary for effecting minor deviations such as, shifting the position of access to plots in the case of lay outs and shifting the position of, rooms, stairs, lifts, windows, doors or ventilators and their sizes in the case of building, constructions if they do not conflict with these rules;, , (2), , Provided also that the deviations mentioned in the above proviso shall be incorporated, in the completion plan and submitted along with completion certificate., (i), , (ii), , Where it comes to the notice of the Secretary that a work:-, , is not in accordance with the plans or specifications approved;, , is in contravention of any of the provisions of the Act or these rules, bye-law or, declaration made there under;, , he may, by notice, require the person for whom such work is done:(a), , (b), , to make such alterations as may be specified in the notice with the object of, bringing the work in conformity with the plans or specifications approved, or the provisions so contravened; or, to show cause why such alterations should not be made;, , within such period as may be specified in the notice:, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 107
Page 118 :
108, , KERALA PANCHAYAT BUILDING RULES 2019, Provided that any construction carried out in deviation of the approved plan or specific, conditions, shall not be required to be altered as per the approved plan if such, construction does not violate the provisions or specific conditions contained in the Act, or these rules., , (3) Where the person to whom the notice under sub-rule (2) is issued does not show cause, as aforesaid, he shall be bound to make the alterations specified in such notice., , (4) Where the person to whom the notice under sub-rule (2) is issued shows sufficient, cause as aforesaid, the Secretary may, cancel the notice and in other cases, by order, confirm or modify the notice., , 90. Demolition or alteration of work unlawfully commenced, carried on or completed.- (1), Where the Secretary is satisfied(a), , that the construction, reconstruction or alteration of any building or digging of, any well:-, , (i) has been commenced without obtaining the permission of the Secretary or in, contravention of the decision of the Council; or, , (ii) is being carried on, or has been completed otherwise than in accordance with, the plans or specifications on which such permission or decision was based;, or, , (b), (c), , (2), , (iii)is being carried on or has been completed in breach of any of the provisions, contained in the Act or these rules or bye-law or order made or issued, thereunder or any direction or requisition lawfully given or made, thereunder; or, that any alteration required by notice issued regarding deviation has not been duly, made; or, that any alteration of or addition to any building or any other work made or done, for any purpose in or upon any building has been commenced or is being carried, on or has been completed in contravention of the provisions regarding accessory, buildings and sheds., , he may make a provisional order requiring the owner or the person for whom the work, is done to demolish the work done or so much of it as, in the - opinion of the Secretary,, has been unlawfully executed or to make such alterations as may, in the opinion of the, Secretary, be necessary to bring the work in conformity with the provisions of the, Act, these rules, bye-laws, direction, order or requisition as aforesaid, or with the plans, and specifications on which such permission or decision was based, and may also direct, that until the said order is complied with, the owner or such person shall refrain from, proceeding with the work., The Secretary shall serve a copy of the provisional order made under sub-rule (1) to, the owner or the person for whom such work is done together with a notice requiring, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 108
Page 119 :
109, , KERALA PANCHAYAT BUILDING RULES 2019, , (3), , (4), , (5), , (6), , 91., , him to show cause within a reasonable time to be specified in such notice why the, order should not be confirmed., , Provided that, any construction or reconstruction or addition or alteration of any, building or digging of any well, commenced, being carried on or completed without, obtaining approved plan or in deviation of the approved plan shall not be directed to, be altered or demolished, if such construction or reconstruction or addition or, alteration of building or digging of well does not violate any provisions or specific, conditions contained in the Act or these rules and may be considered for, regularization under the provisions in these rules., Notwithstanding anything contained in sub-rule (2) or sub-rule (3),the Secretary may, also initiate prosecution proceedings against the owner or the person for whom the, work has commenced, being carried on or has been completed., The Government may, either suomotu or on application made by any person, aggrieved, after examining the records and giving an opportunity to be heard for the, applicant and the person who has carried out the construction or reconstruction or, alteration or addition of any building or any structure or digging of any well as in, sub-rule (1)and Secretary, if convinced that the construction or reconstruction or, alteration or addition of the building the structure or digging of the well has been, carried out violating the provisions contained in the Act or these rules or any other, rules issued under the Act or any lawful direction issued by the Government or, Secretary, direct the Secretary to revoke the permit and/or stop the work and/or, require to modify the construction and/or demolish the construction or, reconstruction or alteration or addition or fill up the well within a period to be, specified in that direction. The Government may also directly revoke the permit, and/or stop the work in such cases., , The Government may, if the Secretary fails to execute the direction issued under, sub-rule (5) to demolish a construction or reconstruction or alteration or addition or, fill up the well within the period specified therein, make necessary arrangements for, the same and may recover the expenses from the Panchayat concerned., , Order of stoppage of building works in certain cases:- (1), Where the erection of, any building or the execution of any work has been commenced or is being carried on (but, has not been completed) without obtaining the permission of the Secretary or in, contravention of any decision of the Council or any provision in the Act or these rules or, byelaws made there under or any lawful direction or requisition given or made under the, Act or these rules or byelaws made there under, the Secretary may without prejudice to, any other action that may be taken under these rules, by order require the person at whose, instance the building or the work has been commenced or is being carried on, to stop the, same forthwith. The status of the work at the time of issuance of stoppage of work may be, noted by Secretary., (2) Where the order under sub-rule (1) is not complied with, the Secretary may require, any police officer to remove such person and all his assistants and workmen from, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 109
Page 120 :
110, , KERALA PANCHAYAT BUILDING RULES 2019, the premises within such time as may be specified in the requisition and such police, officer shall comply with the requisition accordingly., , (3) After the requisition under sub-rule(2) has been complied with, Secretary may, if he, thinks fit, require in writing the assistance of a police officer or depute by a written, order an officer or employee of the Panchayat to watch the premises in order to, ensure that the erection of the building or, execution of the work is not continued, and the cost thereof shall be paid by the person at whose instance such erection or, execution was being continued or to whom notice under sub-rule(1) was given, and, shall be recoverable from such person as an arrear of property tax under the Act., , CHAPTER XX, , REGULARISATION OF UNPERMITTED CONSTRUCTIONS AND DEVIATIONS, 92., , Power of the Secretary to regularise certain constructions. - The Secretary shall have, the power to regularise construction or reconstruction or addition or alteration of any, building or digging of any well or telecommunication tower or any structure or land, development or any other work for which permission of the Secretary is necessary under, this rule commenced, being carried on or completed without obtaining approved plan or in, deviation of the approved plan:, Provided that such work shall not be in violation of any of the provisions of the Act or, these rules., , Provided further that permit may be granted for continuing works already commenced, without obtaining permit after levying fee equivalent to the compounding fee for, regularization as per these rules for such part already constructed and permit fee for the, remaining unconstructed part;, Provided further that such power shall not relieve the Secretary of his responsibility in, detecting and preventing such work and in taking other actions as per these rules:, , 93., , Provided also that where the work was commenced, being carried on or completed after, the statutory period specified in rules 14, 49(6), 70 or 87 and as per rules, such work, shall be considered as duly permitted and not one requiring regularisation., , Submission of application and procedure for its disposal. - (1) Application, regularization shall be submitted in the form in Appendix A1., (2), , for, , The application for regularization shall be accompanied by documentary evidence of, ownership of plot, site plan, elevation, building plan, service plan, parking plan, wherever the building requires parking, and other details and specifications as are, necessary in the case of an application for new building permit; in the case of, deviation from approved plan, the approved plan and permit already obtained shall, also be submitted., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 110
Page 121 :
111, , KERALA PANCHAYAT BUILDING RULES 2019, (3), 94., 95, , Application fee: - The application fee shall be as specified in Schedule I., Decision to be intimated: - (1), refuse to grant regularization., (2), , (3), , (4), , (5), , 96., , The procedure for disposal of an application for regularisation shall be that followed, in the case of an application for new permit., The Secretary shall by written order either grant or, , The Secretary shall, if the decision is to grant regularisation intimate the fact to the, applicant in writing specifying the amount to be remitted as compounding fee and, the period within which the amount has to be remitted., The Secretary shall, on receipt of the compounding fee, and compliance of the, condition, if any specified, issue order as in Appendix-G1 absolving the person from, all liabilities and regularizing the construction, and record the details thereof in a, register to be kept as a permanent documents in the form in Appendix – G2., The compounding fee shall be double the permit fee in force., , Provided that in the case of deviated or additional construction only the area so, deviated or added shall be considered for the calculation of compounding fee., , The Secretary shall, if the decision is to refuse regularisation, intimate the fact to the, applicant specifying the reasons for such refusal and the period within which, such building or part of building has to be demolished or the well filled up:, Provided that an application for regularisation shall be refused only on such grounds, on which approval of site or permission may be refused., , Demolition of buildings not regularised.- (1) Where the owner fails to demolish the, building or structure or part thereof or fill up the well as directed in the order refusing, regularisation or fails to remit the compounding fee within the time specified, or fails to, comply with any condition stipulated in the order granting regularisation within the time, specified, the Secretary shall himself cause the building or part thereof demolished or the, well filled up as the case may be, and the expenses thereof shall be recovered from the, owner as if it were an arrear of property tax due under the Act:, Provided that in the case of an order refusing regularisation, the building or part thereof, shall not be demolished or well filled up or prosecution initiated as in sub-rule (2) until, and unless the time prescribed for filing appeal from such an order has not been, expired., , (2) Notwithstanding anything contained sub-rule (1), Secretary may also take prosecution, proceedings against the owner., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 111
Page 122 :
112, , KERALA PANCHAYAT BUILDING RULES 2019, CHAPTER XXI, , REGISTRATION OF INSTITUTION, ARCHITECTS, ENGINEERS, TOWN PLANNERS,, ETC., 97., , 98., 99., , Plans and drawings to be prepared and signed by Architect, etc. - In these rules, wherever it, is required that a plan or drawing or specification shall be one prepared and signed by or a, certificate shall be one so certified and signed by an Institution, Architect, Building, Designer, Engineer, Town Planner or Supervisor and such Institution, Architect, Building, Designer, Engineer, Town Planner or Supervisor shall be a person registered or deemed to, have been registered under the provisions in this chapter., An Institution under any university in the state, offering Bachelor’s degree and/or, Master’s degree in Architecture and/or Civil Engineering may also register under the, provisions in this chapter. In such situations, the Head of Department of Architecture or, Civil Engineering as the case may be, shall certify and sign the plan or drawing or, specification, affixing the official seal of the department., , Registering Authority. - The Regional Joint Director, Urban Affairs Department, shall be the, Registering Authority for the respective regions of the State., , Application and procedure for registration.- (1) Any person or institution having the, requisite qualification may submit an application for registration in the form in AppendixH1-A or Appendix H1-B as the case may be., (2), , (3), , A person employed in the service of Government or Quasi-Government or, Government owned Corporation or Board, Authority or Government Companies, or Banks is not eligible for registration., Provided that paid Apprentices under the Apprentices Act,1961 (Central Act 52, of 1961) are considered as not employed for this purpose., , The application shall be affixed with necessary court fee stamp and shall be attached, with true copy of certificate showing educational qualification and experience., , In the case of institutional registration, true copy of the following documents shall be, attached with the application affixed with necessary court fee stamp:-, , (4), , (i), , valid registration/recognition of Bachelor’s degree course in Architecture, from Council of Architecture or that in Civil Engineering from All India, Council for Technical Education (AICTE) as the case may be, and, , (ii), , affiliation of the institution to a university in the State, , The Registering Authority shall, if convinced of the genuineness of the documents,, issue registration certificate in the form in Appendix-H3 after collecting the, registration fee., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 112
Page 123 :
113, , KERALA PANCHAYAT BUILDING RULES 2019, (5), , The registration once made shall be valid for four years from the date of registration, certificate. The registration certificate shall be renewable on payment of renewal fee, with a request in white paper affixed with necessary court fee stamp made within the, valid period of registration. In the case of institutional registration, true copy of, document(s) showing valid registration/recognition of Bachelor’s degree course in, Architecture from Council of Architecture or that in Civil Engineering from All, India Council for Technical Education (AICTE) as the case may be, shall also be, attached with the application for renewal., Provided that if the registration could not be renewed within the said valid period,, the registering authority shall, on receipt of the application, renew the registration, collecting a fine 50 per cent of the registration fee in case of delay up to 30 days and, with a fine 100 per cent of the registration fee in case of delay upto 60 days from the, date of expiry of the registration, in addition to the registration fee as per these rules., Provided further that a license issued under the Kerala Muncipality Building Rules,, 1999 shall be deemed to have been issued under these rules and shall continue to be, valid for the period for which that license was issued and the holder of the said, license shall be eligible for registration under these rules., , (6), , Provided also that in the case of Institutional registration, any change of person in, the capacity of the Head of Department of Architecture or Civil Engineering, as the, case may be, shall be officially intimated by the Principal/Head of Institution to the, registering authority with name and specimen signature of such person., The fee for registration and renewal shall be the same and shall be at the rates shown, below:, Institution (Architecture), : Rs 6000, Institution (Civil Engineering) : Rs 6000, Building Designer A, : Rs 6000, Building Designer B, : Rs 5000, Engineer A, : Rs 6000, Engineer B, : Rs 5000, Town Planner A, : Rs 6000, Town Planner B, : Rs 5000, Supervisor Senior, : Rs 4000, Supervisor A, : Rs 3000, Supervisor B, : Rs 2000, , 100. Qualification for registration. - No person shall be eligible for registration in the category in, column (1) unless he possesses the qualification as in column (2) of Appendix-H2, , 101. Registration in more than one category. - A person shall be eligible for registration in more, than one category if he possesses the requisite qualification and submits separate application,, and fee for registration in each such category., FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 113
Page 124 :
114, , KERALA PANCHAYAT BUILDING RULES 2019, 102. Certification of Professionals for KSECBC compliance .- (1) A person who fulfils the, eligibility criteria specified in the Energy Conservation (Minimum qualification for Energy, Auditors and Energy Managers) Rules, 2006 and has qualified National Examination for, Energy Conservation Building Codes Compliance, (2), , The Empanelled Energy Auditors (Building), whose services are engaged by the, owner, shall(a) verify and certify –, i. the design of the building keeping in view the design criteria, energy goals of, the project, energy systems performance verification plan, and the modelling, approach;, ii., the energy conservation measures based on the design approach for the, project under consideration;, iii., construction documents and compliance documents, compliance forms and, checklists specified to ensure that the building complies with the Code and, these rules;, iv., energy performance index ratio of the proposed building;, (b) furnish a certificate under its seal and authorized signature to the effect that, drawings, specifications, construction documents, compliance documents and, forms prepared covering building envelope, comfort system and controls, lighting, and electrical power systems, wherever applicable, and all other Code related, documentation prepared for submission to the authority having jurisdiction, ensuring compliance with these rules;, (c) inspect the building works from the design stage to its commissioning stage of, buildings including their uses under these rules and based on his certification, the, authority having jurisdiction shall issue building permit, approve construction of, building, issue completion and occupancy certificates;, (d) the Empanelled Energy Auditors (Building) shall ensure that none of the, professionals or employees working under him/her is engaged in any work in, connection with the construction or alteration of the concerned building covered, under these rules to ensure that there is no conflict of interest with his/her official, duties with the interests of the authority having jurisdiction;, (e) report to State designated agencies on such unusual technical issues that may arise, due to issue of building permit or construction of building or during occupancy, stage;, (f) provide inputs to the National and State Energy Conservation Building Code, Implementation Committees to facilitate for better implementation of the Kerala, State Energy Conservation Building Code and Kerala Energy Conservation, (Building Code) Rules 2017;, (g) promote norms and standards specified in the Kerala State Energy Conservation, Building Code, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 114
Page 125 :
115, , KERALA PANCHAYAT BUILDING RULES 2019, CHAPTER XXII, THE KERALA URBAN ARTS COMMISSION, 103. Constitution of the Commission. - (1) The constitution and functioning of the commission, shall be as per Kerala Town and Country Planning Act, 2016 (9 of 2016), , (i) Notwithstanding anything contained in these rules and with due regard to the, conservation of buildings, precincts and natural features of heritage value, the, commission shall have powers to recommend to permit or recommend to decline land, developments, uses and constructions including additions, alterations demolitions etc.,, within the areas identified or advised by the commission as having heritage value., , (ii) The Panchayat shall seek such recommendations of the commission, and the, recommendations of the commission shall be binding to the Panchayat including any, particular architectural or aesthetic form of construction in the case of land, developments and constructions in such area., , (2), , Not withstanding anything contained in these rules, for buildings more than 20, floors and certain areas suggested by the Government, Kerala Urban Arts, Commission may enforce urban design and architectural control to the buildings and, open spaces. These shall be detailed out keeping in view of the location, characteristics development requirements for the area., , CHAPTER XXIII, VIGILANCE, DANGEROUS AND DEFECTIVE WORKS, APPEAL, ETC., 104. Secretary to submit report. - (1), Secretary shall submit to Government every three, months report with respect to the following:(i), , (ii), , total number of applications for building permit received during the period;, , total number of applications in which building permit was issued and or refused;, , (iii) details of applications in which decision was not taken within the stipulated time, specified as per these rules as the case may be, from the date of receipt and the, reasons therefore;, (iv) details of applications referred to the Council, by the applicant, (v), , total number of applications received for regularisation, of unauthorized or, deviated constructions;, , (vi) total number of applications for regularisation disposed of specifying the number, of applications sanctioned and or refused, if refused, details of further action, taken;, (vii) number of applications for regularisation pending, disposal;, , (viii) total number of illegal constructions detected and action taken thereon; and, (ix) details of Government directions received and action taken thereon., , (2) Government shall, after considering the report, take action as they deem proper., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 115
Page 126 :
116, , KERALA PANCHAYAT BUILDING RULES 2019, 105. Vigilance. - (1) There shall be a State Level Vigilance wing headed by the Chief Town, Planner (Vigilance) under the Local Self Government Department to perform the functions, entrusted by Government by order from time to time with regard to vigilance functions, pertaining to building constructions and land developments., (2) All District Town Planning offices will render assistance to the State Level Vigilance, wing for inspections and reporting building constructions and land developments., (3) The District Police Officer shall render all assistance to the Chief Town Planner, (Vigilance), if so requested, for discharging their duties., , 106. Stoppage of dangerous or defective works. -(1) Notwithstanding anything contained in, these rules, the Secretary may, at any time stop the construction or reconstruction or, alteration of any building, if in his opinion, the work in progress is a danger to human life., , (2) The Secretary shall have the power to condemn any work or material which in his, opinion is unsatisfactory or as per the direction given by the Chief Town Planner, (Vigilance)or is likely to constitute a danger to health and any work or material so, condemned shall be remedied, amended or made good or shall be removed in full or in, part and replaced by new work or material, to the Satisfaction of the Secretary., , 107. Penalty for unlawful building.- (1) The owner of a building or well and the registered, institution / Architect / Engineer/ Town Planner/ Supervisor who has made a certificate under, rule 6 (3) as specified in Annexure J1 with respect to the construction under consideration or, a person to whom notice is issued under these rules shall, where the construction or, reconstruction of such building or tower or any structure or digging of such well –, (a), , is commenced without the permission of the Secretary; or, , (c), , is carried on or completed in contravention of any lawful order or in breach of, any provision contained in the Act or these rules, or bye-law made there under or, any direction or requisition lawfully given or made; or, , (b), , (d), (e), , is carried on or completed otherwise than in accordance with the particulars on, which such permission was based; or, , about which any alteration or addition required by any notice issued by the, Secretary under these rules, is not duly made: or, , about which a direction, if any, given by the Secretary under these rules is not, complied with,, , be liable, on conviction by competent court, to a fine which may extend, in the case of, building to ten thousand rupees and in the case of a well or hut to one thousand rupees, and to a further fine which may extend in the case of a building to one thousand rupees, and in the case of a well or hut to two hundred and fifty rupees for each day during, which the offence is continued:, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 116
Page 127 :
117, , KERALA PANCHAYAT BUILDING RULES 2019, , (2), , (3), , Provided that if any construction or reconstruction of a building or digging of a well, unlawfully carried out by a person has been regularised by the Secretary, he shall not be, punished., Where any building, erected in violation of any standard or condition or direction, lawfully issued under the provisions of the Act or these rules, becomes a threat to, public safety or to human life, the owner or builder and the registered institution /, Architect / Engineer/ Town Planner/ Supervisor who has made a certificate under rule 6, (3) as specified in Annexure J1 with respect to the construction under consideration of, such building shall on conviction by a competent court, be punishable with, imprisonment which may extent to one year., The Secretary may take prosecution proceedings under sub-rule (1) or sub-rule (2)., , 108. Appeal.- (1) Any person aggrieved by an order passed by the Secretary may submit an, appeal to the Tribunal for Local Self Government Institutions constituted under section 271 S, of the Kerala Panchayat Raj Act, 1994., (2), , Without prejudice to the provisions contained in the Act, an appeal may be filed against, any order, –, (i), , (ii), , approving or disapproving building site;, , granting or refusing permit to execute work;, , (iii) confirming, modifying or cancelling the notice requiring alteration of work;, , (iv) confirming the provisional order requiring demolition of building or part thereof, or filling up of well;, (v), , regularising construction or reconstruction or alteration of building or digging of, well erection of telecommunication tower or pole structure, conversion or, erection of shutter or door, conversion of roof, etc. or rejecting such, regularisation; and, , (vi) stopping erection of building or execution of work., , (vii) passed or action taken by the Secretary under these rules;, , (viii) issued on the basis of the decision of the Special Committee;, (3), , (ix) passed by the Chief Town Planner or the District Town Planner., , Any person aggrieved by any of the action in the discharge of the administrative, functions by the local self government institutions or an employee or an officer of the, local self Government institutions as explained herein may submit there grievances to, the ombudsman for redressal., , Ombudsman is an authority constituted for Local Self Government Institutions at the, state level for conducting investigations and enquires in respect of any action involving, corruption or maladministration or irregularities in the discharge of administrative, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 117
Page 128 :
118, , KERALA PANCHAYAT BUILDING RULES 2019, functions of the Local self Government Institutions or by an employee or an officer, working under Local self Government Institutions or by an employee or an officer, working in any office or institution transferred to such Local Self Government, Institutions or by elected member of Local Self Government Institution including its, President or Chairperson and for the disposal of such complaints in accordance with the, provisions of section 271(G) of the Kerala Panchayat Raj Act (13 of 1994)., 109. Removal of doubts, etc. - The Government shall have power, if any doubt arises with regard, to the interpretation or otherwise of any provision or if any difficulty arises in the, implementation of any provision, to clarify the doubt or to issue necessary direction for, removing the difficulty., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 118
Page 129 :
119, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX- A1, , (See rules 5(1)(b), 75(1), 87(1) and 93(1)), , APPLICATION FOR PERMIT/REGULARISATION, , …………………………………………………………. Panchayat, , 1. Name in capital letters, , :, , Applicant(s), , 2., , 3., , Address:, , (i) Permanent address of the owner, , :, , (ii) To which communications are to be sent, , :, , (i) Division of plot, , :, , Nature of development/construction:, (ii) New construction, , Owner(s), , (iii) Reconstruction, , (iv) Alteration /Addition/Extension, (v) Digging of well, , (vi) Change in occupancy, (vii) Demolition, 4., , (viii) Roof changing, Details of plot, , (i) Revenue Village, (ii) (a) Survey No, , :, , (b) Resurvey No, , (iii) Sub Division, , (iv) Taluk, , (v) District, , :, , :, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 119
Page 130 :
120, , KERALA PANCHAYAT BUILDING RULES 2019, (vi) Extent in Sq.m, , :, , (viii) Number and date of deed/ Document, , :, , (vii) Nature of ownership, , :, , (ix) Registrar's Office, , :, , (xi) Authorised number of the nearest building, , :, , (x) Ward No., , :, , (xii) Nearest Electric Post/Telecom Post number, , :, , 5. Whether the land, if any, contiguous to this plot, of the owner shown in the site plan (Rule 6(4)(a)(i)), , : Yes /No, , 6. Usage of surrounding plots in general, North, East, , :, , South, , :, , :, , West, , 7 .Whether Government or Quasi Government, 8. Details of the Construction, , :, , :, , (i) Details of Proposed Building(s), , Floors, , Basement, floor, , Building no. 1, Building no. 2, Occupancy:, Occupancy :, Height of the building Height of the building - ……………, …………… m, m, Built-up, Built-up, Area, Use, Use, Area, area, area, provided for, provided for, (Sq.m.), (Sq.m.) parking inside, parking, the building, inside the, (Sq.m.), building, (Sq.m.), , Ground, floor, , Total, Add separate sheet if required, duly signed by both the licensee and the Owner, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 120
Page 131 :
121, , KERALA PANCHAYAT BUILDING RULES 2019, (ii), , Details of Existing Building(s), , Floors, , Basement, floor, , Building no. 1, Building no. 2, Occupancy:, Occupancy:, Height of the building Height of the building - ……………, …………… m, m, Built-up, Built-up, Area, Use, Use, Area, area, area, provided for, provided for, (Sq.m.), (Sq.m.) parking inside, parking, the building, inside the, (Sq.m.), building, (Sq.m.), , Ground, floor, , Total, Add separate sheet if required, duly signed by both the licensee and the Owner, (iii) Total Built-up Area, , :, , (v) Total parking area provided inside the building(s), , :, , (iv) Total Covered Area, , (vi) Total Built-up Area for F.S.I., , 9. Basic KMBR Verification w.r.t. proposed plot, , Sl. No. Rule No., Description, 1, Access width to the plot, 2, Coverage, 3, Floor Space Index, , :, , :, , Required/permissible, , Provided, , 10. Basic KPBR Verification w.r.t. proposed building(s), (a) Building no. 1, Sl., No., 1, 2, 3, 4, , Rule No., , Description, , Required/permissible, , Provided, , Access width to the building (in, m), Minimum distance from the, abutting road/access to other, building(s) (in metre), No. of Four-wheeler parking, No. of Two-wheeler parking, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 121
Page 132 :
122, , KERALA PANCHAYAT BUILDING RULES 2019, 5, , No. of Parking for Differently, abled, No. of Parking for Visitors, Loading/unloading space (in sq., metre), Set Backs (in metre), Front, Side 1, Side 2, Rear, Exit Width (in metre), No. of Stair case(s), No. of Fire Escape Stair case(s), Rainwater storage capacity (in, litre), , 6, 7, 8, , 9, 10, 11, 12, , Add separate sheet if required, duly signed by both the licensee and the Owner, , 11. Provisions of Town Planning Schemes, if any, applicable to the construction, (I) Zoning, Sl., No., , Name of the TP, Scheme, , Stage, (Sanctioned/, Published), , Zone, , Permissibility of proposed, construction as per the scheme, , (ii) Road Widening, , Sl., No., , Name of, the TP, Scheme, , Stage, (Sanctioned, / Published), , Existing, Width of, road, (in, m), , Proposed, Width of, road, (in m), , Building, Line, (in m), , Set Back, Required, from, Existing, road, boundary, (in m), , Set back, provided, (in m), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 122
Page 133 :
123, , KERALA PANCHAYAT BUILDING RULES 2019, 12. Permissibility with respect to Kerala Conservation, of Paddy Land and Wet Land Act 2008 / KLU order 1967., (i) Type of land as per BTR, :, (ii) Type of land as per Data Bank, :, 13., , If the application is for regularisation,, , (i) Whether construction completed or not, , (ii) If not completed, the stage of construction, , 14. Details of permit/approved plan already obtained., 15., , 16., 17., , Details of fee paid:, , :, , :, , Application fee, , (i) Amount, , :, , Layout scrutiny fee, , (ii) No. and date of receipt, , Details of documents, plans, certificate, etc. enclosed., Details of NOC obtained., , SL ., no, , 18., , Required, , Whether enclosed or not, , Details of the NOC /, Clearances, , DECLARATION, , I,…………………………………………………………….………………hereby declare that the, measurements, specifications and other details mentioned above are correct, complete and true to, the best of my knowledge and belief and that I shall abide by the approved plan and the provisions, in the Act and Rules in undertaking the construction., Place:, Date:, , Signature of the applicant with name, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 123
Page 134 :
124, , KERALA PANCHAYAT BUILDING RULES 2019, 19., , CERTIFICATE, , Certified that the site plan is prepared after verification of ownership document and site and the, measurements shown are found to be correct., Signature:, , Place:, Date:, , 20., , Name:, , Reg.No.:, , Address:, , (Registered Institution, Architect,, Town Planner, Supervisor), , Engineer,, , CERTIFICATE, , Certified that the building plan is prepared in accordance with the provisions in the Kerala, Panchayat Building Rules 2019, Kerala Panchayat Raj Act, 1994 and the provisions contained in, the sanctioned Town Planning Schemes, if any., Place:, Date:, , Signature:, Name:, , Reg.No.:, , Address:, , (Registered Institution/Architect/, Engineer/Town Planner/Supervisor), 21., , UNDERTAKING, , I,… ..................................................................... hereby undertake that the building construction, and/or land development will be carried on/ being carried on/ was carried on as per the approved, plan and permit in accordance with the rules in force., Place:, Date:, , Signature:, Name:, , Reg.No.:, Address:, , (Registered Institution/, Architect/Engineer/Town Planner/ Supervisor), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 124
Page 135 :
125, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX- A2, , FORM OF APPLICATION FOR CONSTRUCTION IN PLOTS PARTS OF WHICH HAVE, BEEN SURRENDERED FREE OF COST FOR ROAD DEVELOPMENT, [See rule 62(1)], (To be submitted along with the application for permit), , ..…………………………………………………………. Panchayat, , 1., 2., , Name of applicant(s)(in capital letters), Address:, , (i) Permanent address of the applicant(s), , (ii) To which communications are to be sent, , 3. Details of land surrendered under Rule 62(1), , (b), , :, , :, , :, , :, , (i) Details of Master Plan / Detailed Town Planning Scheme / Interim Development Order in, force under the Kerala Town and Country Planning Act, 2016, as per rule 62(1), (a) Name of the Plan / scheme, :, Name of the Road development project, , (c), , Present stage of implementation, , (d) Zoning provisions, , :, , :, , (e) Other provisions, , (ii) (a) Name of project applicable as per Rule 62(1) :, (b) Implementing Agency, (Local Self Government Institution/, Development Authority/, Government Department/, Quasi Government Organisation/Institution/, Registered Residents Associations/, Social Welfare Organisation), , (iii), , (c) Present stage of implementation, , :, , :, , Details of land in sq. m, (Enclose sketch with all detailed measurements), (a) Total extent of land, , :, , :, , :, , (b) Extent of land required for implementation of, the scheme in total from the plot, :, (c) Land surrendered free of cost for the scheme :, , :, :, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 125
Page 136 :
126, , KERALA PANCHAYAT BUILDING RULES 2019, (d), , (iv), , :, , Name of the owner of the land so surrendered, , :, , Survey No./Re Survey No. of the surrendered land :, , (v), , (vi), 4., , Percentage of land surrendered, , Details of Relinquishment, (Enclose copies of relinquishment), , Applicability of special provisions, , Item, , Coverage, F.S.I., Set backs: Front, Side 1, Side 2, Rear, Height, Parking, , Required/permissible, as per general, provisions, , 5., , :, :, , :, , Required/permissible, as per special, provisions, , Provided, , Remarks of the, Special committee, , DECLARATION, , I,…………………………………………………………….………………hereby declare that the, measurements, specifications and other details mentioned above are correct, complete and true to, the best of my knowledge and belief and that I shall abide by the approved plan and the provisions, in the Act and Rules in undertaking the construction., Place:, Date:, , Signature of the applicant with name, , 6., , CERTIFICATE, , Certified that the site plan is prepared in accordance with the Kerala Panchayat Building Rules, 2019, Kerala Panchayat Raj Act 1994, provisions contained in the Master Plan / Detailed Town, Planning Scheme / Interim Development Order in force under the Kerala Town and Country, Planning Act 2016 and road development proposals of the implementing agency., Place:, Date:, , Signature:, Name:, , (seal), , Reg.No.:, Address:, (Registered Institution/ Architect/ Engineer/, Building Designer /Town Planner/ Supervisor), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 126
Page 137 :
127, , KERALA PANCHAYAT BUILDING RULES 2019, , APPENDIX –A3, , [See rule 5(1)(a)], , APPLICATION FORM FOR PERMIT FOR DEVELOPMENT/ REDEVELOPMENT OF, LAND, , To, , The Secretary,, Sir,, , ..…………………………………………………………. Panchayat, , I, intend, to, develop/, redevelop, the, land, in, Survey/Re, survey, Number………………………of, ............................................., Village, in, .................................................Taluk............................ owned by me. I forward herewith the site, plan, service plan and specification in duplicate duly signed by me and, by…………………….…………….(Name in Block letters of the registered Institution /Architect/, Building, Designer/, Engineer/, Town, Planner/, Supervisor), having, Register, No… ................................together with the required documents., I hereby undertake to abide by the provisions of the Kerala Panchayat Building Rules, 2019, in all respect., I request that the development/ redevelopment may be approved and development permit, may be granted to me., Signature…………..……………………, , Place:, Date:, , Name of owner……………………..., , (in Block letters), , Address…………………………….., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 127
Page 138 :
128, , KERALA PANCHAYAT BUILDING RULES 2019, , Appendix-A4, , (See rule 5(6)(2)), , APPLICATION FOR LAYOUT APPROVAL AND USAGE OF PLOT/CONCURRENCE, ………………………………………………………….District, , 1. Name in capital letters, , :, , Applicant(s), , 2., , Address:, , (i) Permanent address of the owner, , 3., , :, , (i) Division of plot, , :, , (iii) Reconstruction, , :, , (ii) New construction, , :, , (iv) Alteration /Addition/Extension, 4., , :, , (ii) To which communications are to be sent, , Nature of development/construction:, , :, , (v) Change in occupancy, , :, , Details of plot, , (i) Name of Local Self Government Institution, (ii) Revenue Village, (iii) (a) Survey No., , :, , :, , (iv) Sub Division, , (v) Taluk, , (vi) District, , (vii)Extent in Sq.m, , (ix) Ward No., , :, , :, , (b) Resurvey No., , (viii) Nature of ownership, , Owner(s), , :, , :, , :, , :, , :, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 128
Page 139 :
129, , KERALA PANCHAYAT BUILDING RULES 2019, (x) Authorised number of the nearest building, , :, , (xi) Nearest Electric Post/Telecom Post number, , :, , 5. Whether the land, if any, contiguous to this plot, of the owner shown in the site plan (Rule 6(4)(a)(i)), , : Yes /No, , 6. Usage of surrounding plots in general, North, East, , :, , South, West, , 7 .Whether Government or Quasi Government, 8. Details of the proposed construction, , :, , :, :, , :, , (i) Details of Proposed Building(s), , Floors, , Basement, floor, , Building no. 1, Building no. 2, Occupancy, Occupancy, Height of the building Height of the building - ……………, …………… m, m, Use, Built-up, Area, Use, Built-up, Area, area, provided for, area, provided for, (Sq.m.), parking, (Sq.m.) parking inside, inside the, the building, building, (Sq.m.), (Sq.m.), , Ground, floor, , Total, Add separate sheet if required, duly signed by both the licensee and the Owner, , (ii) Details of Existing Building(s), , Floors, , Building no. 1, Building no. 2, Occupancy, Occupancy, Height of the building Height of the building - ……………, …………… m, m, Use, Use, Built-up, Area, Built-up, Area, area, provided for, area, provided for, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 129
Page 140 :
130, , KERALA PANCHAYAT BUILDING RULES 2019, (Sq.m.), , Basement, floor, , (Sq.m.), , parking, inside the, building, (Sq.m.), , parking inside, the building, (Sq.m.), , Ground, floor, , Total, Add separate sheet if required, duly signed by both the licensee and the Owner, , (iii) Total Built-up Area, , (iv) Total parking area provided inside the building(s):, , :, , (v) Total Built-up Area for F.S.I., , 9. Basic KPBR Verification w.r.t. proposed plot, , Sl. No. Rule No., Description, 1, Access to the plot, 2, Coverage, 3, Floor Space Index, , Required/Permissible, , Provided, , 10. Basic KPBR Verification w.r.t. proposed building(s), (a) Building no. 1, Sl., No., 1, 2, 3, 4, 5, 6, 7, 8, , Rule No., , Description, Access to the building (in metre), Minimum distance from the, abutting road/access to other, building(s) (in metre), No. of Four-wheeler parking, No. of Two-wheeler parking, No. of Parking for Differently, abled, No. of Parking for Visitors, Loading/unloading space, (in sq. m), Set Backs (in m), Front, Side 1, Side 2, Rear, , Required/Permissible, , Provided, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 130
Page 141 :
131, , KERALA PANCHAYAT BUILDING RULES 2019, 9, 10, 11, 12, , Exit Width (in m), No. of Stair case(s), No. of Fire Escape Stair case(s), Rainwater storage capacity (in, litre), Add separate sheet if required, duly signed by both the licensee and the Owner, , 11. Provisions of Town Planning Schemes, if any, applicable to the construction, (i) Zoning, , Sl., No., , Name of the TP, Scheme, , Zone, , Stage, (Sanctioned/, Published), , Permissibility of proposed, construction as per the scheme, , (ii) Road Widening, , Sl., No., , Name of, the TP, Scheme, , Stage, (Sanctioned/, Published), , Existing, Width of, road(in, metre), , Proposed, Width of, road(in, metre), , 12. If the application is for regularisation,, , (i) Whether construction completed or not, , (ii) If not completed, the stage of construction, , 13. Details of permit/layout approval already obtained., 14., , Details of fee paid:, , (i) Amount, , Building, Line(in, metre), , Set Back, Required, Set back, from, provided, Existing, (in, road, metre), boundary(in, metre), , :, , :, , Application fee, , (ii) No. and date of receipt, , 15. Details of documents, plans, certificate, etc. enclosed., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 131
Page 142 :
132, , KERALA PANCHAYAT BUILDING RULES 2019, 16., , SL ., no, , Details of NOC / Clearances obtained., Required, , Whether enclosed or not, , Details of the NOC /, Clearances, , 17. Whether application for permit /regularisation is submitted to the Local Self Goverment, Institution: Yes/No, If Yes, file no. of the application in the Local Self Goverment Institution :, 18., , DECLARATION, , I,…………………………………………………………….………………hereby declare that the, measurements, specifications and other details mentioned above are correct, complete and true to, the best of my knowledge and belief and that I shall abide by the approved plan and the provisions, in the Act and Rules in undertaking the construction., Place:, Date:, 19., , Signature of the applicant with name, , CERTIFICATE, , Certified that the site plan is prepared after verification of ownership document and site and the, measurements shown are found to be correct., Signature:, Place:, Date:, , Reg.No.:, , Name:, , Address:, , (Registered Institution, Architect, Engineer,, Town Planner, Supervisor), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 132
Page 143 :
133, , KERALA PANCHAYAT BUILDING RULES 2019, , 20., , CERTIFICATE, , Certified that the building plan is prepared in accordance with the provisions in the Kerala, Panchayat Building Rules 2019, Kerala Panchayat Raj Act, 1994 and the provisions contained in, the sanctioned Town Planning Schemes, if any., Place:, Date:, , Signature:, Name:, , Reg.No.:, Address:, , (Registered Institution/Architect/, Engineer/Town Planner/Supervisor), , 21., , UNDERTAKING, , I,… ..................................................................... hereby undertake that the building construction, and/or land development will be carried on/ being carried on/ was carried on as per the approved, plan and permit in accordance with the rules in force., Place:, Date:, , Signature:, , Name:, , Reg.No.:, Address:, , (Registered Institution/Architect/Engineer/, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 133
Page 144 :
134, , KERALA PANCHAYAT BUILDING RULES 2019, , APPENDIX B1, [See rule 6(17)], , DEVELOPMENT PERMIT, , ……………………………………………………………….……………. Panchayat, , No……………….., , Dated………………, , Ref:- Application, dated……………..……..from, Smt……………………………..……………., , Sri/, , Permission is hereby granted for the development or redevelopment of land to the extent of, ....…..................…Ares/, hectares, comprised, in, Survey, No./Re, survey, No., ....................………………Village……………………………Taluk… ............................. District…, …………………for……………………………………… use (specify)subject to the following, conditions:(1), (2), (3), , (4), (5), , Place:, , Existing trees should be retained as far as possible and more number of trees planted in the, available space after development., , The permit is subject to the satisfaction of the provisions in the Kerala Conservation of, Paddy Land and Wet Land Act 2008 / KLU order 1967 and the permit issued thereunder., , Adequate safety measures shall be ensured for protection against damage to health, life, buildings and property of the inhabitants around, during and after development. The owner, and the developer shall be solely responsible for any such damages, , ..……………………………………………………………………, ……………………………………………………………………., , Date:, , Signature and name of Secretary, , (Seal), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 134
Page 145 :
135, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX B2, , [See rule 6(17)&9(4)], , SITE APPROVAL AND BUILDING PERMIT, , …………………………………………………………. Panchayat, , No………………………………, , Dated….………………, , Ref:- Application dated……………………….from Sri./Smt. ……………………., , Site approval and permission is granted for the construct/reconstruct/erection/re-erection/, addition/alteration of building/ hut/ digging of well/ ......…………………………(specify the, construction), in, building, No………………………or, near, the, building, No………………..............................in, Survey/Re, survey, No, ……………………………………………., Village, …………………………………Taluk………………………………………, District, ……………………………………………, for ........................................................... (specify, the occupancy) purpose subject to the conditions stated below:, (1) Adequate safety measures shall be ensured for protection against damage to health, life,, buildings and property of the workers and inhabitants around, during and after building, construction. The owner and the developer shall be solely responsible for any such damages., (2), , ………………………………………………………………………., , (4), , ……………………………………………………………………….., , (3), , ……………………………………………………………………….., , (a) Set backs (m) (minimum & average), Building 1 Front, , Rear Side, , Side - 1, , Side 2, , Building 2 Front, , Rear Side, , Side - 1, , Side 2, , Building 3 Front, , Rear Side, , Side - 1, , Side 2, , (b ) Plot Area (sq m) (c) FAR :, , Coverage :, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 135
Page 146 :
136, , KERALA PANCHAYAT BUILDING RULES 2019, (d) Details of proposed building, , Floors, , Basement, floor, , Building no. 1, Building no. 2, Occupancy, Occupancy, Height of the building Height of the building - ……………, …………… m, m, Built-up, Built-up, Area, Use, Use, Area, area, area, provided for, provided for, (Sq.m.), (Sq.m.) parking inside, parking, the building, inside the, (Sq.m.), building, (Sq.m.), , Ground, floor, , Total, , (Seal), , Signature and name of Secretary, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 136
Page 147 :
137, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX C, , [See rule 10 (7)], , Concurrence / Usage of Plot, , No…………………………………………., Dated….……………….……, , Name, , of, , the, , Local, , Self, , Government, , Ref:- (1), Application dated… ................................ from Sri./Smt, ……………………………………………….….…, , Institution:, , (3) Permit No:……………………………………………………., Dated………………………………………………..….., , Concurrence is granted for proceeding with the construction above the ground level as per, the, permit, cited, in, ref, (2), for………………………………………………………………………………..(specify, the, construction) in building No: ................................................................................. or near the building, No…………..……, in, Survey, No/Re, Survey, No .................................................. in, ……………………………………..……Village, in, ......................Taluk, in, ……………………………, District ........................................................................... for, ………………………......……… (specify the occupancy) purpose subject to the conditions stated, below:, (i), , ………………………………………………………………………., , (ii), , ………………………………………………………………………., , (iv), , ……………………………………………………………………….., , (iii), , ……………………………………………………………………….., , (1) Built-up area of the building is as follows:Basement, Ground Floor, First Floor, ……………………………, …………………………….., (2) FAR (3) Access width (m) Place:, Date:, , Coverage -, , (Seal), , Signature and name of Secretary, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 137
Page 148 :
138, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX - D, , [See Rule 17(5) (d)], , NOTICE REGARDING THE INTENTION TO START WORK, , I hereby give notice that I intend to start the development or redevelopment of land and/or, construction or reconstruction or addition or alteration of building on………………………as per, permit No……………………………………………dated……………………………………, , Place:, Date:, , Signature, , Name and address of owner, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 138
Page 149 :
139, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX E1, , [See rules 17(5)(e),20(1)&88 (1)], , COMPLETION CERTIFICATE BY THE OWNER, CERTIFICATE, , Certified that the development or redevelopment of land and/or construction, or, reconstruction or addition or alteration of building / erection of Telecommunication tower or, pole structure has been completed on...................................... as per the approved plan and permit, number . . . . . . . . . . . .. . .. . .dated . . . . . . . . . . . . . . . ., Place:, Date:, , Signature, , Name and address of owner., , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 139
Page 150 :
140, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX E2, , [See rules 17(5)(e)&20 (4)], , PARTIAL COMPLETION CERTIFICATE BY THE OWNER, CERTIFICATE, , Certified that the development or redevelopment of land and/or construction, or, reconstruction or addition or alteration of building(s) / erection of telecommunication tower or, pole structure have been partly completed on....................................... as in the approved plan and, permit number . . . . . . . . . . . .. . .. . .dated . . . . . . . . . . . . . . . ., , Also certified that the above partially completed building(s) comply in all respects with the, provisions contained in the Kerala Panchayat Building Rules, 2019 and other applicable statutes, and the work has been carried out as per the drawings signed and attached., Place:, Date:, , Signature, , Name and address of owner, , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 140
Page 151 :
141, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX E3, , [See rule 20(1)&88(1)], , COMPLETION CERTIFICATE BY INSTITUTION, ARCHITECT, ENGINEER, ETC., CERTIFICATE, , Certified that the development or redevelopment of land or construction or reconstruction or, addition or alteration of building(s)/ erection of telecommunication tower or pole structure or work, has been supervised by me and has been completed on ...................................................... as per the, approved plan and permit No. . . . . .. . . .. . .………. dated……………………, , Place:, Date:, , (seal), , Name:, , Signature:, , Register No:, , (Registered Institution/ Architect/ Engineer/, Building Designer /Town Planner/ Supervisor), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 141
Page 152 :
142, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX E4, , [See rule 20 (4)], , PARTIAL COMPLETION CERTIFICATE BY INSTITUTION, ARCHITECT,, ENGINEER, ETC., CERTIFICATE, Certified that the development or redevelopment of land and/or construction or reconstruction or, addition or alteration of building(s)/erection of telecommunication tower or pole structure or work, has been supervised by me and has been partially completed on ................................................. as in, the approved plan and permit No. . . . . .. . . .. . .………. dated……………………, Also certified that the above partially completed building(s) comply in all respects with the, provisions contained in the Kerala Panchayat Building Rules, 2019 and other applicable statutes, and the work has been carried out as per the drawings signed and attached., Signature:, Place:, Date:, , Name:, , Register No:, , (Registered Institution/ Architect/ Engineer/, Building Designer /Town Planner/ Supervisor), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 142
Page 153 :
143, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX F1, , [See rule 17(5)(f)&20 (2)], , DEVELOPMENT CERTIFICATE, , ………………………………………………………………………… Panchayat, Certified that the development or redevelopment of land under the Permit, No……………..dated…………………issued to Sri ..................................................................... and, supervised by ..............................................has been inspected by me and that the work executed is, in accordance with the permit and that the land is now fit for building construction., Place:, Date:, , Signature and name of Secretary, (Seal), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 143
Page 154 :
144, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX F2, , [See rule 17(5) (f), 20 (3) and 88 (2)], , OCCUPANCY CERTIFICATE OR USE CERTIFICATE, , ………………………………………………………………………… Panchayat, Reference:, Completion certificate / Partial Completion certificate submitted by the, applicant(Name) …………………................ dated........................... and the licensee (Name & Reg., No.) .................................... dated ........................, Certified that the construction or reconstruction or addition or alteration of building or, erection of telecommunication tower or pole structure or work under the permit No……….……, …………………………dated… ................................... issued, to…….……………………………………………and, supervised, by… ......................................................................................... has been inspected by me and that the, work executed is in accordance with the permit and the building/ tower or pole structure is now fit, for occupation/ use., Place:, Date:, , Signature of the Secretary, (Seal), , FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 144
Page 155 :
145, , KERALA PANCHAYAT BUILDING RULES 2019, APPENDIX G1, [See rule 95 (3)], , ………………………………………………………………………… Panchayat, Abstract, , BUILDING CONSTRUCTION/ LAND DEVELOPMENT WITHOUT PERMISSION OR, DEVIATION FROM APPROVED PLAN - REGULARISATION GRANTED - ORDERS, ISSUED, , Ref:- Application dated…………………….…from Sri./Smt………………………………, No. ....................................................................................Dated, ………………………………., ORDER, , Whereas the application submitted by Sri/Smt ......................................................................... for, regularisation of a construction or reconstruction or alteration or addition of, ……………………….. (specify the use)building / hut / shed / wall / erection of telecommunication, tower or pole structure / digging of well / conversion of roof / conversion or erection of shutter or, door/ land development / any other work (………………..………specify)commenced/ being, carried on / completed in, the, land, comprised, in, Sy.No/Resurvey No., ……………………..............., Village......................…………………………Taluk……………………………………… District, ……………………………………………in, the, building, bearing, No……………………………………… / near the, building bearing No… ................... has, been duly considered by me and decision to regularise the same has been communicated in letter, No.…………………………. dated…………………………, And whereas the said Sri/Smt………………………………………………has remitted, Rs…………………as compounding fee............................................................................ vide receipt, No………………………..… dated………………………………………….and has complied with, the directions/conditions stipulated in the letter dated……………………………….., , Now, therefore, in exercise of the powers conferred by Rule 95(3) of Kerala Panchayat Building, Rules, 2019, I, …………………………………., (name), Secretary of, the ............................................................................ Panchayat hereby order that the said person has, been absolved from the liabilities in respect of the construction or reconstruction or alteration or, addition of ......................................................... (specify the use) building/ hut/ shed / wall / erection, of telecommunication tower or pole structure / digging of well/ conversion of roof / conversion or, erection of shutter or door / land development / any other work ( ......................................specify)and, that the construction or reconstruction or alteration or addition of ........................................ (specify, the use) building / hut / shed / wall / erection of telecommunication tower or pole structure /, FEDERATION OF ENGINEERING EMPLOYEES IN LOCAL ADMINISTRATION (FEELA), , 145
Page 156 :
146, , digging of well / conversion of roof / conversion or erection of shutter or door/ land, development / any other work ( ............. specify)has been regularised., Built-up area of the regularized part of the building is as, follows:- Basement Floor :, Ground Floor :, First Floor, , :, , ………………, , :, , ………………, Total, , :, :, , [Continuation of the work, if any, as per the drawings submitted shall be subject to permit, No:………….............. dated ………………………. being issued herewith.](strike off if not, applicable), Plans and details of the construction regularised are appended with this order., , (Seal), , Signature of Secretary
Page 157 :
1, 2, 3, 4, 5, , Area of land survey No./, Resurvey No., Village, Taluk, etc, , Details of area of building, existing/ regularised, , Details of amount etc. of, application fee paid, , Date of application with, date of receipt, , Name and address of, applicant/ owner, , Sl No, , 6, , Date and No. of intimation, permitting regularization, with date of, despatch, , 8, 9, , Remarks, , Details of regularization, order issued, , 7, , Amount, date etc, of, regularization fee paid, , 147, , APPENDIX –G2, , [See rule 95 (3)], , REGISTER FOR REGULARISED CONSTRUCTIONS, , ………………… Municipal Corporation / Municipal Council / Town Panchayat, , 10
Page 158 :
148, , APPENDIX –H1-A, [See rule 99(1)], , GOVERNMENT OF KERALA, , Application for Registration as Architect/Engineer/Town Planner/Supervisor etc. under, the Kerala Panchayat Building Rules, 2019, Affix Passport, Size photo, , 1., , Name of Applicant, , 2. Permanent Address, , 3. Address to which communications, are to be sent, , 4. Educational Qualifications, (Attested copies should be enclosed), 5. Age and Date of Birth, (with proof), , :, , :, , :, :, :, , 6., , Sex, , :, , 8, , References of previous licenses, if any, , :, , 7. Experience (Attested copies should be enclosed) :, , 9, , Details of show cause notices received/, cancellation of licenses, etc if any, , 10 Whether employed in the service of Government :, or Quasi-Government or Government owned, Corporation or Board, Authority or Government, Companies or Banks or not (If so employed, give particulars), , :, , (One extra copy of the photo, should be separately, enclosed for issuing identity, card)
Page 159 :
149, , 11 Whether retired from service or not, (If retired, give details), (Proof to be attached), , :, , 12. Specimen Signature, , :, , (i), , (ii), , (iii), DECLARATION, , I,… ............................................................................................................................. hereby declare, that the details furnished above are correct, complete and true to the best of my knowledge and, belief., , Signature:……………………………………, Place:, Date:, , Name:………………………….……
Page 160 :
150, , APPENDIX –H1-B, [See rule 99(1)], , GOVERNMENT OF KERALA, , Application for Registration as Institution (Architecture) / Institution (Civil Engineering), under the Kerala Panchayat Building Rules, 2019, 1., , 2., , Name of Institution, , Permanent Address, , :, , 3., , Address to which communications, are to be sent, , :, , 4., , The University in Kerala to which the institution, is affiliated and the date of affiliation(with proof) :, , 5., , :, , Whether the registration is required for, Institution (Architecture) /, Institution (Civil Engineering), , :, , 6, , References of previous licenses, if any, , :, , 7, , Details of show cause notices received/, cancellation of licenses, etc if any, , :, , (Attested copies of document showing valid, registration/recognition of Bachelor’s degree, course in Architecture from Council of, Architecture or that in Civil Engineering from, AICTE, as the case may be, should be enclosed)
Page 161 :
151, , 8., , Name and Specimen Signature of the Head of Department of Architecture / Civil, Engineering, as the case may be:, Name:………………………………………, , Signature: (i), (ii), , (iii)(iii), DECLARATION, , I, ............................................................................................................................................ hereby declare, that the details furnished above are correct, complete and true to the best of my knowledge and, belief. Any change of person in the capacity of the Head of Department of Architecture or Civil, Engineering, as the case may be, will be officially intimated to the registering authority with, name and specimen signature of such person., Signature: …………………………………, , Name:………………………………………, , Designation:…………………………………, , (of the Principal / Head of the Institution), , (Office seal), Place:, Date:
Page 162 :
152, , APPENDIX –H2, (See rule 81(11)& 100), QUALIFICATION AND FUNCTION OF ARCHITECT, ENGINEER, ETC., Category, Qualifications, Function, (1), (2), (3), Institution, Valid, registration, / (i), To sign plans, drawings and, (Architecture), recognition, of, specifications in connection with, Bachelor’s degree in, development permit for areas upto, Architecture, in the, the extent of one hectare., institution, from the, (ii), Council of Architecture, To, issue, certificates, of, supervision in connection with, and, development permit for areas up, to the extent of one hectare, affiliation, of, the, pertaining to road work, water, institution to a university, supply drainage, sewerage and, in the state, light installations., (iii), To prepare and sign all plans and, information connected with the, building permit., (iv), (iv), To prepare and sign structural, design and calculations, for, building(s) upto 500 sq.m. and, upto 3 storeys or 11 metres, (v), height., , Institution, (Civil, Engineering), , Valid, registration, /, recognition, of, Bachelor’s degree in, Civil Engineering in the, institution from AICTE, and, , affiliation, of, the, institution to a university, in the state, , (i), , (ii), , To issue certificates of, supervision and completion for all, types of buildings., To sign plans, drawings and, specifications in connection with, development permit for area upto, the extent of one hectare., To issue certificates of supervision, in connection with development, permit for areas upto the extent of, one hectare pertaining to road work,, water supply, drainage, sewerage, and light installations., , (iii) To prepare and sign all plans, information connected with building, permit.
Page 163 :
153, , (iv) To prepare and sign structural, designs and calculations connected, with all types of buildings other than, high rise buildings, (v) To issue certificates of, supervision and completion for all, types of buildings., Architect, , Building, Designer-A, , Registration with the, Council of Architecture,, India as prescribed under, Architect’s Act 1972, (Central Act 20 of 1972), , (i), , To sign plans, drawings and, specifications in connection with, development permit for areas upto, the extent of one hectare., , (ii), , To issue certificates of supervision, in connection with development, permit for areas up to the extent of, one hectare pertaining to road work,, water supply drainage, sewerage and, light installations., , (iii), , To prepare and sign all plans and, information connected with the, building permit., , (iv), , To prepare and sign structural, design, and, calculations,, for, buildings upto 500 sq.m. and upto 3, storeys, or 11 metres height., , (v), , To issue certificate of supervision, and completion for all buildings., , (i), , Associated membership, of the Indian Institute of, Architects; or, , (i), , To sign plans, drawings and, specifications in connection with, development permit for areas, upto the extent of one hectare., , (ii), , Any Degree or Diploma, required for membership, of the Indian Institute of, Architects; or, , (ii), , To, issue, certificates, of, supervision in connection with, development permit for areas up, to the extent of one hectare, pertaining to road work, water
Page 164 :
154, , supply drainage, sewerage and, light installations., (iii), (iv), , Any of the qualifications, included in the schedule, to Architects Act, 1972;, or, Degree in Architectural, Engineering, , (iii), , To prepare and sign all plans and, information connected with the, building permit., , (iv), , To prepare and sign structural, design and calculations, for, building upto 500 sq.m. and, upto 3 storeys, or 11 metres, height, To, issue, certificate, of, supervision and completion for, all buildings., To sign plans, drawings and, specifications in connection with, development permit for area upto, the extent of 0.5 hectares., , (v), Building, Designer-B, , Any person retired from, Government or Quasi, Government service from, a post not below the rank, of Assistant Architect and, not, possessing, the, qualifications, for, registration as Architect, shall be eligible for, registration as Building, Designer- B., , (i), , (ii), , (iii), , Engineer A, , (i), , Corporate, membership, (Civil) of the Institution, of Engineers; or, , To, issue, certificates, of, supervision in connection with, development permit for areas up, to the extent of 0.5 hectares, pertaining to road work, water, supply, drainage, sewerage and, light installation., To prepare and sign all plans and, information connected with, buildings up to 1000 sq.metres in, area or upto 4 floors and stair, cabin or 14.5 metres. height, excluding the height of the stair, cabin., , (iv), , To, issue, certificate, of, supervision and completion for, all buildings coming under item, (iii) above., , (i), , To sign plans, drawings and, specifications in connection, with development permit for, area upto the extent of one, hectare.
Page 165 :
155, , (ii), , Any degree or equivalent, qualification in Civil, Engineering which is, required for the corporate, membership, of, the, Institution of Engineers;, or, , (ii), , To, issue, certificates, of, supervision in connection with, development permit for areas, upto the extent of one hectare, pertaining to road work, water, supply, drainage, sewerage and, light installations., , (iii), , Any person having valid (iii), registration as Engineer, under, the, Kerala, Municipal Building Rules,, 1999 shall be eligible for, registration as EngineerA., (iv), , To prepare and sign all plans, information connected with, building permit., , (v), Structural, Engineer, , Engineer B, , (i), , Post Graduate in, Structural Engineering, from a recognized, institution, Any person retired from, Government or Quasi, government service from, a post not below the rank, of, Assistant, Engineer/Assistant Town, Planner, and, not, possessing, the, qualifications, for, registration as Engineer-A, shall be eligible for, registration as EngineerB., , (i), (ii), (i), , (ii), , To prepare and sign structural, designs, and, calculations, connected with all types of, buildings other than high rise, buildings, To, issue, certificates, of, supervision and completion for, all types of buildings., To sign all structural drawings, To issue certificate with respect, to the structural stability of the, building, To sign plans, drawings and, specifications in connection with, development permit for areas, upto the extent of 0.5 hectare., To, issue, certificates, of, supervision in connection with, development permit for an area, upto the extent of 0.5 hectare, pertaining to road work, water, supply, drainage, sewerage and, light installations.
Page 166 :
156, , (iii) To prepare and sign all plans,, information connected with, building permit for buildings, upto 1000 sq.metres in area and, upto 4 floor and stair cabin and, 14.5 metres height, excluding, height of stair cabin., (iv) To issue certificates of, supervision and completion for, buildings coming under item (iii), above., Town Planner, A, , Town Planner, B, , (i), , Associate membership of, the, Institute of Town, Planner; or, , (i), , To sign plans, drawings and, specifications in connection with, development permit of all area., , (ii), , Any degree or diploma in, Town, and, Country, Planning which, is, required for associate, membership, of, the, Institute, of, Town, Planners., , (ii), , To issue certificate of, supervision for development, permit of all areas., , Any person retired from, Government or Quasi, Government service from, a post not below the rank, of Assistant, Town, Planner, and, not, possessing, the, qualifications, for, registration, as Town, Planner-A shall, be, eligible for registration as, Town Planner- B, , (i), , To sign plans, drawings and, specifications in connection, with, development permit for, an area up to one hectare, , (ii), , To, issue, certificate, of, supervision for development, permit for an area up to 1, hectare.
Page 167 :
157, , Supervisor, Senior, , (i), , (ii), , Diploma, in, Civil, Engineering and having 6, years’, experience, as, supervisor-A, or, , (i), , others having 10 years’, experience as supervisorA., , (ii), , Supervisor A, , (i), , To prepare and sign building, plans and other specifications, connected with buildings upto, total built up area 1000 sq.m., and upto four floors and stair, cabin and 14.5 metres height,, excluding the height of stair, cabin., , To, issue, certificates, of, supervision and completion for, buildings coming under item (i), above., , Diploma, in, Civil (i), Engineering/Architecture, and having completed 4, years’, experience, as, supervisor-B; or, Any person having eight, years’, experience, as, supervisor B; or, , To prepare and sign building, plans and other specifications, connected with buildings upto, total built up area 750 sq.m., andupto three floors and stair, cabin and 11metres height,, excluding the height of stair, cabin., , (iii) Any person having valid (ii), registration as Supervisor, (Special) under Kerala, Panchayat, Building, Rules, 2011; or, (iv) Any person retired from, Government or Quasi Government service from, a post not below the rank, of first grade Overseer, (Civil) or first grade, Draftsman (Civil) or first, grade Building Inspector, or first grade Town, Planning Surveyor having, completed 8 years in, service in any of those, post, shall be eligible for, registration as Supervisor, A., , To, issue, certificates, of, supervision and completion for, all types of buildings coming, under (i) above., , (ii)
Page 168 :
158, , Note:-For counting experience, continuous practice as supervisor, under Kerala Municipality Building Rules, 1999 shall also be taken, into account., Supervisor B, , (i), , Three, years (i), Architectural, Assistantship with two, years’ experience under, an Architect or Engineer;, or, (ii) Diploma, in, Civil (ii), Engineering/Architecture, with, two, years’, experience under an, Architect or Engineer; or, (iii) Draftsman, in, Civil, Engineering, from, Industrial, Training, Institute with five years’, experience under an, Architect or Engineer; or, (iv) K.G.C.E., in, Civil, Engineering, Draftsmanship, survey, with, Five years’, experience under an, Architect or Engineer; or, (v) Certificate in Building, Technology approved by, Government;, with, 10years’, experience, under an Architect or, Engineer;or, (va) Any, qualification, equivalent to that in item, (iii) with five years’, experience or that in, item (v) with ten years’, experience, under an, Architect or Engineer;or, (vi) Any person having valid, license as Supervisor, under Kerala Panchayat, Building Rules, 2011 is, eligible for registration, as Supervisor-B., , To prepare and sign plans and other, specifications, connected, with, buildings upto an area 300sq.m. and, upto two floors and stair cabin and, 7.5 metres height, excluding the, height of stair cabin, To issue certificates of supervision, and completion for all types of, buildings coming under (i) above
Page 169 :
159, , Note –, , A person registered under the Architects Act, 1972 as Architect shall be, deemed to be registered under this Rule., A person registered as Chartered Engineer with the Institution of Engineers, (India) shall deemed to be registered under these rules., A Structural Engineer qualified from a recognised university shall deemed, to be registered under these rules., A person registered as a corporate member (Assosiate / Fellow) of the, Institute of Town Planners (India) shall be deemed to be registered under, these rules.
Page 170 :
160, , APPENDIX –H3, [See rule 99 (4)], , CERTIFICATE OF REGISTRATION, , This, is, to, certify, that, ………………………………, Sri/Smt, ………………………………….………… (state the name and full address) has been registered, as ………………………………………………………………….(state the category) under the, provisions of the Kerala Panchayat Building Rules, 2019, , Place:, Date:, , Signature of, Registering Authority with name, (Seal)
Page 171 :
161, , APPENDIX-I, , [See rule 5(4)(Note ii)], , .....................………………………………………………… Panchayat, , DETAILS REGARDING APPLICATIONS FOR RENOVATION WITHOUT, INVOLVING ADDITIONAL BUILT-UP AREA OR STRUCTURAL ALTERATIONS OF, EXISTING BUILDINGS FOR RELIGIOUS PURPOSE OR PLACES OF WORSHIP, (To be submitted by the applicant to the Secretary in triplicate), , 1. Name of Applicant, , :, , 2. Address, , :, , 4. Extend of land, , :, , 3. Village and Survey Number, 5. Details of Renovation works, 6. Nature of ownership, , 7. Built-up area of existing building(s), Sl.No., , :, , :, , :, , Floor level, (Basement/First/Second. ....... etc), , Built-up area in sq.m, , 8. Certificate, Certified that the works for the above specified building (s) involved only renovation, works without any structural alterations or addition in the existing built-up area., (Signature), , Place:, Date:, , Name and address of the owner
Page 172 :
162, , For Office Purpose:, , 9. Forwarded to District Collector along with verified drawings and other relevant details, if, any., File/Application No:, , Date of receipt of application :, (office seal), , (Signature of Secretary), , 10. Acknowledgement of the receipt from District Collector, (Signature), , Place:, , Name and designation of the authorized signatory, , Date:, , 11. Action taken by the Secretary:
Page 173 :
163, , APPENDIX – J1, [See rule 6(3)], , CERTIFICATE, , (To be recorded in the drawings), Certified that:, (i), , (ii), , (iii), , the plot boundaries, measurements and other details shown in the site plan are correct, and, the drawings are in conformity with the provisions of the Master Plan/Detailed Town, Planning Scheme/ Interim Development Order as applicable under the Kerala Town, and Country Planning Act 2016., , the drawings are in conformity with the provisions of the Kerala Panchayat Building, Rules, 2019 and other applicable statutes., , Name:, , Reg.No.:, Address:, , (Registered Institution/, Architect/Engineer/Town Planner/ Supervisor), , (Signature )
Page 174 :
164, , APPENDIX – J2, [See rule 9(2)], , CERTIFICATE, , (To be recorded in the drawings), Certified that:, (i), , (ii), (iii), , (iv), , the document(s) in support of the ownership of the plot has/have been verified and, that the applicant (s) has/have every right of construction in this plot;, the plot boundaries, measurements and other details shown in the site plan have been, verified at site and found correct and, the drawings are in conformity with the provisions of the Master Plan/Detailed Town, Planning Scheme/ Interim Development Order as applicable under the Kerala Town, and Country Planning Act 2016., , the drawings are in conformity with the provisions of the Kerala Panchayat Building, Rules, 2019 and other applicable statutes., , (Signature ), Secretary, , ..................................………………………………………………… Panchayat, Office Seal
Page 175 :
165, , Appendix (K)(a), [See rule 5 (5)(2)], Approval forms for KSECBC, Form 1, Application for seeking Building Permit in respect of erection/re-erection/making alteration of, KSECBC Compliant Building., , To, The Secretary,, ..................................………………………………………………… Panchayat, Subject: Application for erection of KSECBC compliant Building in Survey/Re Survey No: --------------- Block No ----------------- of ---------------------------- village in ----------------------------------- Panchayat, Sir,, , I/we the undersigned hereby give you notice of my intention to erect / re- erect / alter, , KSECBC Compliant Building in plot under Survey/ Re Survey No: ----------- Block No of, , -------------- village in ---------- Panchayat and request for issue of building permit for the, construction of the building., , The following documents are enclosed., (i), , (ii), , (iii), , Undertaking by owner for construction of KSECBC compliant building;, , Construction Documents and Compliance Forms together with check-lists, , incorporating the installation of Energy Conservation Measures specified in the, aforesaid rules;, , Compliance Forms together with check-lists duly verified by Sri ------------- Regd., , Number ----------------- KSECBC licensed engineer/ BEE certified building energy, auditor and a certificate in Form II duly signed by him under his seal in this regard is, enclosed., , Yours faithfully,, (Name of the owner), Address---------------Tel.No/Mobile No----------------
Page 176 :
166, , Appendix (K)(b), [See rule 5 (5)(2)], Form IA, [Undertaking by owner for construction of ECBC compliant building], I am the owner of the aforesaid in plot under Survey/Re Survey No --------- Block -------- of -----, , -------- village in -------------------Panchayat. And the building on completion of construction shall, , have a connected load/contract demand of 100kW/120kVA or greater and is proposed to be, , constructed as KSECBC compliant building and shall be used or intended to be used for, commercial purposes., , The proposed building accordingly attracts the provisions of Kerala State Energy Conservation, Building Code 2017., , I/we undertake that the aforesaid building shall be constructed in accordance with the bye-laws, , of the Panchayat Authority and the provisions of KSECBC, 2017. In case any deviation is, , noticed during the construction of the Building, I/We shall indemnify the loss to the Authority, having jurisdiction., , I/we further undertake that the information supplied in the enclosed drawings and application is, , accurate to the best of my knowledge, and if any of the information supplied is found to be, incorrect and such information result in loss to the Central or the State Government or any other, authority under them, I/we undertake to indemnify such loss., Signature, (Name of the owner), Address…………….., Mobile No/Tel No…………
Page 177 :
167, , Appendix (K)(c), [See rule 5 (5)(2)], Form II, [Certificate from KSECBC licensed engineer /BEE certified building energy auditor to be, enclosed with the application for Building Permit for KSECBC compliant building], Certificate, I am Kerala State Energy Conservation Building Code (KSECBC) certified professional/, BEE certified building energy auditor having registration No/ ------------ under the Energy, Conservation Act 2001 and am / are authorized to scrutinize and verify the design of, KSECBC Compliant Building. I certify that –, , (a) I have scrutinized the construction documents duly signed by the owner/design, professional showing all the pertinent data and features of the building, equipment, and systems in sufficient details covering Building Envelope, HVAC, Service hot, water, Lighting and Electrical power in accordance with Panchayat Bye-laws and, with the KSECBC, in respect of building proposed to be constructed on plot under, Survey/Re Survey No: --------- Block No ------ of village in ----------------- Panchayat., (b) I have scrutinized the compliance forms together with the check- lists to ensure, compliance with the KSECBC., (c) The requisite documents incorporating the energy conservation measures have been, duly inspected by the undersigned., (d) The Energy Performance Index Ratio of the building design as per construction, documents at the design stage is equal to or less than one and is therefore in, compliance with the KSECBC., (e) It is certified that all the required scrutiny and verification on the documents, submitted have been carried out diligently and truthfully and all reasonable, professional skill, care and diligence have been taken in scrutinizing and verifying the, drawings of the buildings and compliance forms together with check-lists covering, the various components of the KSECBC., (f) The contents of all the documents submitted along with the application are a true, representation of the facts and nothing has been concealed., (g) There is no objection for issue of Building Permit in respect of the aforesaid proposed, Building in so far as requirements of KSECBC are concerned., Signature., Name of the KSECBC certified Licensed Engineer/, BEECertified building energy auditor, Registration No/SEAL., Date.
Page 178 :
168, , Appendix (K)(d), [See rule 17(19)], Form III, To, The Secretary,, -------------- Panchayat, , Sir,, , Notice of completion, , Subject: Erection of Kerala State Energy Conservation Building Code (KSECBC), Compliant Building in plot under Survey/Re Survey No:------------ Block No-----------------------of -------------- village in ------------------- Panchayat notice for completion of, works., , I / we hereby give notice that the erection of the building on Plot no., Block No., Scheme, Street, Name of the town/city, including execution and, implementation of the energy conservation measures have been completed in accordance with, the plans sanctioned vide your office communication No........ dated..........The following, documents are enclosed: (i), , A certificate of inspection on completion of the aforesaid building from, , Sri, KSECBC Licensed Engineer/BEE certified building energy auditor vide, Panchayat Authority Order No, dated, is enclosed. The building is fit for, use for which it has been erected/re-erected/constructed., It is requested that permission to occupy or use the aforesaid building may be granted., Yours faithfully,, , Signature..............., , Name of the owner, Plot no., , Block no., Address
Page 179 :
169, , APPENDIX - L, [See rule 5(4)], , SELF DECLARATION FORM, I do hereby declare that all the measurements mentioned in the civil plan are correct, and, complete., , I also hereby declare that all the required fire protection arrangements as listed in the National, building code are installed in the building and are ready for inspection and testing., , (Signature), , (Signature ), , Name of Owner., , Name:, , Reg.No.:, Address:, , (Registered Institution/ Architect/Engineer/, Town Planner/ Supervisor), , Name and address of the applicant, , :, , Occupancy of the building, , :, , Village, , :, , Survey Number, , Panchayat/Municipality, , I/We do hereby affirm that,, , AFFIDAVIT, , :, , :, , 1. the materials proposed to be used or installed for the construction of the building will be, as per required fire resistant rating in NBC of India – 2005, Part IV Annexure C, 2. all the proposed installations and power supply fixed for the proposed building will be as, per NBC of India 2005 Part IV Annexure C
Page 180 :
170, , 3. all the proposed Air conditioning, Smoke Management, Ventilation and staircase, Pressurization systems for the building, if installed, will be as per NBC of India Part IV, Annexure C, 4. all the proposed lightning protection installations for the building will be as per NBC of, India 2005 Part IV Annexure C, 5. the proposed gas bank for the building, supply lines and other fitting associated with it, if, installed will be as per NBC of India 2005 Part IV Annexure C, , Place:, Date:, , Signature of Applicant, Name:, , Note: If on any subsequent inspection the fire protection arrangements are found to be, ineffective, the owner of the building shall be liable to pay fine @ Rs.100 per sq. meter build up, area, not exceeding Rs.1,00,000/- in total.
Page 181 :
171, , Appendix M, See rule 3(5), , CRITERIA FOR CONSIDERING AN APPLICATION FOR EXEMPTION, , Application Fees:The applicants seeking exemption under this rule shall apply in writing to the, Secretary in form in Appendix N along with challan receipt remitting the application fee in the, Government treasury as detailed below., i), , ii), iii), iv), v), , Single family residential building of built up area up to 100 sqm …. No application, fee, Single family residential building of built up area up to 100 -300 sqm - Rs 1000, All other buildings with built up area up to 100 sqm - Rs 2000, All other buildings with built up area exceeding 100 sqm but up to 1000 sqm, …Rs10000, All other buildings with built up area exceeding 1000 sqm - Rs 20000, , Technical remarks: The Secretary shall submit the applications to the Chief Town Planner and, Chief Town Planner shall submit the application to the Government with technical remarks for, consideration., Rules exempted: The following occupancies / rules will not be considered for exemption, 1 Occupancy group not, considered for exemption, from these rules., 2 Rules not considered for, exemption from these rules, , Group G2- Industrial II, Group I-Hazardous ,Group J –, Multiplex Complex,, , Rules under chapter II and III, R26 (3) ( provision of, set back at ground itself), R 27- FSI, R 28 ( Access), R, 30 (lay out approval),R 31 (land sub division and plot, development), R 35 (2)(1) ( Fire escape stair case), ,R, 36 (Travel distance to emergency exits),R -40 (Lift/, Escalator), R 41 (1) ( lighting and ventilation),R 41(7)light and ventilation conformity with ECBC, provisions, R 42 (Provisions for differently abled,, Elderly and children), Rules under chapter X, (Construction in plots part of which have been, surrendered free of cost for road development), Rules, under chapter XIII ( Special provisions for certain, constructions), Rules under chapter XIV (Wells,, Rainwater harvesting),Rules under chapter XV (Solar, assisted water heating /lighting system), Rules under, chapter XVI ( waste disposal), Rules under chapter, XVII ( safety provisions for high rise buildings), Rules, under chapter XVIII( Telecommunication towers) and, Rules under chapter XIX,XX.
Page 182 :
172, , Criteria and Fee for exemption, , The appeal application will be considered for exemption from the rules based on the criteria, stipulated in table given below. The fee for exemption from various rules mentioned in the table, will be cumulative and total fee will be calculated by summing of the exemptions fees, individually for each rules as per the fee stipulated against each rules. However the exemption, fee for Single family residential building & commercial building having built up area up to 100, sqm is limited to Rs 5000/- and exemption fee for Single family residential building having, built up area above 100 upto 300 sqm is limited to Rs 20000/-., 1, , Rules/Occupancy, Rule 26 - exterior and, interior open space (except, R 26 (3) ), , Criteria, Constructions which are, deficient up to 15 %, (including tolerance as, specified in rule 20(3) of, the mandatory exterior and, interior open space as per, Rule will only be, considered for exemption., Constructions which, exceeds up to 5 % of the, permissible value as per, this rule will only be, considered for exemption, , 2, , Rule 27 - Coverage, , 3, , Rule 29- Parking, , Constructions which are, deficient up to 10 % of, the permissible value as, per this Rule will only be, considered for exemption, , 4, , Other Rules-R, 32(Mezzanine floor),R, 33(Height of rooms) R 34, (sanitation facilities),R 35, (1) (stair cases),R 35(2) (, fire escape stair case) 35, (3)-Ramp, R (37)-exit width, 38- doorways,R39corridor,R41 (2 to 6)- details, of light and ventilation, 43, , The authority for, exemption can consider, all other rules for, exemption taking in to, account the type of, construction and, condition of site,, subjected to a maximum, deviation of 10% of the, requirement., , Exemption Fee, 1) Deficient by 0-10% 10 times that of the, permit fee., 2) Above10 up to 15 %25 times that of permit, fee, , Fair value of land in, rupees per sqm multiplied, by additional plinth area, in, excess, of, that, permissible as per this rule, + Rs 8000 per sq m of, built up area in excess of, that permissible as per the, rule., Fair value of land in, rupees per sqm multiplied, by 15 sq m per parking, subject to a minimum of, Rs 3,00,000 per deficient, car parking, 15 times that of the, permit fee for each rule to, be exempted
Page 183 :
173, , (Other provisions for, apartment buildings),R, 44(Other provisions for, assembly buildings),R 45(other provisions regarding, Group G1 ), R 46-(other, provisions regarding Group, H ), R 49 (special provisions, for hut),R 50(special, provisions for construction, in small plot), R 51(special, provisions for row, buildings), Rules under, chapter VIII (provisions for, construction under approved, schemes), Rules under, chapter XI (Accessory, buildings and sheds), For all other rules not mentioned here, the respective rules will prevail
Page 184 :
174, , Appendix N, See rule 3(5), APPLICATION FOR EXEMPTION FROM BUILDING RULES, (to be submitted in duplicate), To, , The Secretary,, …………………….. Corporation / Municipality., I have obtained permit No. ……………………………. dated ....................................... for, , the construction or reconstruction or addition or alteration to an existing building with building, , no. ………………… in ................................................. Corporation / Municipality in Survey No., , ……………………………….. Village ………………………….. Taluk ………………………, District ……………………………. and have carried out the construction in deviation to plans, approved by the Secretary., , I realise that the construction so carried out is in violation of the provisions contained in the, , building rules and / or the Act and the date of commencement of the construction is, , ……………… and date of Completion of construction is ........................... I realize that the said, construction is an unauthorized one., , I request that sanction may be accorded for granting exemption of the said constructions from the, building rules. The application fee of …………………………………………… has been, remitted vide ............................................................................. Necessary documents and plans in, triplicate are enclosed., , The application details and checklist of the documents to be enclosed is given below:, 1, , Name of applicant (s), , 2, , Building Location, (i), , Ward No., , (ii), , Road / Street, , (iii), , Survey No. / Sub.Dn.No, , (iv), , Name of Village
Page 185 :
175, , (v), , Name of Block, , (vi), , Existing Building No. If any, , (vii), , Permit No. If any, , (viii), List of documents enclosed along with the application:, Receipt for payment of application fee, 1, 2, (i), (ii), (iii), (iv), (v), (vi), (vii), 3, (i), (ii), (iii), (iv), (v), 4, 5, , Three Copies of the drawings, Each of the floor Plans, Elevation, Section, Site Plan, Location Plan, Service Plan, Parking Plan, , Documents to prove ownership of land, Copy of land deed, Copy of Tax receipt, Copy of latest Possession Certificate, Copy of BTR certificate, Attested Copy of the survey sketch from revenue, department, Photo of Applicant (s) – affixed, 4 Photographs of Unauthorised Construction from all, four sides of the building showing all external details of, development – affixed and attested by owner(s) and, Licensee, , YES, , Submitted, NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA
Page 186 :
176, , 6, 7, 8, , 9, , Proof of valid registration of the licensee, Proof of qualification of the Structural Engineer who, has issued the structural stability certificate, Copies of the cases pending before or direction,, judgment etc., by Courts, Tribunal, Ombudsman etc., pertaining to or with reference to the plot or, constructions., Copies of any Government orders, Circulars any form, of communication against the plot / land or, constructions., , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , 10, , Copy of approved plans issued by the Secretary as per, the provisions contained in the Building rules, , YES, , NO, , NA, , 11, , Copy of building permit issued by the Secretary as per, the provisions contained in the Act or Building rules., , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , YES, , NO, , NA, , 12, 13, 14, 15, 16, , Copy of documentary evidence of the details of action, taken by the Municipal corporation / Municipality, against the unauthorised construction., Copy of the resolution made by all owners or their, association (for residential apartments), Copy of documentary evidence or any other details, pertaining to or relevant to the unauthorised, constructions and plot, Copy of Aadhar card of the owner, Any other documents submitted:, , (i), , (ii), Total No. of documents, , Signature of Applicant …………………………….., , Name of applicant (In Block letters)……………………………
Page 187 :
177, , SCHEDULE-I, , [[See rules 5(1), 15(6),70(4), 74(3),75(4)& 94], , (7), 10, , (8), 15, , Conversion of roof, (Rupees), , (6), 10, , Conversion of Erection, of Shutter or, door(Rupees), , Compound Wall(Rupees), , (5), 10, , Well(Rupees), , (4), 30, , Hut(Rupees), , (3), 30, , Building(Rupees), , (2), Panchayat, , Land development, (Rupees), , (1), 1, , Local Self Goverment, Institution, , Sl No, , APPLICATION FEE, , Note:- (1) No separate application or fee for land development is required along, with application for building permit except in cases specified otherwise in these rules., , (2) Separate application and fee is required only for the conversion or erection of, shutters or doors or roof in an existing building under rules 72 and 74(3)., , (9), 15
Page 188 :
1, Panchayat, Plot sub division including land developments, therein if any as per rule 31 (1), (2) & (3) (Rs., Per Ares of the land proposed for sub division), , Local Self Government Institution, , (1) (2), , Provided that in the case of residential buildings up to 150 sq. metres of built-up area, the permit, fee shall be only 50 percent of the amount mentioned above., 750, Other land developments(Rs. Per Hectares of the, land proposed for sub-division), , (3A), , 750, (4), , (i), , 7, , 10, , Thatched or tiled buildings –other than pucca, (Rupees per sq. metres of built-up area), , Pucca Building (Rupees per sq. metres of builtup area), , (3B), , 2, , Huts or sheds (Rupees per unit including their, accessory units if any), , (5), , 50, , Residential units for Economically Weaker, Sections funded by Government or Local Self, Government Institutions (Rupees per dwelling, unit), Wells (rupees per unit), , (6), (7), , NIL, , 20, , Roof conversion undue rules 72 and 74(3), (Rupees per sq. metre of built-up area), , (ii), , Shutter or door conversion or erection under, rules72 and74(3) (Rupees per unit), , (8) (9) (10), , Compound wall (Rupees per metre length), , Occupancies other, than group A1, , Group A1, Occupancy, , Sl. No, , 178, , SCHEDULE II, , [See Rules 9(4), 56(3),70(7), 74(3) & 75(4)], PERMIT FEE, , 3, , 300, , 3, , (11), , Note :- (1) Area of accessory building(s) such as car shed, toilet, cabin for watch and ward etc., shall be added to main building for calculating total permit fee. In the case of addition or, alteration, only the area of the portion added or altered shall be taken in to account., , (2) In the case of tourist resorts, the permit fee as stipulated in column (4) (ii) shall be, applicable irrespective of the structural conditions. The fee prescribed in column (5) or (6) shall, not be applicable in such cases.
Page 189 :
179, , SCHEDULE III, , [See rules 5(6)(2)], , SCRUTINY FEE FOR LAYOUT APPROVAL, , Occupancy Group, A1, A2,B,C, D,E,F, J, G1,G2, H,I, , Rate (Rupees /sq. metres of Built up area, 1, 2, 3, , The amount has to be remitted in Government treasury and the copy of the challan has to, be enclosed along with application for layout., , By order of the Governor,, , T. K. JOSE ,, , Additional Chief Secretary to Government., , Explanatory Note, , (This does not form part of the notification, but is intended to indicate its general purport), , The Kerala Panchayat Building Rules, 2011 was issued under G.O. (Ms.) No., 41/2011/LSGD dated 14th day of February, 2011 and published as S.R.O No. 127/2011 in the, Kerala Extraordinary No. 351 dated 14th day of February, 2011., Now the Government have decided to issue the Kerala Panchayat Building Rules, 2019, superseding the Kerala Panchayat Building Rules, 2011., The notification is intended to achieve the above object.